Data Quality Reports for Session: 178584 User: draperc1 Completed: 07/24/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D000221.5SGP/EBBR - EBBR E15 Anemometer Cup Off, Wind Speed Incorrectsgp30ebbrE15.b1
D000221.8SGP/EBBR - EBBR E12 Anemometer Cups Frozen, Wind Speed Incorrectsgp30ebbrE12.b1
D000225.10SGP/EBBR - EBBR E12 Net Radiation Incorrectsgp30ebbrE12.b1
D000225.2SGP/EBBR- EBBR E15 Air Temperatures Incorrectsgp30ebbrE15.b1
D000225.7SGP/EBBR - EBBR E13 Left Aspirator Not Workingsgp30ebbrE13.b1
D000301.1SGP/EBBR - EBBR E12 Net Radiation Incorrectsgp30ebbrE12.b1
D000301.3SGP/EBBR - EBBR E13 Net Radiation Incorrectsgp30ebbrE13.b1
D000531.4SGP/EBBR/E13 - failure of sensorssgp30ebbrE13.b1
D000531.5SGP/EBBR/E13 - Failed Right Humidity Probesgp30ebbrE13.b1
D000628.1SGP/EBBR/E13- Left humidity probe replacedsgp30ebbrE13.b1
D010213.1SGP/EBBR/E12 - EBBR E12 Wind Speed Icedsgp30ebbrE12.b1
D010213.2SGP/EBBR/E12 - EBBR E12 Wind Speed Icedsgp30ebbrE12.b1
D010213.3SGP/EBBR/E15 - EBBR E15 Wind Speed Icedsgp30ebbrE15.b1
D010402.13SGP/EBBR/E12 - E12 EBBR Wind Direction Incorrectsgp30ebbrE12.b1
D010402.14SGP/EBBR/E12 - E12 EBBR Wind Speed Incorrectsgp30ebbrE12.b1
D010402.16SGP/EBBR/E12 - E12 EBBR AEM Stuck - Data Incorrectsgp30ebbrE12.b1
D010403.10SGP/EBBR/E13 - E13 EBBR Flux Data Incorrectsgp30ebbrE13.b1
D010403.16SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.17SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.18SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.19SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.2SGP/EBBR/E13 - E13 EBBR Heat Capacities Incorrectsgp30ebbrE13.b1
D010403.20SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.22SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.24SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.3SGP/EBBR/E13 - E13 EBBR Flux Data Incorrectsgp30ebbrE13.b1
D010403.35SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.36SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.37SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.38SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.39SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.4SGP/EBBR/E13 - E13 EBBR Flux Data Incorrectsgp30ebbrE13.b1
D010403.40SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.41SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.42SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.43SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.44SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.45SGP/EBBR/E13 - E13 EBBR All Data Incorrectsgp30ebbrE13.b1
D010403.6SGP/EBBR/E13 - E13 EBBR Flux Data Incorrectsgp30ebbrE13.b1
D010403.8SGP/EBBR/E13 - E13 EBBR Flux Data Incorrectsgp30ebbrE13.b1
D010403.9SGP/EBBR/E13 - E13 EBBR Flux Data Incorrectsgp30ebbrE13.b1
D010412.1SGP/EBBR/E13 - E13 EBBR Soil Temperature #4 Suspectsgp30ebbrE13.b1
D010413.1SGP/EBBR/E13 - E13 EBBR Wind Direction Icedsgp30ebbrE13.b1
D010413.2SGP/EBBR/E13 - E13 EBBR Soil Heat Flow #4 Incorrectsgp30ebbrE13.b1
D010413.3SGP/EBBR/E15 - E15 EBBR Reference Temperature Incorrectsgp30ebbrE15.b1
D010413.4SGP/EBBR/E15 - E15 EBBR Data Incorrectsgp30ebbrE15.b1
D010413.5SGP/EBBR/E15 - E15 EBBR Data Missingsgp30ebbrE15.b1
D010413.6SGP/EBBR/E15 - E15 EBBR Data Incorrectsgp30ebbrE15.b1
D010413.7SGP/EBBR/E15 - E15 EBBR Data Missingsgp30ebbrE15.b1
D010413.8SGP/EBBR/E15 - E15 EBBR Some Soil Temperatures and Heat Flows Incorrectsgp30ebbrE15.b1
