DQR ID | Subject | Data Streams Affected |
---|---|---|
D000202.2 | SGP/OKM/X1 - Station PRES decommissioned and removed from service | sgp05okmX1.a1, sgp15okmX1.a1, sgp05okmX1.00, sgp15okmX1.00, sgp15okmX1.b1, sgp05okmX1.b1, sgpokmX1.01 |
D000330.4 | SGP/OKM Overview of Automated QA - January 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
D000330.5 | SGP/OKM Overview of Automated QA - February 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
D000419.1 | SGP/OKM Overview of Automated QA - March 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
D000524.1 | SGP/OKM Overview of Automated QA - April 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
D000712.1 | SGP/OKM Overview of Automated QA - May 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
D000809.1 | SGP/OKM Overview of Automated QA - June 2000 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D000905.1 | SGP/OKM Overview of Automated QA - July 2000 | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
D001005.1 | SGP/OKM - Overview of Automated Data Quality - August 2000 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D001102.1 | SGP/OKM - Overview of Automated Data Quality - September 2000 | sgp15okmX1.a1, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.b1 |
D001207.22 | SGP/OKM - Overview of Automated Data Quality - October 2000 | sgp15okmX1.a1, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.b1 |
D010104.1 | SGP/OKM - Overview of Automated Data Quality - November 2000 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.b1, sgp15okmX1.a1 |
D010214.1 | SGP/OKM - Overview of Automated Data Quality - December 2000 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.b1, sgp15okmX1.a1 |
D010320.18 | SGP/OKM - Overview of Automated Data Quality -January 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.b1, sgp15okmX1.a1 |
D010412.2 | SGP/OKM - Overview of Automated Data Quality - February 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010510.1 | SGP/OKM - Overview of Automated Data Quality - March 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010531.3 | SGP/OKM - CATO station retired | sgp15okmX1.b1, sgp05okmX1.b1, sgpokmX1.01 |
D010531.4 | SGP/OKM - BEEX station added | sgp15okmX1.b1, sgp05okmX1.b1, sgpokmX1.01 |
D010531.6 | SGP/OKM - Overview of Automated Data Quality - April 2001 | sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.b1, sgp05okmX1.a1 |
D010703.1 | SGP/OKM - Overview of Automated Data Quality - May 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010731.1 | SGP/OKM - Overview of Automated Data Quality - June 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010906.1 | SGP/OKM - Overview of Automated Data Quality - July 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D011015.1 | SGP/OKM - Overview of Automated Data Quality - August 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D011127.3 | SGP/OKM - Overview of Automated Data Quality - September 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020131.1 | SGP/OKM/X1 - Overview of Automated Data Quality - October 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020131.2 | SGP/OKM/X1 - Overview of Automated Data Quality - November 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020201.1 | SGP/OKM/X1 - Overview of Automated Data Quality - December 2001 | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
D031016.1 | SGP/OKM/X1 - Station Change | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
D031016.2 | SGP/OKM/X1 - Station Change | sgp30okmX1.01, sgp30okmX1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/19/1996 | 0000 | 01/20/2000 | 2359 |
Subject: | SGP/OKM/X1 - Station PRES decommissioned and removed from service |
DataStreams: | sgp05okmX1.a1, sgp15okmX1.a1, sgp05okmX1.00, sgp15okmX1.00, sgp15okmX1.b1, sgp05okmX1.b1, sgpokmX1.01 |
Description: | The station PRES (Preston) was installed on June 19, 1996 for a grant funded project and removed on January 20, 2000 when the project terminated because it is close to other stations and because it was a frequent victim of vandals. |
Measurements: | sgp15okmX1.00:
sgpokmX1.01:
sgp15okmX1.a1:
sgp05okmX1.00:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2000 | 0000 | 01/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - January 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the January 2000 Oklahoma Mesonet data. Date Station Parameter(s) ---- ------- ------------ 1/07 BBOW WS2M Completely calm conditions at this site caused the wind speed at 2 m to stay at 0 m/s all day. Although the data was flagged by the persistence test, it is ok. 1/12 BUFF TAIR Cold air drainage caused this site to be much colder than neighboring sites. Ignore the flags. 1/13 BUFF TAIR Cold air drainage caused this site to be much colder than neighboring sites. Ignore the flags. 1/26 BBOW WS2M Completely calm conditions at this site caused the wind speed at 2 m to stay at 0 m/s all day. Although the data was flagged by the persistence test, it is ok. 1/27 CHIC TA9M ---| ELRE RELH | Continuous light snow GUTH RELH | caused the parameters at these MARE RELH | sites to stay constant MARS RELH | all day long. They failed our PERK TA9M | persistence test. You can SPEN RELH | disregard the flags. STIL TA9M | ACME TAIR | ACME TA9M ---| --------------------------------------------------------------- OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of January, 2000 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =============================================================== Notes: The Preston site was removed on 20 January due to repeated vandalism that has occurred there. Other vandalism incidents: 4 January: A149 TAIR and RELH sensor damaged 16 January: CHIC WS2M stolen and datalogger damaged Many improvements were made in January to our soil moisture data. 6 stations had their faulty sensors replaced or repaired during the month. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: #4338 MARS Sensor reporting 180 degrees out of phase on numerous occasions Added: None Resolved: None WSPD Current: None Added: #4832 EUFA Sensor consistently 1-2 m/s slower than WS2M and is local minimum compared to neighbors Resolved: None PRES Current: #4118 CHEY No barometer hole drilled, sensor is detecting pressure inside enclosure #4680 BBOW Observed 32 barometer errors, probably a lose wire #4801 MTHE Observed 75 barometer errors, probably a lose wire Added: None Resolved: None SRAD Current: None Added: #4831 MIAM PM SRAD is consistently 50 W/m^2 higher than neighbors Resolved: None RAIN Current: None Added: #4830 ANTL Site received double the rainfall as neighbors in January. Gauge may be double- tipping again. Resolved: None TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #4769 CHIC Replaced stolen sensor TS10 Current: #4818 STIG Sensor has 15 C warm bias Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: None Added: #4834 FORA Sensor does not agree with other soil levels Resolved: None TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: #3147 TIPT Corrected wiring problem ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: #4670 A149 Replaced vandalized sensor RELH Current: None Added: None Resolved: #4669 A149 Replaced vandalized sensor SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.00:
sgp15okmX1.a1:
