DQR ID | Subject | Data Streams Affected |
---|---|---|
D080225.1 | TWP/SMET/C3 - Upper Wind Sensor Data Questionable | twpsmet60sC3.b1 |
D080428.2 | TWP/SMET/C1 - Reprocess: ORG Data has very small rainrate values | twpsmet60sC1.b1 |
D080428.3 | TWP/SMET/C3 - Reprocess: ORG Data has very small rainrate values | twpsmet60sC3.b1 |
D080428.4 | TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values | twpsmet60sC2.b1 |
D080611.2 | TWP/SMET/C3 - Lower Wind Direction Intermittently Wrong | twpsmet60sC3.b1 |
D080617.1 | TWP/SMET/C2 - ORG rainfall measurements too large | twpsmet60sC2.b1 |
D080707.2 | TWP/SMET/C1 - ORG Precip Data Incorrect | twpsmet60sC1.b1 |
D080715.1 | TWP/SMET/C3 - Upper wind speed data incorrect | twpsmet60sC3.b1 |
D081022.3 | TWP/SMET/C1 - Wind Speed data contain offset due to induced voltage | twpsmet60sC1.b1 |
D081022.5 | TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage | twpsmet60sC2.b1 |
D081022.8 | TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage | twpsmet60sC3.b1 |
D081027.2 | TWP/SMET/C2 - ORG rainrate high due to calibration. | twpsmet60sC2.b1 |
D090129.4 | TWP/SMET/C3 - Reprocess: Station Pressure values reported in hPa instead of kPa. | twpsmet60sC3.b1 |
D090304.1 | TWP/SMET/C1 - Optical Rain Gage Inoperative | twpsmet60sC1.b1 |
D090515.1 | TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degrees | twpsmet60sC3.b1 |
D090604.2 | TWP/SMET/C2 - Barometer data incorrect | twpsmet60sC2.b1 |
D090708.1 | TWP/SMET/C1 - Reprocess: Barometric pressure data scaled incorrectly | twpsmet60sC1.b1 |
D090918.1 | TWP/SMET/C2 - Induced wind speed when calm | twpsmet60sC2.b1 |
D091023.1 | TWP/SMET/C3 - Tower Lowered for Maintenance | twpsmet60sC3.b1 |
D091030.2 | TWP/SMET/C2 - Tower Lowered for Maintenance | twpsmet60sC2.b1 |
D100303.3 | TWP/SMET/C2 - Barometer failure | twpsmet60sC2.b1 |
D100603.1 | TWP/SMET/C1 - Missing RH, Barometer, and ORG data | twpsmet60sC1.b1 |
D110105.1 | TWP/SMET/C1 - Aux (lower) wind sensor failed | twpsmet60sC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2008 | 0000 | 02/27/2008 | 0315 |
Subject: | TWP/SMET/C3 - Upper Wind Sensor Data Questionable |
DataStreams: | twpsmet60sC3.b1 |
Description: | The wind_up vs. wind_low wind directions diverged, with the differences between the two eventually reached 45 degrees. The Upper sensor was found to be mis-aligned and loose. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/2004 | 0000 | 06/30/2010 | 2359 |
Subject: | TWP/SMET/C1 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | twpsmet60sC1.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We are reprocessing the data to remove these small values and are adjusting the collection program to remove them before ingest. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2004 | 0000 | 06/30/2010 | 2359 |
Subject: | TWP/SMET/C3 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | twpsmet60sC3.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We will reprocess the data to remove these small values. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2004 | 0000 | 06/30/2010 | 2359 |
Subject: | TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | twpsmet60sC2.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We will reprocess the data to remove these small values. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/27/2008 | 1945 | 06/24/2008 | 0113 |
Subject: | TWP/SMET/C3 - Lower Wind Direction Intermittently Wrong |
DataStreams: | twpsmet60sC3.b1 |
Description: | The lower wind sensor cabling had a problem causing an intermittent connection for the wind direction data. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/2008 | 0000 | 08/07/2008 | 2300 |
Subject: | TWP/SMET/C2 - ORG rainfall measurements too large |
DataStreams: | twpsmet60sC2.b1 |
Description: | The ORG was collecting large amounts of rainfall compared to the co-located tipping bucket raingauge. The cable was chewed by mice causing the wires to make contact intermittently mimicking rainfall. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2008 | 1300 | 02/09/2008 | 0600 |
Subject: | TWP/SMET/C1 - ORG Precip Data Incorrect |
DataStreams: | twpsmet60sC1.b1 |
Description: | Moisture intrusion into the sensor body allowed condensation on the lens of the ORG. Continual and long-term precipitation was reported during this time. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/08/2008 | 2045 | 07/17/2008 | 0144 |
Subject: | TWP/SMET/C3 - Upper wind speed data incorrect |
DataStreams: | twpsmet60sC3.b1 |
Description: | Beginning on 07/08, the upper wind sensor started reporting significantly lower wind speeds than the lower wind sensor. The cable connections weather proofing failed allowing corrosion to occur and increasing he resistance of the cables. This in turn lowered the wind speeds artificially. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/1996 | 0000 | 11/03/2008 | 0730 |
Subject: | TWP/SMET/C1 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC1.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/1998 | 0000 | 02/23/2009 | 0410 |
Subject: | TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC2.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0000 | 10/17/2008 | 0627 |