D010413.9SGP/EBBR/E15 - E15 EBBR Some Soils and Flux Data Incorrectsgp30ebbrE15.b1
D010416.1SGP/EBBR/E15 - E15 EBBR AEM Stuck in Middlesgp30ebbrE15.b1
D010416.2SGP/EBBR/E15 - E15 EBBR AEM Replacementsgp30ebbrE15.b1
D010416.3SGP/EBBR/E15 - E15 EBBR Battery Voltage Lowsgp30ebbrE15.b1
D010416.4SGP/EBBR/E15 - E15 EBBR Incorrect Net Radiationsgp30ebbrE15.b1
D010605.5SGP EBBR E13 - E13 EBBR Soil T #4 Incorrectsgp30ebbrE13.b1
D011127.26SGP EBBR E12 - E12 EBBR Data Incorrect During 6 Month Checkssgp30ebbrE12.b1
D011127.27SGP EBBR E13 - E13 EBBR Data Incorrect During 6 Month Checkssgp30ebbrE13.b1
D011127.28SGP EBBR E15 - E15 EBBR Data Incorrect During 6 Month Checkssgp30ebbrE15.b1
D011207.11SGP EBBR E12 - E12 EBBR Data Incorrect From AEM In One Positionsgp30ebbrE12.b1
D011207.12SGP EBBR E15 - E15 EBBR Battery Voltage Low, Data Incorrectsgp30ebbrE15.b1
D011218.1SGP EBBR E15 - E15 EBBR Data Zeros Incorrectsgp30ebbrE15.b1
D020129.1SGP EBBR E15 - E15 EBBR Recalibration Changeoutsgp30ebbrE15.b1
D020129.10SGP/EBBR/E13 - Reprocess: E13 EBBR Soil heat Flows #1 and #2 Incorrectsgp30ebbrE13.b1
D020129.11SGP EBBR E13 - E13 EBBR Data Incorrectsgp30ebbrE13.b1
D020129.12SGP EBBR E13 - E13 EBBR Left T/RH Probe Temperature Incorrectsgp30ebbrE13.b1
D020129.13SGP EBBR E13 - E13 EBBR Left T/RH Probe Temperature Incorrectsgp30ebbrE13.b1
D020129.2SGP EBBR E13 - E13 EBBR AEM in Mid Positionsgp30ebbrE13.b1
D020129.3SGP EBBR E13 - E13 EBBR AEM Home 30 Offsetsgp30ebbrE13.b1
D020129.4SGP EBBR E13 - E13 EBBR AEM Home 30 Offset or AEM in Mid Positionsgp30ebbrE13.b1
D020129.5SGP EBBR E13 - E13 EBBR Left Air Temperature Incorrectsgp30ebbrE13.b1
D020129.7SGP EBBR E13 - E13 EBBR Left Air Temperature Incorrectsgp30ebbrE13.b1
D020129.8SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrectsgp30ebbrE13.b1
D020129.9SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrectsgp30ebbrE13.b1
D020131.13SGP/EBBR/E13 - Left T/RH Probe Temperature Incorrectsgp30ebbrE13.b1
D020214.1SGP/EBBR/E13 - Left Humidity Probe Temperature Incorrectsgp30ebbrE13.b1
D020214.2SGP/EBBR/E13 - Data incorrect during maintenancesgp30ebbrE13.b1
D020214.5SGP/EBBR/E13 - Data Incorrect During 6 Month Checkssgp30ebbrE13.b1
D020214.7SGP/EBBR/E15 - Data Incorrect During 6 Month Checkssgp30ebbrE15.b1
D020628.1SGP/EBBR/E12 - 3-month Checksgp30ebbrE12.b1
D020628.15SGP/EBBR/E12 - T/RH Checksgp30ebbrE12.b1
D020628.16SGP/EBBR/E13 - T/RH Checksgp30ebbrE13.b1
D020628.17SGP/EBBR/E15 - T/RH Checksgp30ebbrE15.b1
D020628.2SGP/EBBR/E13 - 3-month Checksgp30ebbrE13.b1
D020628.3SGP/EBBR/E15 - 3-month Checksgp30ebbrE15.b1
D020716.11SGP/EBBR/E12 - 6 Month Checkssgp30ebbrE12.b1
D020716.12SGP/EBBR/E13 - 6 Month Checkssgp30ebbrE13.b1
D020716.13SGP/EBBR/E15 - 6 Month Checkssgp30ebbrE15.b1
D020717.10SGP/EBBR/E12 - AEM Hungsgp30ebbrE12.b1
D020717.11SGP/EBBR/E12 - Measurements Incorrectsgp30ebbrE12.b1
D020717.12SGP/EBBR/E12 - Resistance Measurements Incorrectsgp30ebbrE12.b1
D020717.13SGP/EBBR/E13 - Reprocess: Soil Heat Flow #1 Incorrectsgp30ebbrE13.b1
D020717.14SGP/EBBR/E13 - Reprocess: Soil Heat Flow #2 Incorrectsgp30ebbrE13.b1
D020717.15SGP/EBBR/E13 - Wrong CR10 Program Installedsgp30ebbrE13.b1
D020717.16SGP/EBBR/E13 - Wind Direction Incorrectsgp30ebbrE13.b1
D020717.17SGP/EBBR/E13 - AEM Hung upsgp30ebbrE13.b1
D020717.6SGP/EBBR/E12 - Reprocess: Soil Temperature #3 Incorrectsgp30ebbrE12.b1
D020717.7SGP/EBBR/E12 - Wind Direction Incorrectsgp30ebbrE12.b1
