DQR ID | Subject | Data Streams Affected |
---|---|---|
D051031.3 | SGP/ECOR/E14 - CO2/H2O Incorrect | sgp30ecorE14.b1 |
D051216.2 | SGP/ECOR/E14 - Flux Measurements Incorrect | sgp30ecorE14.b1 |
D070223.1 | SGP/ECOR/E14 - Fluxes and Most Measurements Incorrect | sgp30ecorE14.b1 |
D070514.2 | SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing | sgp30ecorE14.b1 |
D080604.2 | SGP/ECOR/E14 - Sensor failure | sgp30ecorE14.b1 |
D120128.3 | SGP/ECOR/E14 - Intermittent missing data | sgp30ecorE14.b1 |
D121001.1 | SGP/ECOR/E14 - Intermittent missing data | sgp30ecorE14.b1 |
D121016.2 | SGP/ECOR/E14 - Missing data | sgp30ecorE14.b1 |
D130913.1 | SGP/ECOR/E14 - CO2 and Latent Heat Fluxes Incorrect | sgp30ecorE14.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/25/2005 | 0000 | 08/29/2005 | 0230 |
Subject: | SGP/ECOR/E14 - CO2/H2O Incorrect |
DataStreams: | sgp30ecorE14.b1 |
Description: | The LI-7500 CO2/H2O sensor stopped working after a rainstorm. CO2 and H2O data are incorrect during the stated period. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/04/2005 | 1330 | 11/17/2005 | 1630 |
12/01/2005 | 1930 | 12/13/2005 | 1630 |
01/24/2006 | 1500 | 02/13/2006 | 1930 |
05/05/2006 | 2100 | 06/13/2006 | 1400 |
07/07/2006 | 1930 | 07/14/2006 | 1500 |
Subject: | SGP/ECOR/E14 - Flux Measurements Incorrect |
DataStreams: | sgp30ecorE14.b1 |
Description: | The ECOR datastream was corrupted; this happens when the ECOR program produces a datastream of the wrong length (i.e., leaves one or more measurements out). Fluxes and some other measurements are incorrect. Reprocessing will not correct this problem; the raw data are corrupted. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/14/2007 | 0500 | 02/02/2007 | 1600 |
Subject: | SGP/ECOR/E14 - Fluxes and Most Measurements Incorrect |
DataStreams: | sgp30ecorE14.b1 |
Description: | The ECOR system was having major problems during this period and most measurements were incorrect most of the time. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/09/2007 | 1300 | 05/19/2007 | 1700 |
Subject: | SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing |
DataStreams: | sgp30ecorE14.b1 |
Description: | The temp_irga was too large 05/09/07 1300 GMT - 05/10/07 2000 GMT. The temp_irga was flat lined at 49.96 C 05/10/07 2030 GMT - 05/17/07 2000 GMT. The temp_irga was missing 05/17/07 2030 GMT - 05/19/07 1700 GMT. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/02/2008 | 1330 | 06/05/2008 | 1930 |
Subject: | SGP/ECOR/E14 - Sensor failure |
DataStreams: | sgp30ecorE14.b1 |
Description: | The water vapor output of the LI-7500 was too low, indicating that water vapor leaked into the sensor and that the chemicals are spent or there was an electronic failure. Latent heat flux was not normally affected by this problem. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/04/2011 | 1330 | 11/29/2011 | 2100 |
Subject: | SGP/ECOR/E14 - Intermittent missing data |
DataStreams: | sgp30ecorE14.b1 |
Description: | Many times during a month there was missing data because of a failing UPS. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/04/2012 | 2100 | 09/19/2012 | 2000 |
Subject: | SGP/ECOR/E14 - Intermittent missing data |
DataStreams: | sgp30ecorE14.b1 |
Description: | The ecor computer at E14 locked up. Cooling fans were replaced, and the computer was returned to service and collecting data. Some data loss has occurred after the computer was virtualized, but data loss has not occurred recently. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/2012 | 1930 | 10/09/2012 | 1800 |
Subject: | SGP/ECOR/E14 - Missing data |
DataStreams: | sgp30ecorE14.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/08/2013 | 2200 | 09/13/2013 | 1430 |
Subject: | SGP/ECOR/E14 - CO2 and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ecorE14.b1 |
Description: | Various data values from the CO2/H2O instrument were missing at different times. |
Measurements: | sgp30ecorE14.b1:
|