sgp05okmX1.00:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2000 | 0000 | 02/29/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - February 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the February 2000 Oklahoma Mesonet data. ============================================================== OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of February, 2000 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =============================================================== Notes: OASIS 2000 for the northeast quadrant of the state began February 22. OASIS 2000 is an NCAR in-field comparison with our OASIS stations. As part of normal maintenance, the Mesonet Technicians installed updated datalogger operating systems at 24 stations during February. The remainder of the sites will be updated during March. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: #4338 MARS Replaced to correct WDIR errors WSPD Current: #4862 NEWK Data indicates low bias #4863 WOOD Data indicates low bias Added: None Resolved: #4832 EUFA Replaced sensor with bad bearings; causing low wspds #4859 SEIL Replaced sensor with bad bearings; causing low wspds #4864 STIG Replaced sensor with bad bearings; causing low wspds #4865 CHEY Replaced sensor with bad bearings; causing low wspds PRES Current: None Added: None Resolved: #4680 BBOW Re-tightened wires to correct barometer errors #4800 BOWL Re-tightened wires to correct barometer errors #4801 MTHE Restripped/Re-tightened wires to correct barometer errors #4833 PUTN Reset logger to correct baro- meter stuck at 0.0 mb #4842 FREE Reset logger to correct baro- meter stuck at 0.0 mb #4866 CHEY Reset logger to correct baro- meter stuck at 0.0 mb SRAD Current: #4831 MIAM PM SRAD is consistently 50 W/m^2 higher than neighbors Added: None Resolved: None RAIN Current: None Added: None Resolved: #4830 ANTL Replaced cable, logger, and wiring panel to correct double- tipping TA9M Current: #4873 WEAT Sensor stuck at -273.1 C Added: None Resolved: None WS2M Current: None Added: None Resolved: #4870 CHIC Replaced dead sensor TS10 Current: None Added: None Resolved: #4818 STIG Replaced sensor with gopher damage TB10 Current: None Added: None Resolved: None TS05 Current: #4834 FORA Sensor does not agree with other soil levels Added: None Resolved: #4875 STIG Replaced sensor that failed in-field comparison TB05 Current: #4872 WYNO Corrected erosion problem Added: None Resolved: None TS30 Current: None Added: None Resolved: #4876 STIG Replaced sensor that failed in-field comparison ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: #4874 A133 Gauge under-reporting rainfall Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.00:
sgp15okmX1.a1:
sgp05okmX1.00:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2000 | 0000 | 03/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - March 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the March 2000 Oklahoma Mesonet data. There are a few special events in the March Mesonet data that you may want to be aware of. These include: Date Station Parameter(s) ---- ------- ------------ 3/03 CLOU WMAX Gust to 89 mph during severe thunderstorm; you can disregard the automated QA flag 3/02 ARNE PRES Mesolow caused ARNE to be spatially inconsistent with neighboring sites; disregard the automated QA flags =============================================================== OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of March, 2000 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =============================================================== Notes: One last ice storm... Mother Nature coated much of western Oklahoma with freezing rain on March 16-17, causing upwards of 40 wind monitors to freeze solid. These observations were flagged in Qualparm to indicate their suspicious readings. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: None Added: #4927 WASH Monthly QA indicates 1 C high TDEW bias Resolved: None WDIR Current: None Added: None Resolved: #4890 TISH Repaired sensor stuck at 355 degrees WSPD Current: #4863 WOOD Data indicates low bias Added: None Resolved: #4862 NEWK Bearings found noisy and replaced nose cone PRES Current: None Added: #4920 ACME Monthly QA indicates 1 mb high bias #4921 JAYX Monthly QA indicates 1 mb high bias Resolved: None SRAD Current: None Added: #4924 WIST Monthly QA indicates 50 W/m^2 low bias #4925 COPA Monthly QA indicates 75 W/m^2 low bias #4926 MIAM Monthly QA continues to indicates 50 W/m^2 high bias Resolved: #4831 MIAM Replaced sensor to correct high bias RAIN Current: None Added: #4923 JAYX Check for possible clog Resolved: #4901 FTCB Replaced reed switch that was causing gauge to be stuck at 0. TA9M Current: #4902 BYAR Sensor reporting 6 C cool bias Added: None Resolved: #4873 WEAT Replaced bad logger port to correct TA9M problem WS2M Current: None Added: None Resolved: #4879 NORM Corrected bent boom TS10 Current: #4915 WEST Sensor warmer than TS05 in the afternoon Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: #4916 WEST Sensor cooler than TS10 in the afternoon Added: None Resolved: #4834 FORA Replaced sensor with cool bias TB05 Current: #4872 WYNO Erosion problem over bare plot Added: #4922 ANTL Possible erosion due to high afternoon bias #4928 MEDF Possible erosion due to high afternoon bias Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: #4874 A133 Fixed loose wire TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.00:
sgp15okmX1.a1:
sgp05okmX1.00:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2000 | 0000 | 04/30/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - April 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the April 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians are beginning their Spring Pass of all Mesonet and ARS stations. All sites will be visited over the next 2 months to perform routine maintenance, along with point data comparisons of many parameters. In addition, site photos are being taken to document ground cover and a new procedure is being performed to recalibrate our site elevations via test barometers. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: #4947 ELRE Sensor reporting over 106% during high humidity #4948 MAYR Sensor dropping to 0% Added: None Resolved: #4927 WASH Replaced sensor with 1 C high TDEW bias WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #4863 WOOD Replaced sensor suspected of low bias PRES Current: #4940 FTCB Sensor stuck at 956.0 mb Added: None Resolved: #4920 ACME Barometer tested ok, site elevation recalibrated #4921 JAYX Barometer tested ok, site elevation recalibrated SRAD Current: None Added: None Resolved: #4924 WIST Replaced sensor with low bias #4925 COPA Replaced sensor with low bias #4926 MIAM Replaced sensor with high bias RAIN Current: None Added: None Resolved: #4923 JAYX Removed debris from funnel TA9M Current: None Added: None Resolved: #4902 BYAR Replaced sensor and removed mud-dobber nest from shield WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #4914 SEIL Corrected wiring problem #4915 WEST Corrected wiring problem TB10 Current: None Added: None Resolved: #4913 SEIL Corrected wiring problem #4944 ANTL Corrected erosion problem TS05 Current: #4953 SALL Check for possible wiring problem Added: None Resolved: #4916 WEST Corrected wiring problem TB05 Current: #4928 MEDF Possible erosion due to high afternoon bias Added: None Resolved: #4872 WYNO Corrected erosion problem #4922 ANTL Corrected erosion problem TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: #4903 A110 Replaced rusty switch #4908 A135 Replaced stuck switch TS05 Current: None Added: None Resolved: None TS10 Current: #4949 A151 Sensor jumping erratically from -273 to 70 C Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.00:
sgp15okmX1.a1:
sgp05okmX1.00:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2000 | 0000 | 05/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - May 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgp05okmX1.00, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians continued site visits during May as part of "Spring Pass 2000". All stations will have received maintenance by the end of June. A cow broke through the enclosure at JAYX on May 12. I've been meaning to tell Ken Meyers I found somebody looking like they were up to no good at the nearby Pryor site: http://radar.metr.ou.edu/cgi-bin/sitephoto.cgi?site=pryo&dir=ne&info=photos Do you think we have our first suspect? (That link comes from our online site photo gallery accessible through the main Mesonet web page at http://okmesonet.ocs.ou.edu.) ================================================================ TAIR Current: #5011 SLAP Sensor reporting -7999 during most observations Added: None Resolved: #4965 JAYX Replaced cow-damaged sensor RELH Current: #4948 MAYR Sensor dropping to 0% #5006 CAMA Sensor reported near 0% RH intermittently #5010 SLAP RELH to 105% #5013 ARDM Sensor reporting over 103% #5014 ALV2 RELH to 108% Added: None Resolved: #4947 ELRE Replaced sensor reporting over 106% #4964 JAYX Replaced cow-damaged sensor WDIR Current: None Added: None