D020717.8SGP/EBBR/E12 - Reprocess: Soil Moisture 4 and 5 Incorrectsgp30ebbrE12.b1
D020717.9SGP/EBBR/E12 - Reprocess: Soil Moisture 2 and 5 Incorrectsgp30ebbrE12.b1
D020723.1SGP/EBBR/E13 - Thermocouple out of range, data incorrectsgp30ebbrE13.b1
D020726.2SGP/EBBR/E13 - Reprocess: Soil Heat Flow #1 and #2 Incorrectsgp30ebbrE13.b1
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE15.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1
D021113.2SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30baebbrE13.c1, sgp30baebbrE15.c1
D021113.3SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30baebbrE12.c1
D021113.4SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE12.b1
D030110.33SGP/EBBR/E12 - Data Incorrect during 6 month checkssgp30ebbrE12.b1
D030110.34SGP/EBBR/E13 - Data Incorrect during 6 month checkssgp30ebbrE13.b1
D030110.35SGP/EBBR/E15 - Data Incorrect during 6 month checkssgp30ebbrE15.b1
D030114.11SGP/EBBR/E12 - Resistance-based Measurements Incorrectsgp30ebbrE12.b1
D030114.12SGP/EBBR/E12 - Wind Direction Incorrectsgp30ebbrE12.b1
D030114.13SGP/EBBR/E12 - Data zero following Logger Restartsgp30ebbrE12.b1
D030114.14SGP/EBBR/E12 - Battery Voltage Lowsgp30ebbrE12.b1
D030114.19SGP/EBBR/E12 - AEM Stuck in One Positionsgp30ebbrE12.b1
D030115.2SGP/EBBR/E12 - Reprocess: Net Rad Calibration Coefficientssgp30ebbrE12.b1
D030115.3SGP/EBBR/E12 - Data Mostly Zero Following Logger Restartsgp30ebbrE12.b1
D030115.4SGP/EBBR/E13 - Wind Speed Stalling at Low Speedssgp30ebbrE13.b1
D030115.5SGP/EBBR/E13 - Reprocess: Soil Moisture #1 Offset1sgp30ebbrE13.b1
D030115.6SGP/EBBR/E13 - AEM Jung between Home Positionssgp30ebbrE13.b1
D030115.7SGP/EBBR/E15 - Reprocess: Soil Moisture #1 Offsetsgp30ebbrE15.b1
D030115.8SGP/EBBR/E15 - Data Mostly Zero Following Logger Restartsgp30ebbrE15.b1
D030115.9SGP/EBBR/E15 - Pressure Lowsgp30ebbrE15.b1
D030711.21SGP/EBBR/E12 - AEM Hung Inbetween Home Positionssgp30ebbrE12.b1
D030712.16SGP/EBBR/E12 - 6 Month Checkssgp30ebbrE12.b1
D030712.17SGP/EBBR/E13 - 6 Month Checkssgp30ebbrE13.b1
D030712.18SGP/EBBR/E15 - 6 Month Checkssgp30ebbrE15.b1
D030724.2SGP/EBBR/E15 - Wind Direction 10 Degrees Lowsgp30ebbrE15.b1
D030728.2SGP/EBBR/E15 - Top Humidity reported as zero in 30 minute data.sgp30ebbrE15.b1
D030919.8SGP/EBBR/E13 - Water In Net Radiometer; Surface Fluxes are Incorrectsgp30ebbrE13.b1
D031031.2SGP/EBBR/E15 - Reference Temperature Failedsgp30ebbrE15.b1
D031031.4SGP/EBBR/E12 - Water in Net Radiometer, Surface Fluxes Incorrectsgp30ebbrE12.b1
D031031.5SGP/EBBR/E13 - Water in Net Radiometer, Surface Fluxes Incorrectsgp30ebbrE13.b1
D031031.6SGP/EBBR/E15 - Water In Net Radiometer, Surface Fluxes Incorrectsgp30ebbrE15.b1
D031031.9SGP/EBBR/E15 - Soil Temperature #5 Incorrect, Surface Fluxes Incorrectsgp30ebbrE15.b1
D031106.1SGP/EBBR/E15 - Soil Temperature #5 Incorrect, Surface Fluxes Incorrectsgp30ebbrE15.b1
D031110.7SGP/EBBR/E15 - AEM Hung Between Home Positions, Surface Fluxes Incorrectsgp30ebbrE15.b1
D031124.12SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltagesgp30ebbrE12.b1
D031204.10SGP/EBBR/E13 - 6 Month Checkssgp30ebbrE13.b1
D031204.11SGP/EBBR/E15 - 6 Month Checkssgp30ebbrE15.b1
D031204.9SGP/EBBR/E12 - 6 Month Checkssgp30ebbrE12.b1
D031217.4SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltagesgp30ebbrE12.b1
D031222.15SGP/EBBR/E12 - Wind Speed Sensor Frozen By Ice Stormsgp30ebbrE12.b1
