DQR ID | Subject | Data Streams Affected |
---|---|---|
D000210.2 | SGP/EBBR - EBBR E19 Changeout, Data Missing/Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D000221.4 | SGP/EBBR - EBBR E19 Wind Speed Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D000301.2 | SGP/EBBR - EBBR E19 Net Radiation Incorrect | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
D010213.6 | SGP/EBBR/E19 - EBBR E19 Wind Speed Iced | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
D010427.4 | SGP EBBR E19 - E19 EBBR Left RH Probe Temperature Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D010427.5 | SGP EBBR E19 - E19 EBBR Left Aspirator Housing Off | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D010427.6 | SGP EBBR E19 - E19 EBBR Left Air Temperature Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D010427.7 | SGP EBBR E19 - E19 EBBR Data Incorrect During J-panel Replacement | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D010427.8 | SGP EBBR E19 - E19 EBBR Wind Direction Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D011102.8 | SGP EBBR E19 - E19 EBBR Wind Speed Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D011127.30 | SGP EBBR E19 - E19 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D020716.15 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D020717.29 | SGP/EBBR/E19 - Most Measurements Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.30 | SGP/EBBR/E19 - All Measurements Zero | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.31 | SGP/EBBR/E19 - Pressure Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D020717.32 | SGP/EBBR/E19 - Measurements Incorrect After CR10 Replacement | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.33 | SGP/EBBR/E19 - Low Battery Voltage | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D030110.24 | SGP/EBBR/E19 - Data Incorrect during 6 month checks | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D030116.11 | SGP/EBBR/E19 - Water in Net Radiometer Dome | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030116.6 | SGP/EBBR/E19 - Incorrect data after power interruption | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030116.7 | SGP/EBBR/E19 - Most Measurements Zero following Restart | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030117.1 | SGP/EBBR/E19 - Pressure Low | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030117.6 | SGP/EBBR/E19 - Measurements zero following logger restart | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030711.12 | SGP/EBBR/E19 - All Data Zeros | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030711.20 | SGP/EBBR/E19 - Many Measurements Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030712.20 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030919.10 | SGP/EBBR/E19 - Water in Net Radiometer; Surface Fluxes are Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030922.6 | SGP/EBBR/E19 - Tair Right Offscale | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D031110.8 | SGP/EBBR/E19 - Battery Voltage Too Low, Most Measurements Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D031117.2 | SGP/EBBR/E19 - AEM Stuck In One Position, Surface Fluxes Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D031124.11 | SGP/EBBR/E19 - Data Missing During Recalibration Changeout | sgp15ebbrE19.b1, sgp30baebbrE19.c1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgpebbrE19.00, sgpebbrE19.01 |
D031204.17 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D031204.18 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D031204.2 | SGP/EBBR/E19 - Data All Zeros | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D031204.3 | SGP/EBBR/E19 - Most Data Incorrect | sgp5ebbrE19.b1 |
D040106.1 | SGP/EBBR/E19 - Wind Speed Sensor Frozen Stopped by Ice Storm | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040206.4 | SGP/EBBR/E19 - Low Battery Voltage Caused Incorrect Data | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040304.26 | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D040407.2 | SGP/EBBR/E19 - Reprocess: Incorrect Net Rad Calibration Coefficient | sgp30baebbrE19.c1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040525.4 | SGP/EBBR/E19 - Metadata errors | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040525.5 | SGP/EBBR/E19 - Metadata errors | sgp5ebbrE19.b1 |