Resolved: None WSPD Current: #4976 BYAR Sensor sporadically 4-5 m/s slower than speed at 9 m Added: None Resolved: #4993 CHIC Replaced noisy bearings #5023 ALTU Replaced noisy bearings PRES Current: #4980 RETR Sensor dropped 100 mb on May 18-19 Added: None Resolved: #4940 FTCB Replaced barometer stuck at 956.03 mb SRAD Current: #5009 SLAP Sensor reporting below 0 Added: #5072 KETC Monthly QA indicates 5-10% high bias Resolved: None RAIN Current: None Added: None Resolved: #4962 JAYX Repaired broken wire on cable #4988 TAHL Replaced failed switch #5026 ALTU Replaced intermittently failing switch TA9M Current: #5008 SLAP Sensor reporting below 0 Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5007 SLAP Sensor has 6 C warm bias Added: None Resolved: #4982 SALL Replaced gopher-damaged sensor TB10 Current: None Added: None Resolved: #4968 NORM Reset depth indicator; sensor was 1 cm high #4984 SALL Repaired erosion; sensor was 2 cm high TS05 Current: None Added: None Resolved: None TB05 Current: None Added: None Resolved: #4928 MEDF Corrected erosion problem #4965 NORM Reset depth indicator; sensor was 1 cm high #4985 SALL Repaired erosion; sensor was 2 cm high TS30 Current: #5005 CHIC Sensor stuck at -273.1 Added: None Resolved: #4983 SALL Replaced gopher-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: #4970 A161 Repaired loose wire RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: #5071 A136 Monthly QA indicates 3-4 C warm bias Resolved: None TS30 Current: None Added: None Resolved: #4966 A131 Replaced sensor with warm bias ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.00:
sgp15okmX1.a1:
sgp05okmX1.00:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/2000 | 0000 | 06/30/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - June 2000 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the June 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians completed Spring Pass 2000 on June 30. The point comparisons they performed on the TAIR, RELH, PRES, SRAD, and RAIN parameters were very useful for QA of Mesonet data. A number of sensors reporting slightly outside of the Mesonet's acceptable error ranges were identified. Many site photos were taken during Spring Pass 2000 to document vegetation cover around the bare and sod soil temperature plots, the soil heat flux sensors, and the soil moisture plots at each station. Look for those pictures along with the site visitation forms indicating the technician's notes to be available on the web next month. One more note... The monthly analysis for June identified the very heavy rains that fell over east Oklahoma during mid to late June. Westville took top honors with a June total of 17.04 inches! ================================================================ TAIR Current: None Added: None Resolved: #5011 SLAP Replaced malfunctioning sensor RELH Current: #5014 ALV2 RELH to 108% #5074 WIST RELH to 112% #5082 ADAX Sensor found to be 6% high during Spring Pass 2000 comparison #5083 BBOW Sensor found to be 20% high during Spring Pass 2000 comparison #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison #5102 KENT Sensor stuck at 0% for extended period Added: None Resolved: #4948 MAYR Replaced bad sensor #5006 CAMA Replaced bad sensor #5010 SLAP Replaced bad sensor #5013 ARDM Replaced sensor that failed mesocomp #5077 WEST Replaced sensor stuck at 0% #5087 CENT Replaced sensor found to have 5.3% high bias during spring pass 2000 #5094 MARE Replaced sensor found to have 5.9% high bias during spring pass 2000 #5110 BUFF Replaced sensor found to have 6.0% high bias during spring pass 2000 WDIR Current: None Added: None Resolved: None WSPD Current: #4976 BYAR Sensor sporadically 4-5 m/s slower than speed at 9 m Added: None Resolved: #5093 MARE Replaced sensor with noisy bearings #5120 CLAR Replaced sensor with noisy bearings PRES Current: #5086 RETR Sensor found to be .72 mb high during Spring Pass 2000 comparison Added: None Resolved: #4980 RETR Found tube clogged with bug #5046 WIST Replaced bad barometer SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5079 WASH Sensor found to be 23% high during Spring Pass 2000 comparison #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison Added: None Resolved: #5009 SLAP Corrected SRAD problems by replacing bad RH switch RAIN Current: #5078 BURN Gauge recorded no rain during radar-indicated rain event #5098 BESS Gauge found to be double-tipping on one side of bucket during Spring Pass 2000 test Added: None Resolved: #5075 PUTN Replaced bad switch TA9M Current: None Added: None Resolved: #5008 SLAP Corrected TA9M problems by cleaning corroded negative ground WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5007 SLAP Corrected TS10 problems by cleaning corroded negative ground #5056 SKIA Tightened down power ground port TB10 Current: #5096 BOWL Sensor reports 10 C warm bias during and after rain events Added: None Resolved: #5057 SKIA Tightened down power ground port TS05 Current: None Added: None Resolved: #5058 SKIA Tightened down power ground port TB05 Current: None Added: None Resolved: #5059 SKIA Tightened down power ground port TS30 Current: #5005 CHIC Sensor stuck at -273.1 Added: None Resolved: #5012 SALL Replaced sensor reporting unreasonable values #5060 SKIA Tightened down power ground port ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5092 A181 Gauge recorded no rain during heavy rain event Added: None Resolved: #5055 A133 Repaired vandalized gauge TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: #5071 A136 Monthly QA indicates 3-4 C warm bias Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2000 | 0000 | 07/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - July 2000 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | =============================================================== Notes: The Mesonet Technicians have begun Summer Pass 2000. All sites will be visited between July 15 and September 30. In addition to the routine maintenance that will be performed at each site, many new site photos (including updated panoramic photos) will be taken. Lightning, lightning, lightning... "The July Victims": (1) Fairview (2) Seiling (3) Grandfield (4) Medford base (5) Blackwell base (6) Kiowa Repeater (twice) ================================================================ TAIR Current: None Added: None Resolved: #5100 BEAV Replaced after found to be 0.59 C high during Spring Pass #5102 KENT Sensor found to be dangling from mount #5112 BOIS Replaced after found to be 0.7 C warm during Spring Pass #5113 PUTN Replaced after found to be 0.8 C warm during Spring Pass #5123 CLOU Replaced after found to be 0.6 C warm during Spring Pass #5134 PAWN Replaced bad sensor RELH Current: #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison #5140 MAYR Sensor reported to 108% Added: None Resolved: #5014 ALV2 Replaced after sensor rose to 108% RH #5073 SLAP Replaced after sensor reported erratic dips to 5-10% RH #5074 WIST Replaced after sensor rose to 112% RH #5076 HOOK Replaced after sensor sporadically dipped to 0%. #5082 ADAX Replaced after sensor found to be 6% high during Spring Pass #5083 BBOW Replaced after sensor found to be 20% high during Spring Pass #5085 KENT Repaired sensor found to be dangling from mount #5116 BYAR Replaced after sensor found to be 5.5% high during Spring Pass #5121 IDAB Replaced after sensor found to be 7.2% high during Spring Pass #5122 MTHE Replaced after sensor found to be 8% high during Spring Pass #5124 PERK Replaced after sensor found to be 5.1% high during Spring Pass #5126 SULP Replaced after sensor found to be 7.9% high during Spring Pass WDIR Current: None Added: None Resolved: #5167 SEIL Replaced lightning-damaged sensor WSPD Current: None Added: None Resolved: #4976 BYAR Replaced sensor with loose nut #5117 BYAR Replaced sensor with loose nose cone prop #5130 MINC Replaced nose cone due to bad bearings #5151 CENT Replaced sensor due to noisy bearings #5152 LANE Replaced sensor due to noisy bearings #5153 WIST Replaced sensor due to noisy bearings #5154 WILB Replaced sensor due to noisy bearings #5155 TALI Replaced sensor due to noisy bearings #5156 STUA Replaced sensor due to slightly noisy