D031222.16SGP/EBBR/E13 - Wind Speed Sensor Frozen By Ice Stormsgp30ebbrE13.b1
D031222.17SGP/EBBR/E13 - Net Radiometer Iced Over During Stormsgp30ebbrE13.b1
D031222.18SGP/EBBR/E15 - Net Radiometer Iced Over During Stormsgp30ebbrE15.b1
D031222.19SGP/EBBR/E15 - Wind Speed Sensor Frozen By Ice Stormsgp30ebbrE15.b1
D040112.1SGP/EBBR/E15 - Wind Direction About 130 Degrees Lowsgp30ebbrE15.b1
D040227.1SGP/EBBR/E15 - Net Radiometer not levelsgp30ebbrE15.b1
D040304.10SGP/EBBR/E12 - Wind Speed Frozen Stopped By Icesgp30ebbrE12.b1
D040304.11SGP/EBBR/E12 - Wind Direction Frozen Stopped By Icesgp30ebbrE12.b1
D040304.12SGP/EBBR/E13 - Wind Speed Frozen Stopped By Icesgp30ebbrE13.b1
D040304.13SGP/EBBR/E13 - Wind Direction Frozen Stopped By Icesgp30ebbrE13.b1
D040304.14SGP/EBBR/E15 - Wind Speed Frozen Stopped By Icesgp30ebbrE15.b1
D040507.1SGP/EBBR/E15 - Wind Speed Incorrectsgp30baebbrE15.c1, sgp30ebbrE15.b1
D040608.6SGP/EBBR/E13 - Automatic Exchange Mechanism Failuresgp30ebbrE13.b1
D040615.3SGP/EBBR/E12 - Incorrect Timessgp30ebbrE12.b1, sgp30baebbrE12.c1
D040615.6SGP/SWATS/E12 - Time driftsgpswatsE12.b1
D040915.2SGP/EBBR/E13 - Net Radiation Incorrect, Fluxes Incorrectsgp30ebbrE13.b1
D040915.6SGP/EBBR/E13 - AEM Failure, Fluxes Incorrectsgp30ebbrE13.b1
D041004.4SGP/EBBR/E15 - Soil Moisture Coefficients Incorrectsgp30ebbrE15.b1
D041222.11SGP/EBBR/E12 - 6 Month Checkssgp30ebbrE12.b1
D041222.12SGP/EBBR/E13 - 6 Month Checkssgp30ebbrE13.b1
D041222.13SGP/EBBR/E15 - 6 Month Checkssgp30ebbrE15.b1
D041222.2SGP/EBBR/E12 - AEM home_15 Incorrect, Flux Measurements not affectedsgp30ebbrE12.b1
D050114.7SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9 - BA EBBR VAP Bulk Aerodynamicssgp30baebbrE13.c1, sgp30baebbrE15.c1
D050117.8SGP/EBBR/E12 - BA EBBR VAP Bulk Aerodynamicssgp30baebbrE12.c1
D050206.10SGP/EBBR/E13 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE13.b1
D050206.11SGP/EBBR/E15 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE15.b1
D050206.9SGP/EBBR/E12 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE12.b1
D050207.5SGP/EBBR/E12 - Wind Direction Frozen Stopped By Ice Stormsgp30ebbrE12.b1
D050207.6SGP/EBBR/E13 - Wind Direction Frozen Stopped By Ice Stormsgp30ebbrE13.b1
D050207.7SGP/EBBR/E15 - Wind Direction Frozen Stopped By Ice Stormsgp30ebbrE15.b1
D050215.16SGP/EBBR/E12 - Wind Speed Frozen Stopped By Icesgp30ebbrE12.b1
D050215.17SGP/EBBR/E12 - Wind Direction Frozen Stopped By Icesgp30ebbrE12.b1
D050215.18SGP/EBBR/E15 - Wind Speed Frozen Stopped By Icesgp30ebbrE15.b1
D050215.19SGP/EBBR/E15 - Wind Direction Frozen Stopped By Icesgp30ebbrE15.b1
D050304.1SGP/EBBR/E12 - Wind Speed and Direction Frozen by Ice Stormsgp30ebbrE12.b1
D050324.1SGP/EBBR/E15 - Soil Heat Flows Undermeasured, and Latent and Sensible Heat Fluxes
Overstimated
sgp30ebbrE15.b1
D050503.6SGP/SWATS/E12 - Reprocessing Notice (RID 156)sgpswatsE12.b1
D050503.8SGP/SWATS/E13 - Reprocessing Notice (RID 156)sgpswatsE13.b1
D050510.3SGP/EBBR/E13 - Net Radiometer Tilted Half Degree Westsgp30ebbrE13.b1
D050622.1SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect (AEM failure)sgp30ebbrE13.b1
D050624.2SGP/EBBR/E15 - Net Radiation Too Large - Water in Bottomsgp30ebbrE15.b1
D050624.7SGP/EBBR/E13 - Improved EBBR CR10 Programsgp30ebbrE13.b1
D050719.10SGP/EBBR/E15 - Improved EBBR CR10 Programsgp30ebbrE15.b1
D050719.9SGP/EBBR/E12 - Improved EBBR CR10 Programsgp30ebbrE12.b1
D051104.2SGP/EBBR/E13 - Fluxes Incorrectsgp30ebbrE13.b1
