DQR ID | Subject | Data Streams Affected |
---|---|---|
D040225.10 | SGP/TWR/C1 - Temperature Sensor Not Connected to Datalogger | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040304.30 | SGP/TWR/C1 - Southeast Side RH Too Large | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040830.4 | SGP/TWR/C1 - Tower SE-side lowered for maintenance | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D071217.2 | SGP/TWR/C1 - Southeast Side (10X) Temperature and RH Spikes | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1631 | 02/09/2004 | 1926 |
Subject: | SGP/TWR/C1 - Temperature Sensor Not Connected to Datalogger |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | One of the southeast side 25 m Temperature sensor leads was pulled out from the CR10X datalogger terminal strip. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/15/2003 | 1345 | 02/10/2004 | 2310 |
Subject: | SGP/TWR/C1 - Southeast Side RH Too Large |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The T/RH probes installed on the 25 m and 60 m levels of the southeast side of the tower on 8/15/03 gave RH readings that were too large for RH above 65%. The difference between the west and southeast side RH was within the combined accuracies of the sensors up to about 80% RH. Above 80% RH the southeast side RH was much larger, with the difference increasing to 10% larger (or more) at 100% RH. The vapor pressure from the southeast side (calculated with RH) was also too large. The probes were replaced on 2/10/04 and the two sides of the tower now agree fairly well, with RH not exceeding 100% during saturation. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/19/2003 | 2104 | 11/19/2003 | 2118 |
12/08/2003 | 1941 | 12/09/2003 | 1422 |
02/10/2004 | 1856 | 02/10/2004 | 2308 |
02/13/2004 | 1751 | 02/13/2004 | 2138 |
02/20/2004 | 1458 | 02/23/2004 | 1840 |
08/05/2004 | 1412 | 08/05/2004 | 1451 |
09/27/2004 | 1438 | 09/27/2004 | 2056 |
02/14/2006 | 2002 | 02/14/2006 | 2105 |
05/31/2006 | 1756 | 05/31/2006 | 1852 |
10/11/2006 | 1446 | 10/11/2006 | 2039 |
07/26/2007 | 1340 | 07/26/2007 | 1900 |
08/20/2007 | 1450 | 08/20/2007 | 1555 |
Subject: | SGP/TWR/C1 - Tower SE-side lowered for maintenance |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The southeast side tower carriage was lowered for maintenance and/or data are off-scale during maintenance. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/04/2007 | 1700 | 01/24/2008 | 2030 |
Subject: | SGP/TWR/C1 - Southeast Side (10X) Temperature and RH Spikes |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | Southeast side 25 m and 60 m (10X datastreams) carriage connectors may not have been well connected; temperatures and relative humidities spiked sometimes. This problem occurred after the carriages were lowered on 12/04. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|