D040608.7 | SGP/EBBR/E19 - AEM Hung Inbetween Home Positions | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D041222.15 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050206.13 | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050207.9 | SGP/EBBR/E19 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050215.20 | SGP/EBBR/E19 - Wind Speed Constant | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050324.2 | SGP/EBBR/E19 - Reprocess: Negative Net Rad calibrations | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050624.3 | SGP/EBBR/E19 - Net Radiation Incorrect - Cable Chewed by Rodents | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D051112.1 | SGP/EBBR/E19 - metadata corrections | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D051214.2 | SGP/EBBR/E19 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D051214.3 | SGP/EBBR/E19 - Incorrect Sensible and Latent Heat Fluxes | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D080527.2 | SGP/EBBR/E19 - Sensible and latent heat flux and net radiation incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D090313.4 | SGP/EBBR/E19 - Wind Speed Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D100202.3 | SGP/EBBR/E19 - Wind direction sensor frozen near north | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D100203.1 | SGP/EBBR/E19 - Wind speed sensor frozen stopped | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D111004.2 | SGP/EBBR/E19 - Nighttime data missing | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D980110.1 | SGP/EBBR/E19 - Battery Voltage Drop | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D980110.2 | SGP/EBBR/E19 - Noisy Sensible and Latent Heat Fluxes | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D980117.18 | SGP/EBBR/E19- EBBR Frozen Wind Speed | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D980416.15 | SGP/EBBR/E19 - 3-Month Check | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D980529.13 | SGP/EBBR/E19 - Six-Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D990127.24 | SGP/EBBR/E19 - Wind Direction Data Incorrect (revised) | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D990127.35 | SGP/EBBR/E19 - Wind Speed Data Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00, sgp15ebbrE19.b1 |
D990127.36 | SGP/EBBR/E19 - Wind Speed Data Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D990409.9 | SGP/EBBR/E19 - Net Radiation Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D990421.4 | SGP/EBBR/E19 - Incorrect Tref, Tair Data, Bowen Ratio, latent and sensible heat fluxes | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D990622.3 | SGP/EBBR/E19 - Temperature of Left Humidity Probe Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/20/1999 | 1430 | 07/20/1999 | 1830 |
Subject: | SGP/EBBR - EBBR E19 Changeout, Data Missing/Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | During changeout of the EBBR system at E19, data was missing for the time period, except for 1815-1830 GMT, when the data was incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/31/2000 | 2245 | 02/02/2000 | 1640 |
Subject: | SGP/EBBR - EBBR E19 Wind Speed Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The anemometer cups were frozen stalled during the period. The following values were therefore incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/09/1999 | 0330 | 12/16/1999 | 1630 |
Subject: | SGP/EBBR - EBBR E19 Net Radiation Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiometer top dome was broken and water had entered. Net radiation values are therefore incorrect during the period. The affected data are: 5 minute: q 15 minute: mv_q 30 minute: q, h, e |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/25/2000 | 1245 | 12/28/2000 | 1815 |
Subject: | SGP/EBBR/E19 - EBBR E19 Wind Speed Iced |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/1999 | 0030 | 12/02/1999 | 1631 |
Subject: | SGP EBBR E19 - E19 EBBR Left RH Probe Temperature Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The Left RH probe temperature was drifting. The indicated measurements are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/2000 | 1500 | 12/08/2000 | 1946 |
Subject: | SGP EBBR E19 - E19 EBBR Left Aspirator Housing Off |
DataStreams: | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The left aspirator housing fell off and thus the indicated measurements are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/07/1999 | 0000 | 02/24/2000 | 1601 |
Subject: | SGP EBBR E19 - E19 EBBR Left Air Temperature Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | A bad capacitor on the J-panel caused left air temperature, and thus other measurements to be incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/09/2000 | 1630 | 03/09/2000 | 1701 |
Subject: | SGP EBBR E19 - E19 EBBR Data Incorrect During J-panel Replacement |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The indicated data was incorreect during a J-panel replacement. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2000 | 2030 | 12/13/2000 | 0731 |
Subject: | SGP EBBR E19 - E19 EBBR Wind Direction Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The wind direction sensor was frozen stopped during the indicated period. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2001 | 0300 | 03/01/2001 | 1651 |