D051104.3SGP/EBBR/E13 - Loose connectionssgp30ebbrE13.b1
D051106.23SGP/EBBR/E12 - Average Soil Heat Flux Incorrectsgp30ebbrE12.b1
D051106.24SGP/EBBR/E13 - Average Soil Heat Flux Incorrectsgp30ebbrE13.b1
D051106.25SGP/EBBR/E15 - Average Soil Heat Flux Incorrectsgp30ebbrE15.b1
D051106.9SGP/EBBR/E15 - Soil Set #5 Temperature, Moisture, and Heat Flow Incorrectsgp30ebbrE15.b1
D051111.10SGP/EBBR/E12 - metadata correctionssgp30ebbrE12.b1
D051111.11SGP/EBBR/E13 - metadata correctionssgp30ebbrE13.b1
D051111.12SGP/EBBR/E15 - metadata correctionssgp30ebbrE15.b1
D051215.3SGP/EBBR/E15 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect.sgp30ebbrE15.b1
D060111.10SGP/EBBR/E15 - Incorrect Sensible and Latent Heat Fluxessgp30ebbrE15.b1
D060111.11SGP/EBBR/E15 - Reprocess: Sensible and Latent Heat Fluxes, Soil Set #2 Sometimes Incorrectsgp30ebbrE15.b1
D060111.5SGP/EBBR/E12 - Sensible and Latent Heat Fluxes Incorrect at Timessgp30ebbrE12.b1
D060111.8SGP/EBBR/E12 - Multiplexer failuresgp30ebbrE12.b1
D060111.9SGP/EBBR/E13 - Wind Speed Sensor Frozensgp30ebbrE13.b1
D060501.11SGP/EBBR/E12 - Fluxes and Gradient Measurements Incorrectsgp30ebbrE12.b1
D060501.12SGP/EBBR/E13 - Missing Datasgp30ebbrE13.b1
D060501.13SGP/EBBR/E13 - Flux and Gradient Measurements Incorrectsgp30ebbrE13.b1
D060501.14SGP/EBBR/E13 - Net Radiation and Fluxes Suspectsgp30ebbrE13.b1
D060501.15SGP/EBBR/E15 - Wind Speed Sensor Frozen Stoppedsgp30ebbrE15.b1
D060622.1SGP/EBBR/E13 - Left Air Temperature Incorrect - Fluxes Affectedsgp30ebbrE13.b1
D060622.2SGP/EBBR/E13 - Fluxes Incorrect, AEM Problemssgp30ebbrE13.b1
D060802.1SGP/SWATS/E12 - Incorrect soil moisturesgpswatsE12.b1
D060818.10SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect When Pressure Offscalesgp30ebbrE13.b1
D060921.3SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE12.b1
D060921.4SGP/EBBR/E12 - Soil Temperature #1 Incorrectsgp30ebbrE12.b1
D060921.5SGP/EBBR/E13 - Soil Heat Flow #3 Large Negativesgp30ebbrE13.b1
D060921.6SGP/EBBR/E13 - Pressure and Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE13.b1
D060921.7SGP/EBBR/E13 - Most Measurements Incorrect When Battery Voltage Too lowsgp30ebbrE13.b1
D061114.6SGP/EBBR/E13 - Battery failuresgp30ebbrE13.b1
D070917.1SGP/EBBR/E13 - Radiometer dome brokensgp30ebbrE13.b1
D071026.2SGP/SWATS/E12 - Reprocess: Incorrect calibrationssgpswatsE12.b1
D080318.1SGP/EBBR/E13 - Wind direction failuresgp30ebbrE13.b1
D080616.4SGP/EBBR/E15 - Water in domesgp30ebbrE15.b1
D080616.5SGP/EBBR/E15 - Soil Heat Flow #4 Incorrectsgp30ebbrE15.b1
D081210.12SGP/SWATS/E15 - Sensor failure, 5cm EsgpswatsE15.b1
D081210.13SGP/SWATS/E15 - Incorrect soil moisturesgpswatsE15.b1
D090313.12SGP/EBBR/E12 - Wind Speed Incorrectsgp30ebbrE12.b1
D090313.13SGP/EBBR/E13 - Wind Speed Incorrectsgp30ebbrE13.b1
D090313.14SGP/EBBR/E15 - Wind Speed Incorrectsgp30ebbrE15.b1
D090313.2SGP/EBBR/E15 - Soil Moisture and Soil Temp #1 Incorrectsgp30ebbrE15.b1
D100223.1SGP/EBBR/E12 - Wind Speed Sensor Frozen Stopped by Icingsgp30ebbrE12.b1
D100510.1SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Low (Net Radiation too low)sgp30ebbrE15.b1
D100720.2SGP/EBBR/E12 - Intermittent data losssgp30ebbrE12.b1
D100720.3SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Other Measurements Incorrectsgp30ebbrE12.b1
D100727.5SGP/EBBR/E13 - Incorrect Sensible and Latent Heat Fluxessgp30ebbrE13.b1
D101004.1SGP/EBBR/E12 - Net radiation too highsgp30ebbrE12.b1