bearings PRES Current: #5086 RETR Sensor found to be .72 mb high during Spring Pass 2000 comparison Added: None Resolved: #5136 SALL Replaced barometer tube found to be plugged by critter SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5079 WASH Sensor found to be 23% high during Spring Pass 2000 comparison #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5078 BURN Gauge recorded no rain during radar-indicated rain event #5098 BESS Gauge found to be double-tipping on one side of bucket during Spring Pass 2000 test #5114 CHEY Gauge found to over-report by 6.25% during Spring Pass drip test Added: #5185 TIPT Long term analysis indicates possible under-reporting Resolved: #5142 KING Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset Added: None Resolved: #5096 BOWL Replaced sensor with 10 C warm bias TB10 Current: #5179 SALL TB10 is warmer than TB05 during all times of the day Added: None Resolved: None TS05 Current: None Added: None Resolved: #5127 ANTL Sensor found to be angled upward #5128 BRIS Corrected wiring problem TB05 Current: None Added: None Resolved: #5129 KING 1-2 inches of grass clippings removed from bare plot TS30 Current: None Added: None Resolved: #5005 CHIC Replaced wiring problem ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5092 A181 Replaced bad switch #5104 A130 Replaced bad switch #5105 A149 Replaced bad switch TS05 Current: None Added: #5181 A132 Monthly QA indicates 4 C warm bias during all times of day Resolved: #5132 A136 Replaced gopher-damaged sensor #5149 A161 Replaced gopher-damaged sensor TS10 Current: None Added: #5182 A167 Monthly QA indicates 4 C warm bias during all times of day Resolved: #5131 A136 Replaced gopher-damaged sensor TS15 Current: None Added: None Resolved: #5071 A136 Replaced gopher-damaged sensor #5139 A137 Replaced reporting frequent data spikes TS30 Current: #5157 A165 Reporting erratic observations Added: None Resolved: #5137 A161 Cable chewed in half and sensor stolen ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/2000 | 0000 | 08/31/2000 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - August 2000 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 2000 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: None RELH Current: #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison Added: None Resolved: #5140 MAYR Replaced sensor exceeding 103% WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #5158 MADI Replaced sensor due to noisy bearings #5195 SALL Replaced sensor due to noisy bearings PRES Current: None Added: None Resolved: #5086 RETR Replaced sensor with high bias SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: #5079 WASH Replaced sensor with high bias RAIN Current: #5208 MTHE Gauge double-tipping on one side Added: None Resolved: #5078 BURN Removed spider web that was clogging gauge #5098 BESS Replaced gauge that was found to be double-tipping on one side of bucket during Spring Pass 2000 test #5162 TAHL Replaced gauge that was found to be double-tipping #5183 CHAN Replaced suspect switch #5184 BOWL Replaced switch found to be double-tipping #5185 TIPT Replaced gauge despite 4 success- ful drip tests because site has had longest dry period #5188 VINI Replaced gauge found to be double-tipping on one side #5202 SKIA Replaced gauge found to double- tip occasionally TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #5141 DURA Replaced sensor reporting constant 0 m/s TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset #5199 DURA Sensor reporting sporadically and 8 C warm Added: None Resolved: None TB10 Current: None Added: None Resolved: #5179 SALL Replaced bad sensor #5200 GRA2 Repaired cracked ground over bare plot TS05 Current: #5194 FAIR Sensor has 5 C cool bias since lightning strike Added: None Resolved: None TB05 Current: #5187 DURA Sensor stuck at -273.1 C Added: None Resolved: #5201 GRA2 Repaired cracked ground over bare plot TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: #5181 A132 Monthly QA indicates 4 C warm bias during all times of day #5203 A167 Sensor reporting erratically and has 10 C warm bias Added: None Resolved: None TS10 Current: #5182 A167 Monthly QA indicates 4 C warm bias during all times of day Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: #5157 A165 Reporting erratic observations Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/2000 | 0000 | 09/30/2000 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - September 2000 |
DataStreams: | sgp15okmX1.a1, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the September 2000 Oklahoma Mesonet data. =============================================================== TAIR Current: None Added: None Resolved: #5239 PUTN Fixed broken excitation wire on TAIR sensor RELH Current: None Added: #5264 WEBB Monthly QA indicates 5-10% high bias Resolved: #5084 WAUR Replaced sensor found to be biased 7% high during mesocomp WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #5241 VINI Replaced sensor with noisy bearings #5242 WYNO Replaced sensor with noisy bearings PRES Current: None Added: None Resolved: None SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: #5079 WASH Replaced sensor with high bias RAIN Current: None Added: None Resolved: #5228 GOOD Replaced bad gauge #5253 CALV Replaced suspect gauge #5208 MTHE Replaced suspect gauge TA9M Current: None Added: None Resolved: #5206 CLAY Replaced damaged gauge #5240 PUTN Fixed broken excitation wire WS2M Current: None Added: None Resolved: None TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset Added: None Resolved: #5199 DURA Repaired AG wire TB10 Current: #5216 PUTN Sensor erratic and dropping to as low as -17.2 C Added: None Resolved: None TS05 Current: #5194 FAIR Sensor has 5 C cool bias since lightning strike Added: None Resolved: None TB05 Current: #5215 PUTN Sensor erratic and dropping to as low as -87.5 C Added: None Resolved: #5193 PERK Replaced bad sensor #5187 DURA Replaced bad sensor TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5232 A150 Defective switch Added: None Resolved: #5237 A138 Replaced bad switch #5238 A136 Replaced bad switch TS05 Current: #5243 A136 Sensor frequently drops to -273.1 C Added: #5265 A135 Data very noisy Resolved: #5181 A132 Replaced bad sensor #5203 A167 Replaced sensor with 9 C bias TS10 Current: None Added: #5267 Possible 3 C cool bias Resolved: #5214 A132 Replaced sensor with bad insulation TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: #5157 A165 Replaced bad sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/2000 | 0000 | 10/31/2000 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - October 2000 |
DataStreams: | sgp15okmX1.a1, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the October 2000 Oklahoma Mesonet data. TAIR Current: #5323 TIPT Sensor has 6 C high bias Added: None Resolved: None RELH Current: #5293 CATO Reporting 105% or higher #5316 WEBB Reporting 40% low bias Added: #5332 MEDI Monthly QA indicates 5% high bias Resolved: #5264 WEBB Replaced sensor with 5-10% high bias WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5297 BREC Under-reported rain event Added: None Resolved: #5272 BLAC Replaced bad switch #5277 STIL Gauge checked and no problem found after apparent under-reporting #5278 BRIS Removed spider web that prevented gauge from tipping #5296 KETC Replaced bad gauge #5314 ACME Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset #5281 FTCB Stuck at -273.1 C Added: None Resolved: #5279 BIXB Sensor found to have 1 C cool bias TB10 Current: #5216 PUTN Sensor erratic and dropping to as low as -17.2 C #5282 FTCB Stuck at -273.1 Added: None Resolved: #5261 WEST Repaired excitation wire TS05 Current: #5194 FAIR 5 C cool bias #5283 FTCB Stuck at -273.1 C Added: None Resolved: #5262 BRIS Sensor found to have 5 C cool bias #5263 BIXB Sensor found to have 2 C warm bias TB05 Current: #5215 PUTN Sensor erratic and dropping to as low as -87.5 C #5284 FTCB Stuck at -273.1 C Added: None Resolved: None TS30 Current: #5285 FTCB Stuck at -273.1 C #5301 WASH 9 C warm bias Added: None Resolved: #5273 APAC Replaced gopher-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: #5180 A182 Replaced sensor with 2.5 C warm bias RELH Current: None Added: None Resolved: None SRAD Current: #5255 A151 Mesocomp found 6% difference #5294 A166 Stuck at 1 W/m^2 Added: None Resolved: None RAIN Current: #5319 A182 Dramatically over-estimates rainfall Added: #5325 A156 Gauge appears to have over- reported #5324 A151 Gauge stuck at 0 during rain event Resolved: #5295 A155 Replaced switch found to be double tipping #5232 A150 Replaced defective switch TS05 Current: None Added: None Resolved: #5243 A136 Replaced defective sensor #5265 A135 Replaced sensor reporting erratically TS10 Current: #5267 A111 Possible 3 C cool bias Added: None Resolved: #5266 A165 Corrected wiring problem TS15 Current: #5318 A167 Stuck at -90 C Added: None Resolved: None TS30 Current: None Added: None Resolved: #5157 A165 Replaced bad sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2000 | 0000 | 11/30/2000 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - November 2000 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.b1, sgp15okmX1.a1 |