Subject: | TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC3.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/2008 | 2311 | 10/05/2008 | 2344 |
Subject: | TWP/SMET/C2 - ORG rainrate high due to calibration. |
DataStreams: | twpsmet60sC2.b1 |
Description: | The rainrate from the ORG was high due to calibration. This data is not real. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/27/2009 | 1850 | 01/30/2009 | 1535 |
Subject: | TWP/SMET/C3 - Reprocess: Station Pressure values reported in hPa instead of kPa. |
DataStreams: | twpsmet60sC3.b1 |
Description: | An incorrect program was entered into the datalogger. This program did not convert the station pressure from hPa to kPa. This made the values larger by a factor of 10 and caused the QC bit to be tripped. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2009 | 0100 | 04/03/2009 | 0225 |
Subject: | TWP/SMET/C1 - Optical Rain Gage Inoperative |
DataStreams: | twpsmet60sC1.b1 |
Description: | Beginning on 02/07/2009, the trending between the TBRG and ORG began to look poor, one recording precip when the other was not and vice versa. After a while the ORG quit registering any precip at all. ORG was replaced. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/19/2005 | 0420 | 04/04/2009 | 0115 |
Subject: | TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degrees |
DataStreams: | twpsmet60sC3.b1 |
Description: | The temperature of the SMET system was biased low by 1.06 Deg C due to a non-precision resistor being used int he measurement circuit. The data will be reprocessed. Saturation Vapor pressure and Vapor pressure will have to be reprocessed also. Add 1.06 degrees to the temperature data. Correct Sat Vap Press using the Buck approximation: Es = 6.1121exp((17.502*T)/(240.97 + T) where T is the temperature in C. Correct Vapor pressure using: E = (RH*Es)/100 |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2009 | 0004 | 06/05/2009 | 2359 |
Subject: | TWP/SMET/C2 - Barometer data incorrect |
DataStreams: | twpsmet60sC2.b1 |
Description: | Beginning 05/20, atmos_pressure exceeded MAX between ~21:00 and 01:00 UTC on most days. The inlet tube was accidentally pinched in the door of the logger enclosure artificially increasing the atmospheric pressure during the listed times. Only a few hours exceeded max limits. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/06/2009 | 2319 | 07/07/2009 | 1348 |
Subject: | TWP/SMET/C1 - Reprocess: Barometric pressure data scaled incorrectly |
DataStreams: | twpsmet60sC1.b1 |
Description: | The barometer data was scaled incorrectly when a new program was loaded into the datalogger. The pressure data was reported as mb (hPa) instead of the standard kPa. So, in essence the value was a factor of ten to large. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2009 | 0100 | 10/15/2009 | 0300 |
Subject: | TWP/SMET/C2 - Induced wind speed when calm |
DataStreams: | twpsmet60sC2.b1 |
Description: | The upper and lower wind sensors were not trending well at wind speed below 1 m/s. Both sensors were showing values above 0m/s when calm. The lightning protector was at fault resulting in an induced wind voltage during calm conditions. Users should subtract any offset found (for example 0.19 m/s for upper wind speed) when the wind speeds are flat-lined. The offset value was not consistent. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/2009 | 0045 | 09/30/2009 | 0500 |
Subject: | TWP/SMET/C3 - Tower Lowered for Maintenance |
DataStreams: | twpsmet60sC3.b1 |
Description: | The tower was lowered for annual anemometer changes. The wind data is suspect. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/14/2009 | 2150 | 10/15/2009 | 0315 |
Subject: | TWP/SMET/C2 - Tower Lowered for Maintenance |
DataStreams: | twpsmet60sC2.b1 |
Description: | Data is suspect due to the tower being lowered. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/04/2010 | 0600 | 02/23/2010 | 2315 |
Subject: | TWP/SMET/C2 - Barometer failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | The atmos_pressure values were spiking high (up to 110 kPa) from 06:00 UTC on 02/04 until the data went missing at 10:44 UTC on 02/06 when the barometer failed completely. Barometer replaced 2/23. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2010 | 0000 | 05/11/2010 | 0330 |
Subject: | TWP/SMET/C1 - Missing RH, Barometer, and ORG data |
DataStreams: | twpsmet60sC1.b1 |
Description: | Atmos_pressure data suddenly went missing on 03/02 at 07:34 UTC and consequently, the relative humidity data flatlined. Furthermore, after a sudden precipitation event when the max precip rate flag was tripped the TBRG total has not agreed with the comparison ORG or the precip rate plot. A loose wire connection was fixed 3/22 restoring RH and barometer data. A damaged cable was repaired 5/11 restoring ORG data. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/05/2010 | 0000 | 08/29/2010 | 0154 |
Subject: | TWP/SMET/C1 - Aux (lower) wind sensor failed |
DataStreams: | twpsmet60sC1.b1 |
Description: | The lower wind direction sensor on the C1 site was flatlining at 270 degrees throughout most of the daylight hours of the day. During the night the sensor appeared to be working fine. |
Measurements: | twpsmet60sC1.b1:
|