DQR ID | Subject | Data Streams Affected |
---|---|---|
D060707.1 | GEC/SUOMI/X1 - Temperature Sensor Failure at Site SA42 (Manus Island) | gec30suomigpsX1.c1 |
D060707.2 | GEC/SUOMI/X1 - Temperature, RH Sensor Failure at Site SG27 (Barrow) | gec30suomigpsX1.c1 |
D060707.3 | GEC/SUOMI/X1 - Temperature/Relative Humidity/Pressure Sensors Not Reporting at Site SA39 (Darwin) | gec30suomigpsX1.c1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/26/2005 | 0930 | 10/16/2006 | 0200 |
Subject: | GEC/SUOMI/X1 - Temperature Sensor Failure at Site SA42 (Manus Island) |
DataStreams: | gec30suomigpsX1.c1 |
Description: | The temperature sensor failed at this location causing it to read -51 degC constantly. This resulted in a bias in the retrieved precipitable water vapor (PWV) of approximately 1 cm (low). |
Measurements: | gec30suomigpsX1.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/26/2005 | 1600 | 07/03/2006 | 0000 |
Subject: | GEC/SUOMI/X1 - Temperature, RH Sensor Failure at Site SG27 (Barrow) |
DataStreams: | gec30suomigpsX1.c1 |
Description: | The temperature and relative humidity sensors failed at this location, causing the temperature to read -51 degC and the RH to read 100% constantly. This results in a bias in the retrieved precipitable water vapor (PWV). |
Measurements: | gec30suomigpsX1.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/20/2006 | 1800 | 05/24/2006 | 2300 |
Subject: | GEC/SUOMI/X1 - Temperature/Relative Humidity/Pressure Sensors Not Reporting at Site SA39 |
DataStreams: | gec30suomigpsX1.c1 |
Description: | During this period at the Darwin site (SA39) the meteorological sensors (temperature, relative humidity, and pressure) were not reporting. This results in missing or incorrect retrievals of precipitable water vapor (PWV). |
Measurements: | gec30suomigpsX1.c1:
|