Data Quality Reports for Session: 178560 User: tjphillips Completed: 07/22/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D021113.2SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30baebbrE20.c1
D040507.2SGP/EBBR/E20 - Left Air Temperature Incorrectsgp30baebbrE20.c1
D050114.7SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9 - BA EBBR VAP Bulk Aerodynamicssgp30baebbrE20.c1


DQRID : D021113.2
Start DateStart TimeEnd DateEnd Time
10/01/1995000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30baebbrE20.c1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30baebbrE20.c1:
  • cs4
  • cs5
  • cs2
  • cs3
  • cs1


Back To Table of Contents

DQRID : D040507.2
Start DateStart TimeEnd DateEnd Time
03/01/2004000003/31/20042355
Subject:
SGP/EBBR/E20 - Left Air Temperature Incorrect
DataStreams:sgp30baebbrE20.c1
Description:
The left air temperature, and therefore top and bottom air temperatures
were offscale or incorrect on occasion.  Bowen ratio, sensible heat flux, and latent heat 
flux were also incorrect during those times.

Inspection of the data is required to detect the incorrect periods.
Measurements:sgp30baebbrE20.c1:
  • Corrected sensible heat flux(h)
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, best estimate(hcomb)
  • tair_top
  • bowen
  • Heat flux, latent(e)
  • tair_bot
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, sensible, aerodynamic(ah)


Back To Table of Contents

DQRID : D050114.7
Start DateStart TimeEnd DateEnd Time
10/01/1995000006/30/20032330
Subject:
SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9  - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE20.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the calculation of bulk 
aerodynamic sensible and latent heat fluxes instead of site specific heights.

This resulted in either under-estimation or over-estimation of the sensible and latent 
heat fluxes.
Measurements:sgp30baebbrE20.c1:
  • austar
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, best estimate(hcomb)
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, sensible, aerodynamic(ah)


Back To Table of Contents



END OF DATA