Data Quality Reports for Session: 150554 User: duansibo Completed: 06/03/2013


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070406.5FKB/GNDRAD/M1 - Instrument setup incorrect datafkbgndrad20sM1.a0, fkbgndrad60sM1.b1, fkbgndradM1.00
D071106.1FKB/GNDRAD/M1 - Reprocessed: Incorrect calibrationsfkbgndrad20sM1.a0, fkbgndrad60sM1.b1


DQRID : D070406.5
Start DateStart TimeEnd DateEnd Time
03/15/2007000003/29/20071727
Subject:
FKB/GNDRAD/M1 - Instrument setup incorrect data
DataStreams:fkbgndrad20sM1.a0, fkbgndrad60sM1.b1, fkbgndradM1.00
Description:
FKB station initial setup and configuration - all radiometer data before the end date of 
this time range is suspect. If this data is needed refer to DQ flags and manual assessment 
to determine if data is usable.
Measurements:fkbgndradM1.00:
  • Raw data stream - documentation not supported

fkbgndrad20sM1.a0:
  • base_time
  • alt
  • inst_up_long_hemisp_tp
  • inst_up_long_hemisp_dome_resist
  • inst_up_short_hemisp
  • time
  • lat
  • inst_sfc_ir_signal
  • lon
  • time_offset
  • inst_up_long_hemisp_case_resist

fkbgndrad60sM1.b1:
  • time
  • base_time
  • lat
  • Upwelling Longwave Hemispheric Irradiance, Unventilated Pyrgeometer, Minima(up_long_hemisp_min)
  • alt
  • Radiation, shortwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_short_hemisp)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • inst_up_long_hemisp_case_temp
  • up_short_hemisp_std
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Minima(up_short_hemisp_min)
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Maxima(up_short_hemisp_max)
  • sfc_ir_temp_std
  • Upwelling Longwave Hemispheric Irradiance, Unventilated Pyrgeometer, Maxima(up_long_hemisp_max)
  • vBatt
  • lon
  • up_long_hemisp_std
  • inst_up_long_hemisp_dome_temp
  • time_offset
  • Radiation, longwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_long_hemisp)
  • logger_temp
  • inst_up_long_hemisp_tp


Back To Table of Contents

DQRID : D071106.1
Start DateStart TimeEnd DateEnd Time
03/16/2007000011/05/20071344
Subject:
FKB/GNDRAD/M1 - Reprocessed: Incorrect calibrations
DataStreams:fkbgndrad20sM1.a0, fkbgndrad60sM1.b1
Description:
An incorrect calibration coefficient was applied to the up_short_hemispheric instrument 
(PSP) for the specified time period.  Changes in the ARM PSP calibration procedure now 
generates two different calibration coefficients for the same instrument, Cf(non "IR 
corrected")and Cfc("IR corrected").  CFc should have been applied to this instrument but CF was 
erroneously used.

The affected PSP is S/N 34292F3 Cf=117.61 (incorrect applied), Cfc(correct)=116.07W/m2/mV

These data were reprocessed and archived in March 2008.
Measurements:fkbgndrad20sM1.a0:
  • inst_up_short_hemisp

fkbgndrad60sM1.b1:
  • up_short_hemisp_std
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Minima(up_short_hemisp_min)
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Maxima(up_short_hemisp_max)
  • Radiation, shortwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_short_hemisp)


Back To Table of Contents



END OF DATA