D101004.2SGP/EBBR/E13 - Net Radiation Too Largesgp30ebbrE13.b1
D101007.1SGP/EBBR/E15 - Sensible and Latent Heat Flux Suspect - Soil Heat Flow 5 Problemsgp30ebbrE15.b1
D110629.1SGP/SWATS/E13 - Lightning damagesgpswatsE13.b1
D110707.1SGP/SWATS/E15 - Missing datasgpswatsE15.b1
D110721.1SGP/EBBR/E13 - Soil temperature #3 offscalesgp30ebbrE13.b1
D110830.1SGP/EBBR/E12 - Loose connection (SHF #4)sgp30ebbrE12.b1
D120128.2SGP/EBBR/E15 - Soil heat flow #1 failuresgp30ebbrE15.b1
D120305.1SGP/EBBR/E15 - Soil heat flow #5 failuresgp30ebbrE15.b1
D120307.1SGP/EBBR/E12 - Soil heat flux #4 intermittently incorrectsgp30ebbrE12.b1
D120507.4SGP/EBBR/E15 - Sensible and Latent heat fluxes incorrectsgp30ebbrE15.b1
D120507.5SGP/EBBR/E12 - Sensible and Latent heat fluxes incorrectsgp30ebbrE12.b1
D121107.1SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE15.b1
D130110.4SGP/EBBR/E15 - Sensible and latent heat fluxes incorrectsgp30ebbrE15.b1
D130110.5SGP/EBBR/E12 - Sensible and latent heat fluxes intermittently incorrectsgp30ebbrE12.b1
D130201.4SGP/EBBR/E12 - Net rad too highsgp30ebbrE12.b1
D130410.10SGP/EBBR/E15 - AEM failuresgp30ebbrE15.b1
D130410.4SGP/EBBR/E12 - AEM failuresgp30ebbrE12.b1
D130410.5SGP/EBBR/E13 - Soil temp 5 offscalesgp30ebbrE13.b1
D130410.6SGP/EBBR/E13 - Soil temp 4 failuresgp30ebbrE13.b1
D130410.7SGP/EBBR/E13 - AEM failuresgp30ebbrE13.b1
D130410.9SGP/EBBR/E15 - Missing datasgp30ebbrE15.b1
D130507.2SGP/EBBR/E12 - Soil temp 1 erraticsgp30ebbrE12.b1
D130621.1SGP/EBBR/E13 - Incorrect sensible and latent heat fluxessgp30ebbrE13.b1
D130718.3SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE15.b1
D130930.1SGP/SWATS/E15 - Noisy East 25cm sensor datasgpswatsE15.b1
D131114.3SGP/EBBR/E15 - Soil temp 3 failuresgp30ebbrE15.b1
D131216.3SGP/EBBR/E12 - Multiplexer/datalogger problemssgp30ebbrE12.b1
D140117.7SGP/EBBR/E12 - Intermittent spikes in soil temp 1sgp30ebbrE12.b1
D140318.5SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Too Large, Net Radiation Too Largesgp30ebbrE13.b1
D150309.5SGP/EBBR/E13 - Reprocess: Incorrect data logger programsgp30ebbrE13.b1
D930428.2SGP/EBBR/E13 - incorrect home signalsgp30ebbrE13.b1
D930503.2SGP/EBBR/E13 - incorrect meteorological observationssgp30ebbrE13.b1
D931108.3SGP/EBBR/E13 - pressure calibrationsgp30ebbrE13.b1
D931108.4SGP/EBBR/E13 - solid moisture correctionsgp30ebbrE13.b1
D940105.1Incorrect readings for pressure sensorsgp30ebbrE15.b1
D940105.4SGP/EBBR/E15 - Questionable data due to low voltage at E15sgp30ebbrE15.b1
D940106.2SGP/EBBR/E12 - Invalid data due to blown AEM fuse at E12sgp30ebbrE12.b1
D940106.5SGP/EBBR/E13 - Invalid data during disconnection of AEM at E13sgp30ebbrE13.b1
D940511.2SGP/EBBR/E13 - SM4 Replacementsgp30ebbrE13.b1
D940616.3SGP/EBBR/E12 - Wind Directionsgp30ebbrE12.b1
D940711.3SGP/EBBR/E12 - Aspirator Failuresgp30ebbrE12.b1
D940808.2SGP/EBBR/E12 - Stopped Ventilation Fansgp30ebbrE12.b1
D940909.1SGP/EBBR/E12 - Miscellaneous Problems Affecting Datasgp30ebbrE12.b1
D941021.12SGP/EBBR/E12 - Net Radiometer Hemisphere Changessgp30ebbrE12.b1
D941021.13SGP/EBBR/E15 - Net Radiometer Hemisphere Changessgp30ebbrE15.b1
D941021.5SGP/EBBR/E13 - Soil Temperature Aberationssgp30ebbrE13.b1
D941021.6SGP/EBBR/E12 - Low home_15 Valuessgp30ebbrE12.b1
D941021.8SGP/EBBR/E15 - Net Radiometer Hemisphere Changessgp30ebbrE15.b1
D941208.1SGP/EBBR/E13 - Net Radiation - Hemisphere Replacementsgp30ebbrE13.b1