Subject: | SGP EBBR E19 - E19 EBBR Wind Speed Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The wind speed sensor was iced stopped for a while on this day. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/03/2001 | 1413 | 10/03/2001 | 1506 |
04/19/2001 | 1700 | 04/19/2001 | 2001 |
Subject: | SGP EBBR E19 - E19 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2002 | 1430 | 05/16/2002 | 1501 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/2002 | 0430 | 04/08/2002 | 0431 |
05/19/2002 | 0400 | 05/19/2002 | 0401 |
Subject: | SGP/EBBR/E19 - Most Measurements Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | Most measurements were incorrect for the indicated periods. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/27/2002 | 1500 | 06/27/2002 | 1501 |
04/18/2002 | 1730 | 04/18/2002 | 1731 |
05/05/2002 | 1400 | 05/05/2002 | 1401 |
Subject: | SGP/EBBR/E19 - All Measurements Zero |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | Measurements are often zero the first period after a CR10 restart. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/29/2002 | 1830 | 05/29/2002 | 1831 |
04/24/2002 | 1600 | 04/24/2002 | 2201 |
05/29/2002 | 2000 | 05/29/2002 | 2001 |
06/15/2002 | 1900 | 06/15/2002 | 1901 |
05/25/2002 | 2200 | 05/25/2002 | 2231 |
05/25/2002 | 2100 | 05/25/2002 | 2101 |
05/29/2002 | 1730 | 05/29/2002 | 1731 |
05/29/2002 | 2130 | 05/29/2002 | 2131 |
05/30/2002 | 1500 | 05/30/2002 | 1501 |
Subject: | SGP/EBBR/E19 - Pressure Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The pressure measurement was incorrect. This is used to determine the Bowen ratio, thereby affecting the sensible and latent heat fluxes also. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2002 | 2000 | 05/17/2002 | 0531 |
Subject: | SGP/EBBR/E19 - Measurements Incorrect After CR10 Replacement |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | Replacement of the CR10 datalogger caused most measurements to be incorrect, reason unknown. A different logger was installed at the end of the specified period and this resolved the problem. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/27/2002 | 0000 | 06/02/2002 | 1031 |
Subject: | SGP/EBBR/E19 - Low Battery Voltage |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | A battery voltage of less than 10.5 causes many of the sensors to produce incorrect measurements. The 15 minute data contains the battery voltage and should be used to determine whether the measurements are usable, based on battery voltage. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2002 | 1600 | 11/14/2002 | 1630 |
Subject: | SGP/EBBR/E19 - Data Incorrect during 6 month checks |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/25/2002 | 2100 | 09/05/2002 | 1430 |
Subject: | SGP/EBBR/E19 - Water in Net Radiometer Dome |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiation measurement is incorrect. Measurements calculated using net radiation are also incorrect. No work-around is possible for this situation. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 1600 | 07/11/2002 | 1629 |
Subject: | SGP/EBBR/E19 - Incorrect data after power interruption |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Most measurements are suspect after a power outage, caused by replacement of the solar panel regulator. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 1500 | 07/11/2002 | 1529 |
Subject: | SGP/EBBR/E19 - Most Measurements Zero following Restart |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/17/2002 | 1430 | 10/31/2002 | 1600 |
Subject: | SGP/EBBR/E19 - Pressure Low |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The barometric pressure sensor read about 10 mb low during this period because a lead from the sensor was loose or disconnected. The error does not affect any other measurements. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1700 | 01/09/2003 | 1729 |
Subject: | SGP/EBBR/E19 - Measurements zero following logger restart |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. The restart on 01/09/03 occurred after J-panel replacements. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1700 | 01/09/2003 | 1700 |
02/06/2003 | 1730 | 02/06/2003 | 1730 |
04/03/2003 | 1830 | 04/03/2003 | 1830 |
Subject: | SGP/EBBR/E19 - All Data Zeros |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | All data (5, 15, and 30 minute) was zero after replacement of sensors and restart of the CR10. This is a common occurrence. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/15/2003 | 1600 | 05/15/2003 | 1700 |
