DQR ID | Subject | Data Streams Affected |
---|---|---|
D021113.2 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30baebbrE20.c1 |
D040507.2 | SGP/EBBR/E20 - Left Air Temperature Incorrect | sgp30baebbrE20.c1 |
D050114.7 | SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9 - BA EBBR VAP Bulk Aerodynamics | sgp30baebbrE20.c1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/1995 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30baebbrE20.c1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30baebbrE20.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2004 | 0000 | 03/31/2004 | 2355 |
Subject: | SGP/EBBR/E20 - Left Air Temperature Incorrect |
DataStreams: | sgp30baebbrE20.c1 |
Description: | The left air temperature, and therefore top and bottom air temperatures were offscale or incorrect on occasion. Bowen ratio, sensible heat flux, and latent heat flux were also incorrect during those times. Inspection of the data is required to detect the incorrect periods. |
Measurements: | sgp30baebbrE20.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/1995 | 0000 | 06/30/2003 | 2330 |
Subject: | SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9 - BA EBBR VAP Bulk Aerodynamics |
DataStreams: | sgp30baebbrE20.c1 |
Description: | Fixed AEM and wind speed sensor heights were improperly used in the calculation of bulk aerodynamic sensible and latent heat fluxes instead of site specific heights. This resulted in either under-estimation or over-estimation of the sensible and latent heat fluxes. |
Measurements: | sgp30baebbrE20.c1:
|