D950126.1SGP/EBBR/E13 - Incorrect Soil Temperature #4sgp30ebbrE13.b1
D950126.4SGP/EBBR/E15 - Frozen Wind Speed Instrumentsgp30ebbrE15.b1
D950626.1SGP/EBBR/E13 - Frozen Wind Speed Sensorsgp30ebbrE13.b1
D950626.15SGP/EBBR/E12 - Wind Direction Malfunctionsgp30ebbrE12.b1
D950626.16SGP/EBBR/E12 - Wind Direction Malfunctionsgp30ebbrE12.b1
D950626.2SGP/EBBR/E13 - Frozen Wind Speed Sensorsgp30ebbrE13.b1
D950626.20SGP/EBBR/E15 - Battery Voltage Drop, Storage Module Changesgp30ebbrE15.b1
D950626.3SGP/EBBR/E15 - Frozen Wind Speed Sensorsgp30ebbrE15.b1
D950626.7SGP/EBBR/E13 - Reprocess: Soil Temperature Malfunctionsgp30ebbrE13.b1
D950719.2SGP/EBBR/E12 - Wind Direction Malfunctionsgp30ebbrE12.b1
D950815.2SGP/EBBR/E13 - Low Battery Voltage and AEM Left on Manualsgp30ebbrE13.b1
D950816.2SGP/EBBR/E12 - AEM Failuresgp30ebbrE12.b1
D950816.3SGP/EBBR/E15 - AEM Home 15 Values Highsgp30ebbrE15.b1
D950828.1SGP/EBBR/E13 - Battery Voltage Dropsgp30ebbrE13.b1
D950908.1SGP/EBBR/E15 - AEM Not Exchangingsgp30ebbrE15.b1
D950908.3SGP/EBBR/E12 - Wind Direction Malfunctionsgp30ebbrE12.b1
D950921.2SGP/EBBR/E15 - AEM Replacedsgp30ebbrE15.b1
D950921.3SGP/EBBR/E12 - AEM replacementsgp30ebbrE12.b1
D951113.1SGP/EBBR/E13 - Wind Direction Set Pin Slippagesgp30ebbrE13.b1
D951113.6SGP/EBBR/E13 - Battery voltage dropsgp30ebbrE13.b1
D951116.1SGP/EBBR/E13 - AEM Exchange Stopped in Snow and Freezing Rainsgp30ebbrE13.b1
D951116.4SGP/EBBR/E15 - AEM Exchange Stopped in Snow and Freezing Rainsgp30ebbrE15.b1
D951127.3SGP/EBBR/E12 - AEM Failure/Right Radiation Shield OFFsgp30ebbrE12.b1
D951220.5SGP/EBBR/E15 - Annual calibration changeoutsgp30ebbrE15.b1
D951220.6SGP/EBBR/E13 - battery voltage dropsgp30ebbrE13.b1
D960104.4SGP/EBBR/E15 - Wind Speed Cups Frozensgp30ebbrE15.b1
D960119.1SGP/EBBR/E15 - Reprocess: Soil Temperature Probe Malfunctionsgp30ebbrE15.b1
D960119.2SGP/EBBR/E15 - Battery Voltage Dropsgp30ebbrE15.b1
D960320.3SGP/EBBR/E12 - Wind Speed Cups Frozensgp30ebbrE12.b1
D960508.5SGP/EBBR/E12 - 3-month checksgp30ebbrE12.b1
D960508.6SGP/EBBR/E13 - 3-month checksgp30ebbrE13.b1
D960508.7SGP/EBBR/E15 - 3-month checksgp30ebbrE15.b1
D960606.1SGP/EBBR/E13 - Annual Calibration changeoutsgp30ebbrE13.b1
D961122.11SGP/EBBR/E13 - Wind Direction Incorrectsgp30ebbrE13.b1
D961122.23SGP/EBBR/E12 - EBBR 3 Month Checks - 10 EFssgp30ebbrE12.b1
D961122.24SGP/EBBR/E13 - EBBR 3 Month Checks - 10 EFssgp30ebbrE13.b1
D961122.25SGP/EBBR/E15 - EBBR 3 Month Checks - 10 EFssgp30ebbrE15.b1
D961122.3SGP/EBBR/E12 - Annual Calibration Changeoutsgp30ebbrE12.b1
D961122.8SGP/EBBR/E12 - Left Air Temperature Thermocouple Incorrectsgp30ebbrE12.b1
D961122.9SGP/EBBR/E12 - Battery Voltage Low - Fluxes Affectedsgp30ebbrE12.b1
D970330.1SGP/EBBR/E13 - Frozen Wind Speed Sensorsgp30ebbrE13.b1
D970330.2SGP/EBBR/E15 - Wind Speed Cups frozensgp30ebbrE15.b1
D970401.1Controlled burn at E12 on 3/20/97 and affected datasgp30ebbrE12.b1
D970703.3SGP/EBBR/E15 - Connections Affecting Home Signalssgp30ebbrE15.b1
D970730.2SGP/EBBR/E12 - Wind Direction Sensor Malfunctionssgp30ebbrE12.b1
D970730.3SGP/EBBR/E13 - CR10 Malfunctionsgp30ebbrE13.b1
D971021.4SGP/EBBR/E12 - EBBR Biannual Checkssgp30ebbrE12.b1
D971021.5SGP/EBBR/E13 - EBBR Biannual Checkssgp30ebbrE13.b1
D971021.6SGP/EBBR/E15 - EBBR Biannual Checkssgp30ebbrE15.b1
D980117.14SGP/EBBR/E15 - EBBR Frozen Wind Speedsgp30ebbrE15.b1
D980117.17SGP/EBBR/E12- EBBR Frozen Wind Speedsgp30ebbrE12.b1