Subject: | SGP/EBBR/E19 - Many Measurements Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect during replacement of a multiplexer. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2003 | 1440 | 05/01/2003 | 1515 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/30/2003 | 1400 | 09/04/2003 | 1445 |
Subject: | SGP/EBBR/E19 - Water in Net Radiometer; Surface Fluxes are Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/17/2003 | 1830 | 09/17/2003 | 2000 |
09/17/2003 | 2230 | 09/18/2003 | 0100 |
Subject: | SGP/EBBR/E19 - Tair Right Offscale |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The right air temperature data were going offscale. This affected the calculation of sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/03/2003 | 2000 | 11/13/2003 | 1615 |
Subject: | SGP/EBBR/E19 - Battery Voltage Too Low, Most Measurements Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Battery voltage dropped below levels required to sustain the production of valid data. The AC charger unit had failed. This prevented charging of the battery during the night and prevented the solar panel regulator from properly charging the battery during the day. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2003 | 2115 | 11/26/2003 | 1600 |
Subject: | SGP/EBBR/E19 - AEM Stuck In One Position, Surface Fluxes Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The AEM home 15 and 30 outputs were both 40 mv because the AEM was not exchanging. Sensible and Latent Heat Fluxes are therefore incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1505 | 10/10/2003 | 1755 |
Subject: | SGP/EBBR/E19 - Data Missing During Recalibration Changeout |
DataStreams: | sgp15ebbrE19.b1, sgp30baebbrE19.c1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgpebbrE19.00, sgpebbrE19.01 |
Description: | Data was missing during the recalibration changeout. |
Measurements: | sgpebbrE19.01:
sgpebbrE19.00:
sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
sgp30baebbrE19.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1530 | 10/10/2003 | 1600 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/2003 | 1500 | 10/16/2003 | 1530 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1800 | 10/10/2003 | 1800 |
Subject: | SGP/EBBR/E19 - Data All Zeros |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The time period after restart of the datalogger produced all zero data. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1805 | 10/10/2003 | 1805 |
Subject: | SGP/EBBR/E19 - Most Data Incorrect |
DataStreams: | sgp5ebbrE19.b1 |
Description: | Most of the 5 minute data is incorrect after the restart of the datalogger. |
Measurements: | sgp5ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2003 | 1825 | 12/12/2003 | 2000 |
Subject: | SGP/EBBR/E19 - Wind Speed Sensor Frozen Stopped by Ice Storm |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. It is not known how long this condition existed, as data is missing for more than 10 days after the end of the stated period. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/2004 | 1600 | 01/22/2004 | 1530 |
Subject: | SGP/EBBR/E19 - Low Battery Voltage Caused Incorrect Data |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Battery voltage less than 10.5 V caused much data to be questionable or incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2004 | 2120 | 02/02/2004 | 1910 |
Subject: | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1700 | 04/15/2004 | 1530 |
Subject: | SGP/EBBR/E19 - Reprocess: Incorrect Net Rad Calibration Coefficient |
DataStreams: | sgp30baebbrE19.c1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiometer coefficient installed on 2/5/04 for nighttime (negative voltage calibration) was incorrect. Negative net radiations during the subject period can be multiplied by 0.9419 to get corrected net radiation measurements. The sensible (H) and latent heat (LE) fluxes (which are very small at night anyway) can be recalculated using the following equations (where B is Bowen ratio, Rn is corrected net radiation, and G is soil heat flow): LE = -(Rn + G)/(B + 1) H = -(Rn + G + LE) |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
sgp30baebbrE19.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 05/06/2003 | 2359 |
Subject: | SGP/EBBR/E19 - Metadata errors |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The latitude, longitude and altitude of the El Reno (E19) site were incorrectly entered into the ARM database. The correct location of the EBBR.E19 instrument is: Lat: 35.557N Lon: 98.017W Alt: 421m |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/EBBR/E19 - Metadata errors |
DataStreams: | sgp5ebbrE19.b1 |
Description: | The latitude, longitude and altitude of the El Reno (E19) site were incorrectly entered into the ARM database. The correct location of the EBBR.E19 instrument is: Lat: 35.557N Lon: 98.017W Alt: 421m |