Description: | DQR DESCRIPTION: Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the November 2000 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: #5323 TIPT Replaced sensor with high bias RELH Current: #5332 MEDI Monthly QA indicates 5% high bias Added: None Resolved: #5293 CATO Replaced sensor with 5% high bias #5316 WEBB Replaced suspect sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5297 BREC Under-reported rain event Added: None Resolved: None TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5178 MADI Replaced suspect sensor #5281 FTCB Repaired lose wire TB10 Current: #5216 PUTN Sensor erratic and dropping to as low as -17.2 C Added: None Resolved: #5282 FTCB Repaired lose wire TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: #5283 FTCB Repaired lose wire TB05 Current: #5215 PUTN Sensor erratic and dropping to as low as -87.5 C Added: None Resolved: #5284 FTCB Repaired lose wire TS30 Current: #5301 WASH 9 C warm bias Added: None Resolved: #5285 FTCB Repaired lose wire ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #5294 A166 Replaced bad sensor RAIN Current: None Added: None Resolved: #5319 A182 Replaced corroded switch #5324 A151 Replaced bad switch #5325 A156 Replaced corroded switch TS05 Current: None Added: None Resolved: #5326 A182 Replaced gopher-damaged sensor TS10 Current: None Added: None Resolved: #5267 A111 Replaced sensor with 2 C cool bias TS15 Current: None Added: None Resolved: #5318 A167 Replaced sensor found chewed in half TS30 Current: None Added: None Resolved: #5299 A159 Replaced erratic sensor #5300 A182 Replaced erratic sensor #5334 A167 Replaced sensor found chewed in half ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2000 | 0000 | 12/31/2000 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - December 2000 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.b1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the December 2000 Oklahoma Mesonet data. Notes: 2 ice storms in December caused many QA problems in the Mesonet. The storm that occurred on Christmas day was the most severe. That particular event caused the wind sensors to be frozen in place at 84 stations for anywhere from 1 to 11 days straight! In addition, the ice coated temperature and RH shields, pyranometers, and rain gauges. The ice also made roads impassable for techs who tried to repair communi- cation links that were knocked out due to ice damage. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5332 MEDI Monthly QA indicates 5% high bias #5355 ERIC Sensor frequently drops to 0% Added: None Resolved: None WDIR Current: #5344 SKIA Sensor stuck at 360 Added: None Resolved: None WSPD Current: #5392 ACME Sensor reported gust to over 35 m/s during ice storm Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: #5394 SEIL Sensor reporting 80% low Resolved: None RAIN Current: #5396 NORM Gauge under-estimated during precip event #5397 MEDF Gauge stuck at 0 during precip event #5398 CLOU Gauge stuck at 0 during precip event Added: None Resolved: #5297 BREC Replaced bad switch #5354 LANE Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: None Added: #5402 MAYR 3 C cool bias Resolved: #5216 PUTN Repaired lose wire on mux TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: None TB05 Current: None Added: None Resolved: #5215 PUTN Repaired lose wire on mux TS30 Current: None Added: None Resolved: #5301 WASH Replaced sensor with warm bias ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5395 A150 Sensor recorded no tips during snow melt Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2001 | 0000 | 01/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality -January 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.b1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the January 2001 Oklahoma Mesonet data. A major ice storm took place from January 28-30 across the northwest one-third of Oklahoma. The wind sensors became frozen at over 40 stations. Several occurrences in which soil temperature sensors have "heaved" themselves out of the ground have been noted by techs recently. After analyzing the soil temperature data for January, it appears that 9 additional stations may be having the same problem. Trouble tickets have been issued so that the suspect sites can be visited during this coming month. The unusually wet and cold winter is likely to blame. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5355 ERIC Sensor frequently drops to 0% Added: None Resolved: #5332 MEDI Replaced sensor with suspected 5% high bias WDIR Current: None Added: None Resolved: #5344 SKIA Replaced sensor stuck at 360 degrees WSPD Current: None Added: None Resolved: #5405 PAUL Replaced suspect sensor PRES Current: None Added: None Resolved: #5403 VINI Replaced barometer reporting +300 mb high bias SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: #5394 SEIL Sensor reporting 80% low Resolved: None RAIN Current: #5397 MEDF Gauge stuck at 0 during precip event Added: None Resolved: #5351 STIL Replaced gauge with bad switch #5396 NORM Replaced suspect gauge #5398 CLOU Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: #5402 MAYR 3 C cool bias Added: None Resolved: None TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: None TB05 Current: #5416 REDR Possible erosion causing TB05 to drop well below freezing #5419 MARS Possible erosion causing TB05 to drop well below freezing Added: #5454 BLAC Possible erosion #5455 KING Possible erosion #5456 OKMU Possible erosion #5457 PRYO Possible erosion #5458 FORA Possible erosion #5459 TAHL Possible erosion Resolved: #5215 PUTN Repaired lose wire on mux TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5395 A150 Repaired gauge by adjusting switch TS05 Current: None Added: #5453 A165 Possible erosion Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2001 | 0000 | 02/28/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - February 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the February 2001 Oklahoma Mesonet data. 3 more ice storms hit the state during February. The first storm lasted from the 8th through the 11th and affected much of northwest Oklahoma. The second event lasted from the 15th through the 18th and affected 27 stations in south-central and east-central Oklahoma. The third event affected over 40 stations in central and northeastern Oklahoma on the 28th of the month. Wind data from these events was flagged appropriately in the QA database. HUGO became the first site to get struck by lightning during 2001. On the 24th, the site suffered major damage to the logger, battery, rain gauge, temperature and RH, and soil temperatures sensors. =============================================================== TAIR Current: #5442 GRA2 Sensor reporting 3.5 C warm bias Added: None Resolved: None RELH Current: #5505 HUGO Lightning damage Added: None Resolved: #5355 ERIC Replaced erratic sensor #5441 HECT Repaired lose wire WDIR Current: None Added: None Resolved: None WSPD Current: #5490 RING Bad bearings suspected due to low bias Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 #5394 SEIL Sensor reporting 80% low Added: #5519 MEDF Monthly QA indicates 10% low bias Resolved: None RAIN Current: #5397 