Measurements: | sgp5ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/29/2004 | 2215 | 06/10/2004 | 1510 |
Subject: | SGP/EBBR/E19 - AEM Hung Inbetween Home Positions |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The AEM hung inbetween home positions, producing a home signal of zero. Sensible and latent heat fluxes during this period are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/28/2004 | 1430 | 10/28/2004 | 1500 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0655 | 01/07/2005 | 1545 |
Subject: | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1115 | 01/06/2005 | 2055 |
Subject: | SGP/EBBR/E19 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/29/2005 | 0930 | 01/29/2005 | 1300 |
Subject: | SGP/EBBR/E19 - Wind Speed Constant |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Wind Speed was constant at 5 m/s during this period; the reason is unknown. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1700 | 03/05/2005 | 1730 |
Subject: | SGP/EBBR/E19 - Reprocess: Negative Net Rad calibrations |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The calibration for negative net radiation was incorrectly entered in the datalogger program. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2005 | 2300 | 05/12/2005 | 1445 |
Subject: | SGP/EBBR/E19 - Net Radiation Incorrect - Cable Chewed by Rodents |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiation measurement was incorrect after the net radiometer cable was chewed by rodents. Sensible and latent heat fluxes were therefore incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E19 - metadata corrections |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E19 data collected by ARM back to the beginning of the data set in May 1997. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/24/2005 | 0600 | 10/25/2005 | 0100 |
10/31/2005 | 1030 | 12/20/2005 | 1940 |
Subject: | SGP/EBBR/E19 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiometer cable was chewed by an animal. Net Radiation, Sensible Heat Flux, and Latent Heat Flux were incorrect during the stated periods. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2005 | 0000 | 01/19/2006 | 1630 |
Subject: | SGP/EBBR/E19 - Incorrect Sensible and Latent Heat Fluxes |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The gradient measurements and latent and sensible heat fluxes were incorrect because the AEM was not exchanging. The problem was fixed by replacing the AEM. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2008 | 0600 | 05/07/2008 | 0900 |
05/07/2008 | 1530 | 05/07/2008 | 2130 |
05/09/2008 | 1330 | 05/09/2008 | 1330 |
Subject: | SGP/EBBR/E19 - Sensible and latent heat flux and net radiation incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Net radiation was too large, resulting in sensible and latent heat fluxes being too large. The cause of the problem is unknown. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2009 | 1835 | 01/28/2009 | 1825 |
Subject: | SGP/EBBR/E19 - Wind Speed Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Wind Speed was frozen stopped by ice and was incorrect during this period. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/29/2010 | 1130 | 01/31/2010 | 2200 |
Subject: | SGP/EBBR/E19 - Wind direction sensor frozen near north |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The wind direction sensor was frozen in place near north by freezing rain. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/28/2010 | 1630 | 02/02/2010 | 1530 |
Subject: | SGP/EBBR/E19 - Wind speed sensor frozen stopped |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The wind speed sensor was frozen stopped by freezing rain. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/05/2011 | 1030 | 09/19/2011 | 1700 |
Subject: | SGP/EBBR/E19 - Nighttime data missing |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Battery supply voltage was insufficient at night to power the system resulting in missing data. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 1500 | 12/31/1997 | 1520 |
Subject: | SGP/EBBR/E19 - Battery Voltage Drop |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | EBBR battery voltage at E19, El Reno, OK declined to lower than acceptable levels after long periods of clouds after initial installation. The low voltage condition worsened as Autumn progressed. In November 1997 the battery tested okay, but would not hold sufficient capacity at night or during extended periods of clouds to keep the voltage high enough for the EBBR to work properly. At my request, the battery was replaced with a brand new battery on 31 December 1997. The new battery is presently maintaining voltage level at night. The voltage dropped to 10 volts or less many days before the battery change. Voltages less than 10.3 volts affected a wide range of measured values, but at different times. When the voltage was much below 10 volts the home signal became very large (several volts), a quirk of the AEM circuitry. At various times, latent and sensible heat fluxes, soil temperature, air temperature, relative humidity, vapor pressure, wind direction, soil heat flux plate output, home signal, and atmospheric pressure (at least) were not reported correctly by the CR10 datalogger. At least the sensible and latent heat fluxes should be considered to be incorrect when the battery voltage is less than 10.3 volts. The battery voltage is found in the 15 minute data. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 1500 | 07/20/1999 | 1530 |
Subject: | SGP/EBBR/E19 - Noisy Sensible and Latent Heat Fluxes |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | "Noisy" sensible and latent heat fluxes often occur during daytime periods when the net radiation is smaller (less than 150 watts/m2), but this is not the only condition under which it occurs. During this condition especially, the temperature gradient, RH gradient, and thus the vapor pressure gradient are near zero; this causes the sensible and latent heat flux gradients to be inaccurately calculated. Good examples of these conditions occurred on 28 December 1997 and 6 January 1998. However, even when there is substantial net radiation the problem does sometimes occur; good examples of this are found during daytime or nighttime variously on 1, 2, 3, and 4 January 1998. The conditions occur more fequently than at other EBBR sites; they do occur at other EBBR sites, but less frequently. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/04/1998 | 0920 | 01/04/1998 | 1710 |
01/07/1998 | 0745 | 01/09/1998 | 2359 |
Subject: | SGP/EBBR/E19- EBBR Frozen Wind Speed |
DataStreams: | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Wind speed cups were frozen during the indicated time periods. All 5, 15, and 30 minute data values indicated are incorrect for the periods listed. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/1997 | 1528 | 10/09/1997 | 1602 |
Subject: | SGP/EBBR/E19 - 3-Month Check |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for the period indicated. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/1998 | 1430 | 05/07/1998 | 1500 |
Subject: | SGP/EBBR/E19 - Six-Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | During EBBR 6 month checks (formally called 3 month checks) the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed just before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for the period indicated. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/22/1998 | 1105 | 12/23/1998 | 0400 |
Subject: | SGP/EBBR/E19 - Wind Direction Data Incorrect (revised) |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | The wind direction sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: res_ws, wind_d, sigma_wd 15 minute: mv_wind_d 30 minute: res_ws, wind_d, sigma_wd |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/1999 | 2240 | 01/10/1999 | 1530 |
Subject: | SGP/EBBR/E19 - Wind Speed Data Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00, sgp15ebbrE19.b1 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/1998 | 0505 | 12/24/1998 | 1830 |
Subject: | SGP/EBBR/E19 - Wind Speed Data Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/08/1999 | 0500 | 03/11/1999 | 1540 |
Subject: | SGP/EBBR/E19 - Net Radiation Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Water in the net radiometer dome made the net radiation data incorrect. Comparison with surrounding EBBR sites should allow for an approximate correction of the net radiation data. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/1999 | 1430 | 04/16/1999 | 1730 |
Subject: | SGP/EBBR/E19 - Incorrect Tref, Tair Data, Bowen Ratio, latent and sensible heat fluxes |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | All Tref and Tair temperatures, plus bowen ratio, latent heat flux, and sensible heat flux values are incorrect for this period. This problem was caused by mistakenly removing the Tref sensor. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/25/1999 | 1630 | 04/22/1999 | 1500 |
Subject: | SGP/EBBR/E19 - Temperature of Left Humidity Probe Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | A poorly seated lead caused the temperature reading from the left humidity probe to be incorrect. This also affects the calculated vapor pressures,the Bowen ratio, and the sensible and latent heat fluxes. The affected values are: 5 minute: thum_top, thum_bot, vp_top, vp_bot 15 minute: rr_thum_l 30 minute: thum_top, thum_bot, vp_top, vp_bot, bowen, e, h |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|