MEDF Gauge stuck at 0 during precip event #5511 HUGO Gauge occasionally double-tips #5466 PUTN Gauge under-reported rainfall by over 1 inch Added: None Resolved: None TA9M Current: #5492 JAYX Reporting 7-8 erratic obs per day Added: None Resolved: None WS2M Current: None Added: None Resolved: #5445 WAUR Replaced dirty bearings TS10 Current: #5507 HUGO Lightning damage Added: None Resolved: #5410 SKIA Tightened lose wire TB10 Current: #5402 MAYR 3 C cool bias #5468 STUA Sensor has 10 C warm bias Added: #5518 MEDF Monthly QA indicates 3 C warm bias Resolved: #5433 SHAW Reset sensor found heaved upward #5479 HASK Reset sensor found heaved upward TS05 Current: #5194 FAIR 5 C cool bias #5508 HUGO Lightning damage Added: None Resolved: None TB05 Current: #5419 MARS Possible erosion causing TB05 to drop well below freezing #5454 BLAC Possible erosion #5455 KING Possible erosion #5456 OKMU Possible erosion #5457 PRYO Possible erosion #5458 FORA Possible erosion #5459 TAHL Possible erosion Added: None Resolved: #5416 REDR Reset sensor found heaved upward #5417 SHAW Reset sensor found heaved upward #5480 HASK Reset sensor found heaved upward TS30 Current: #5509 HUGO Lightning damage Added: #5517 EUFA Monthly QA indicates 3 C cool bias Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: #5516 A149 Monthly QA indicates high bias Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5467 A121 Gauge under-reporting Added: None Resolved: #5452 A122 Replaced bad switch TS05 Current: #5453 A165 Possible erosion Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2001 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - March 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the March 2001 Oklahoma Mesonet data. 69 trouble tickets were resolved by the techs during March. WOW! You won't notice all of that work here in this report, because some of the fixes were for scheduled rotations of sensors and work done on OASIS sensors (both of which we haven't made a part of the monthly QA report as of yet.) Soil temperature probes under bare soil continue to be a major problem as over 20 stations have been found to have their probes literally heaved out of the ground. This is something we've never witnessed in the Mesonet EVER, and is likely due to all the wet, freezing weather we had this past winter. We'll hope it doesn't happen again for at least 8 more years. The Mesonet technicians are beginning their Spring Pass 2001 in which all sites will be visited over the next 3 months. During this pass, they will be taking site photos, maintaining the vegetation inside the site enclosure, cleaning sensors, and performing rain gauge tests. =============================================================== TAIR Current: None Added: None Resolved: #5442 GRA2 Replaced faulty sensor RELH Current: None Added: None Resolved: #5505 HUGO Replaced lightning-damaged sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #5490 RING Replaced damaged sensor PRES Current: None Added: None Resolved: None SRAD Current: #5519 MEDF Monthly QA indicates 10% low bias Added: None Resolved: #5072 KETC Replaced sensor with high bias #5159 FAIR Replaced lightning-damaged sensor #5394 SEIL Replaced sensor with low bias RAIN Current: #5511 HUGO Gauge occasionally double-tips Added: None Resolved: #5397 MEDF Replaced bad switch #5466 PUTN Replaced bad switch TA9M Current: None Added: None Resolved: #5492 JAYX Repaired lose wire WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5507 HUGO Replaced lightning-damaged sensor TB10 Current: #5518 MEDF Monthly QA indicates 3 C warm bias Added: None Resolved: #5402 MAYR Replaced bad sensor #5468 STUA Replaced gopher-damaged sensor #5440 WILB Corrected erosion problem TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: #5508 HUGO Replaced lightning-damaged sensor TB05 Current: #5515 STIG Sensor reporting erratic values Added: #5569 CATO Check for erosion #5570 BREC Check for erosion Resolved: #5419 MARS Repaired erosion problem #5454 BLAC Repaired erosion problem #5455 KING Repaired erosion problem #5456 OKMU Repaired erosion problem #5457 PRYO Repaired erosion problem #5458 FORA Site checked for erosion #5459 TAHL Repaired erosion problem #5499 TISH Repaired erosion problem #5535 BIXB Repaired erosion problem #5536 WYNO Repaired erosion problem #5537 COPA Repaired erosion problem #5538 NOWA Repaired erosion problem #5539 MIAM Repaired erosion problem #5541 WILB Repaired erosion problem TS30 Current: #5517 EUFA Monthly QA indicates 3 C cool bias Added: None Resolved: #5509 HUGO Replaced lightning-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: #5522 A152 Repaired vandalized sensor RELH Current: None Added: None Resolved: #5516 A149 Replaced sensor with high bias SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5467 A121 Replaced bad switch TS05 Current: None Added: None Resolved: #5453 A165 Checked for erosion TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #5523 A165 Corrected wiring problem TS30 Current: None Added: None Resolved: #5524 A165 Corrected wiring problem ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 04/19/2001 | 2359 |
Subject: | SGP/OKM - CATO station retired |
DataStreams: | sgp15okmX1.b1, sgp05okmX1.b1, sgpokmX1.01 |
Description: | The Catoosa station (CATO) was decommissioned on April 19 due to poor site exposure and the end of the EPSCOR project. |
Measurements: | sgpokmX1.01:
sgp05okmX1.b1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/OKM - BEEX station added |
DataStreams: | sgp15okmX1.b1, sgp05okmX1.b1, sgpokmX1.01 |
Description: | A new site located at Bee (BEEX) was added beginning on April 1, 2001. It does not appear in data files before that date. |
Measurements: | sgpokmX1.01:
sgp05okmX1.b1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 04/30/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - April 2001 |
DataStreams: | sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.b1, sgp05okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the April 2001 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: #5525 HUGO Replaced erratic sensor RELH Current: None Added: None Resolved: None WDIR Current: #5590 BURB Sensor reporting out of phase Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5588 BBOW Replaced plugged-up barometer SRAD Current: None Added: None Resolved: #5519 MEDF Replaced sensor with low bias RAIN Current: None Added: None Resolved: #5511 HUGO Replaced gauge that occasionally double tips #5592 HASK Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #5623 BBOW Replaced sensor with noisy bearings TS10 Current: #5589 BURB Sensor has erratic 10 C warm bias Added: None Resolved: #5556 EUFA Replaced suspect sensor TB10 Current: None Added: None Resolved: #5518 MEDF Replaced sensor with 3 C warm bias #5553 NORM Repaired erosion problem #5558 EUFA Replaced suspect sensor TS05 Current: None Added: None Resolved: #5194 FAIR Replaced lightning-damaged sensor #5557 EUFA Replaced suspect sensor TB05 Current: None Added: None Resolved: #5515 STIG Replaced erratic sensor #5547 NORM Repaired erosion problem #5559 EUFA Replaced suspect sensor #5570 BREC Repaired erosion problem TS30 Current: None Added: None Resolved: #5517 EUFA Replaced suspect sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ====================================================================== |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2001 | 0000 | 05/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - May 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 2001 Oklahoma Mesonet data. ============================================================== Notes: Rotations of the wind speed sensors are coming to a close. Most all Mesonet sites have had their nose cones replaced. Pyranometers are now beginning to be rotated statewide. Most stations should have newly calibrated pyranometers by the end of the summer. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5639 NINN Sensor reporting many small spikes and dips not observed at nearby A122 #5707 ALTU Sensor stuck at 10-15% Added: None Resolved: None WDIR Current: None Added: None Resolved: #5590 BURB Repaired erroneous WDIR by fixing TA15 port WSPD Current: None Added: None Resolved: #5673 CALV Replaced sensor with noisy bearings PRES Current: None Added: None Resolved: #5644 CLAY Replaced bad barometer SRAD Current: None Added: None Resolved: None RAIN Current: #5666 GOOD Gauge missed rain event Added: None Resolved: #5662 BURB Replaced bad switch #5698 CLAY Replaced bad switch TA9M Current: #5658 MIAM Sensor reporting 20 C cool bias Added: None Resolved: None WS2M Current: None Added: None Resolved: #5664 MARE Replaced sensor with noisy bearings #5670 EUFA Replaced sensor with noisy bearings #5676 CALV Replaced sensor with noisy bearings #5685 CLAY Replaced sensor with dirty bearings TS10 Current: None Added: None Resolved: #5589 BURB Repaired erratic readings by fixing TA15 port TB10 Current: #5665 APAC Sensor reporting 10 C warm bias Added: None Resolved: None TS05 Current: None Added: None Resolved: None TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5669 B123 Gauge reported rain in excess of 8 inches Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: #5671 A125 New sensor (installed via trouble ticket #5634) is also reporting erratic obs Added: None Resolved: #5634 A125 Replaced bad sensor TS15 Current: None Added: None Resolved: None TS30 Current: None Added: #5727 A135 Monthly QA indicates 4 C cool bias Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ====================================================================== |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/2001 | 0000 | 06/30/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - June 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the June 2001 Oklahoma Mesonet data. ============================================================== Notes: Spring Pass 2001 was completed in June. All 114 stations have now been visited, inspected, and maintained. In addition, over 1500 digital photos were taken to document the vegetation conditions at each site. The technicians now embark on Summer Pass 2001... =============================================================== TAIR Current: None Added: None Resolved: #5724 SALL Replaced bad sensor RELH Current: #5772 STIL Sensor stuck at 0% Added: None Resolved: #5639 NINN Replaced erratic sensor #5707 ALTU Replaced bad sensor WDIR Current: None Added: None Resolved: #5723 FREE Replaced defective sensor WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5769 HECT Initial installation of barometer SRAD Current: None Added: None Resolved: #5702 OILT Replaced bad sensor #5851 FREE Replaced lightning-damaged sensor RAIN Current: #5778 STIL Double counts on one bucket Added: None Resolved: #5746 JAYX Fixed clogged gauge #5776 CLAR Repaired stuck buckets #5758 LANE Fixed double-tipping gauge #5771 MEDF Cleaned clogged gauge #5708 COPA Replaced suspect gauge #5666 GOOD Removed spider that was preventing buckets from tipping TA9M Current: None Added: None Resolved: #5658 MIAM Tightened wires to sensor WS2M Current: #5857 MADI Stuck at 0 Added: None Resolved: #5784 STIL Replaced sensor with noisy bearings TS10 Current: None Added: None Resolved: None TB10 Current: #5885 DURA Many erratic data dips Added: None Resolved: #5762 WIST Corrected erosion problem #5764 TALI Corrected erosion problem #5665 APAC Replaced defective sensor TS05 Current: #5756 SLAP Sod is consistently warmer than bare plot #5858 HOLL Sod is consistently warmer than bare plot Added: None Resolved: None TB05 Current: #5859 ARDM Data suggests sensor is sticking out of ground Added: None Resolved: #5761 WIST Corrected erosion problem #5763 TALI Corrected erosion problem TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #5714 A156 Replaced lightning-damaged sensor SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5669 B123 Replaced defective switch TS05 Current: None Added: None Resolved: #5725 A111 Replaced defective sensor TS10 Current: None Added: None Resolved: #5671 A125 Replaced defective sensor TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: #5726 A135 Replaced defective sensor #5717 A134 Replaced defective sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2001 | 0000 | 07/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - July 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the July 2001 Oklahoma Mesonet data. Notes: Northwest and southwest Oklahoma were the hot spots of the state during July. Average 1800 UTC temperatures in those areas were over 36 C (97 F). The 1800 UTC pressure data revealed corresponding localized areas of low pressure (heat lows) in those same areas. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #5772 STIL Replaced bad sensor #5950 BRIS Replaced bad sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5898 VANO Initial install of barometer SRAD Current: None Added: None Resolved: #5927 MARS Replaced sensor with high bias #6002 BUTL Replaced sensor with low bias RAIN Current: #6006 GOOD Soil moisture detected rainfall, but gauge did not Added: None Resolved: #5778 STIL Fixed double-counting gauge TA9M Current: None Added: None Resolved: #5658 MIAM Tightened wires to sensor WS2M Current: None Added: None Resolved: #5870 WEBB Replaced sensor with noisy bearings #5877 NEWK Replaced sensor with high starting threshold #5857 MADI Replaced dead sensor TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: #5885 DURA Tightened wire to correct erratic data TS05 Current: #5756 SLAP Sod is consistently warmer than bare plot Added: None Resolved: #5858 HOLL Corrected erosion problem TB05 Current: #5859 ARDM Data suggests sensor is sticking out of ground Added: None Resolved: #5859 ARDM Replaced sensor with high bias TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #5983 A133 Replaced sensor with high bias RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #5909 A166 Replaced defective sensor #5966 A130 Replaced sensor with 6 C warm bias TS10 Current: #6000 A148 Sensor spiking to 50 C #6001 A125 Sensor spiking to 70 C Added: None Resolved: #5926 A159 Replaced gopher-damaged sensor #5910 A125 Replaced defective sensor TS15 Current: None Added: None Resolved: #5956 A159 Replaced gopher-damaged sensor #5963 A125 Replaced defective sensor #5965 A155 Replaced defective sensor TS30 Current: #5998 A130 Sensor dipping below 0 C #5999 A154 Sensor has a 10 C cool bias #6004 A122 Sensor reporting erratically and out of range Added: None Resolved: #5726 A135 Replaced defective sensor #5717 A134 Replaced defective sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/2001 | 0000 | 08/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - August 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 2001 Oklahoma Mesonet data. ============================================================== Notes: Mesonet technicians were busy performing Summer Pass 2001 during August. Just a few of their tasks include: trimming vegetation, cleaning sensors, rotating sensors, and performing sensor tests. Summer Pass will be completed October 1. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: #6036 ALTU Reporting multiple data dips #6053 MARE Reporting multiple data spikes Added: None Resolved: None SRAD Current: #6081 FAIR Reporting values over 600 W/m^2 at night Added: None Resolved: None RAIN Current: None Added: None Resolved: #6033 OKMU Replaced bad switch #6034 CLAR Replaced bad switch #6050 CHER Cleaned dirty gauge TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: #6054 CHAN Sod plot is 4 C warmer than bare plot #6064 ADAX TS05 is consistently cooler than TS10 Added: None Resolved: None TB05 Current: None Added: None Resolved: #6055 ALV2 Repaired erosion TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #6023 A181 Replaced lightning-damaged sensor RAIN Current: None Added: None Resolved: #6017 A154 Replaced bad switch #6018 A132 Replaced suspect switch #6030 A162 Replaced suspect switch TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #6000 A148 Replaced bad sensor #6001 A125 Replaced bad sensor TS15 Current: None Added: None Resolved: #6015 A154 Replaced damaged sensor TS30 Current: None Added: None Resolved: #5998 A130 Replaced defective sensor #5999 A154 Replaced defective sensor #6004 A122 Replaced dead sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/2001 | 0000 | 09/30/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - September 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the September 2001 Oklahoma Mesonet data. ============================================================== Notes: The Mesonet technicians completed Summer Pass 2001 in late September. Just a few of their accomplishments during this pass include: * 1500 site photos taken to document the stations * 95 sensors rotated * All rain gauges tested * All soil temperature depths verified =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #6036 ALTU Replaced erratic barometer #6053 MARE Removed obstructions from baro tube SRAD Current: None Added: None Resolved: #6081 FAIR Replaced bad pyranometer RAIN Current: None Added: None Resolved: #6082 ADAX Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #6089 ALTU Replaced due to bad bearings #6104 IDAB Replaced due to bad bearings TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #6064 ADAX Replaced bad sensor TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/2001 | 0000 | 10/31/2001 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - October 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the October 2001 Oklahoma Mesonet data. ============================================================== TAIR Current: None Added: None Resolved: #6130 BEEX Replaced suspect sensor #6133 RING Replaced suspect sensor RELH Current: None Added: #6187 SEIL Monthly QA indicates 5% high bias Resolved: #6149 MADI Replaced erratic sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #6157 ANTL Replaced noisy sensor PRES Current: None Added: None Resolved: #6164 KETC Corrected wiring problem SRAD Current: None Added: None Resolved: #6109 OKEM Cleaned heavily soiled sensor #6163 BLAC Leveled sensor RAIN Current: None Added: None Resolved: #6152 ALV2 Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: #6165 TISH Sensor reports frequent data dips Added: None Resolved: None TS05 Current: #6146 FAIR Sensor stuck at -46 C Added: None Resolved: #6054 CHAN Removed gopher mound TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6144 A144 Replaced stolen gauge #6145 A162 Removed spider web from bucket TS05 Current: None Added: None Resolved: #6108 A121 Replaced erratic sensor TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #6126 A134 Replaced bad sensor TS30 Current: None Added: None Resolved: #6107 A165 Replaced gopher-damaged sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2001 | 0000 | 11/30/2001 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - November 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the November 2001 Oklahoma Mesonet data. ============================================================== Notes: A new Mesonet site located near Inola, OK was installed on 14 November 2001. The new station's 4-letter identifier is INOL. This site measures all of the core Mesonet parameters. Bill Wyatt and Thomas Smith completed the rotation of all wind monitors in the northwest section of the state during November. ============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #6181 REDR Replaced suspect sensor #6187 SEIL Replaced suspect sensor #6188 CHER Replaced sensor reaching 103-106% during periods of high relative humidity WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #6192 WIST Replaced erratic pyranometer RAIN Current: #6231 COOK Gauge continued to report tips after snow melt #6232 BEEX Gauge stuck at 0 for rain events Added: None Resolved: #6191 CHER Replaced gauge that failed drip test #6207 MINC Replaced rusty screws on terminal strip that caused missing tips TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: #6254 RING Monthly QA indicates 2 C cool bias Resolved: None TB10 Current: None Added: None Resolved: #6165 TISH Tightened wires that had caused erratic observations TS05 Current: #6146 FAIR Sensor stuck at -46 C Added: None Resolved: None TB05 Current: None Added: None Resolved: #6206 WASH Corrected 1 cm of soil erosion TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6208 A133 Removed spider web that prevented tips from occurring TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2001 | 0000 | 12/31/2001 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - December 2001 |
DataStreams: | sgp05okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Janet Martinez, the Mesonet QA manager of the automated quality assurance results for the December 2001 Oklahoma Mesonet data. ============================================================== Notes: The Mesonet Technicians completed the Fall Pass 2001 in late December. Over 1800 site photos were taken. We are preparing a CD that will contain all photos, accomplishments, site visitation forms and special findings. The CD will be available next month. The Technicians also resolved 59 trouble tickets in December! In addition to the tickets shown in this report, their work included scheduled rotations of wind monitors and soil temperature sensors, as well as replacements of site batteries and rain gauge switches. The monthly analysis identified the site with the maximum rainfall. Mt. Herman received 11.8 inches in December, with 7.8 inches falling in a single day (December 16)! In late November, a widespread freezing rain event impacted southern and eastern Oklahoma. The wind data from 27 stations were deemed erroneous and appropriately flagged in the database. ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #6259 RETR Frequent erratic dips in data Added: None Resolved: #6260 PAUL Replaced sensor reaching 114% relative humidity WDIR Current: None Added: None Resolved: #6261 KENT Fixed wiring problem #6262 BOIS Fixed wiring problem #6263 GOOD Fixed wiring problem #6264 HOOK Fixed wiring problem #6265 BEAV Fixed wiring problem WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: RAIN Current: None Added: None Resolved: #6192 COOK Replaced switch #6232 BEEX Removed spider webs that prevented tips from occurring #6266 TALI Removed spider webs that prevented tips from occurring TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #6230 APAC Replaced sensor with dips to -100 C #6254 RING Replaced suspect sensor TB10 Current: None Added: None Resolved: None TS05 Current: None Added: #6304 WAUR Monthly QA indicates 3 C cool bias Resolved: #6252 INOL Fixed wiring on sensor reporting -219.3 C #6282 RING Replaced suspect sensor TB05 Current: None Added: None Resolved: #6268 ARDM Re-leveled surface to correct depth TS30 Current: None Added: #6305 MANG Monthly QA indicates 5 C cool bias Resolved: #6283 RING Replaced suspect sensor ------------------------------------------------------------------------ ARS QA REPORT ------------------------------------------------------------------------ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6257 A163 Replaced switch on gauge that failed drip test #6270 A156 Removed webbing between funnel and buckets #6302 A154 Replaced switch on gauge that failed drip test TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #6258 A110 Replaced sensor damaged by rodent TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 09/28/2003 | 2359 |
Subject: | SGP/OKM/X1 - Station Change |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | The Mesonet station near Marshall was moved on September 25, 2003 to improve accessiblity for the Mesonet technicians who visit and maintain the site. The new site has the code MRSH. It replaces the old Marshall site that had the code MARS. Since the latitude and longitude of the stations are included in the cdf file, users of these data should not have a problem. |
Measurements: | sgpokmX1.01:
sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1998 | 0000 | 09/24/2003 | 2359 |
Subject: | SGP/OKM/X1 - Station Change |
DataStreams: | sgp30okmX1.01, sgp30okmX1.b1 |
Description: | The Mesonet station near Marshall was moved on September 25, 2003 to improve accessiblity for the Mesonet technicians who visit and maintain the site. The new site has the code MRSH. It replaces the old Marshall site that had the code MARS. Since the latitude and longitude of the stations are included in the cdf file, users of these data should not have a problem. |
Measurements: | sgp30okmX1.01:
sgp30okmX1.b1:
|