D980117.19SGP/EBBR/E13- EBBR Frozen Wind Speedsgp30ebbrE13.b1
D980117.24SGP/EBBR/E15 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp30ebbrE15.b1
D980117.26SGP/EBBR/E12 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp30ebbrE12.b1
D980117.27SGP/EBBR/E13 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp30ebbrE13.b1
D980117.29SGP/EBBR/E15 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affectedsgp30ebbrE15.b1
D980117.32SGP/EBBR/E12 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affectedsgp30ebbrE12.b1
D980117.6SGP/EBBR/E12 - AEM Failure and Replacementsgp30ebbrE12.b1
D980410.8SGP/EBBR/E13 - Wind Speed Sensor Frozensgp30ebbrE13.b1
D980410.9SGP/EBBR/E15 - Wind Speed Sensor Frozensgp30ebbrE15.b1
D980416.11SGP/EBBR/E12 - 3-Month Checksgp30ebbrE12.b1
D980416.12SGP/EBBR/E13 - 3-Month Checksgp30ebbrE13.b1
D980416.13SGP/EBBR/E15 - 3-Month Checksgp30ebbrE15.b1
D980513.4SGP/EBBR/E15 - Pressure Diurnal Fluctuationssgp30ebbrE15.b1
D980513.5SGP/EBBR/E15 - Pressure Too Highsgp30ebbrE15.b1
D980513.6SGP/EBBR/E15 - Left T/RH Probe Temperature Too Largesgp30ebbrE15.b1
D980528.13SGP/EBBR/E12 - Wind Direction Sensor Failuresgp30ebbrE12.b1
D980529.10SGP/EBBR/E13 - Six Month Checkssgp30ebbrE13.b1
D980529.11SGP/EBBR/E15 - Six Month Checkssgp30ebbrE15.b1
D980529.9SGP/EBBR/E12 - Six Month Checkssgp30ebbrE12.b1
D981112.5SGP/EBBR/E13 - Net Radiation Incorrect - Water in Bottom Domesgp30ebbrE13.b1
D981113.3SGP/EBBR/E15 - Aspirator loosened from AEM mountsgp30ebbrE15.b1
D990127.21SGP/EBBR/E12 - Wind Direction Data Incorrect (revised)sgp30ebbrE12.b1
D990127.26SGP/EBBR/E15 - Wind Direction Data Incorrect (revised)sgp30ebbrE15.b1
D990127.32SGP/EBBR/E13 - Wind Speed Data Incorrectsgp30ebbrE13.b1
D990127.33SGP/EBBR - EBBR E13 Wind Speed Data Incorrectsgp30ebbrE13.b1
D990127.34SGP/EBBR - EBBR E13 Wind Speed Data Incorrectsgp30ebbrE13.b1
D990127.44SGP/EBBR/E15 - Wind Speed Data Incorrectsgp30ebbrE15.b1
D990127.45SGP/EBBR - EBBR E15 Wind Speed Data Incorrectsgp30ebbrE15.b1
D990127.46SGP/EBBR - EBBR E15 Wind Speed Data Incorrectsgp30ebbrE15.b1
D990128.1SGP/EBBR/E12 - Wind Speed Data Incorrectsgp30ebbrE12.b1
D990128.2SGP/EBBR - EBBR E12 Wind Speed Data Incorrectsgp30ebbrE12.b1
D990129.1SGP/EBBR - EBBR E12 Wind Speed Data Incorrectsgp30ebbrE12.b1
D990129.2SGP/EBBR/E12 - Data Incorrectsgp30ebbrE12.b1
D990129.3SGP/EBBR/E12 - Temperature, RH, and Vapor Pressure Data Incorrectsgp30ebbrE12.b1
D990129.4SGP/EBBR/E12 - All Temperature Measurements Incorrectsgp30ebbrE12.b1
D990311.1SGP/EBBR/E15 - Temperatures Incorrectsgp30ebbrE15.b1
D990415.1SGP/EBBR/E13 - Wind Speed Frozensgp30ebbrE13.b1
D990622.4SGP/EBBR/E12 - RH top Data Zerosgp30ebbrE12.b1


DQRID : D000221.5
Start DateStart TimeEnd DateEnd Time
08/04/1999221508/10/19991500
Subject:
SGP/EBBR - EBBR E15 Anemometer Cup Off, Wind Speed Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
An anemometer cup fell off.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D000221.8
Start DateStart TimeEnd DateEnd Time
12/21/1999000012/21/19991320
Subject:
SGP/EBBR - EBBR E12 Anemometer Cups Frozen, Wind Speed Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The anemometer cups were frozen stalled during this period.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D000225.10
Start DateStart TimeEnd DateEnd Time
12/17/1999170012/27/19991845
Subject:
SGP/EBBR - EBBR E12 Net Radiation Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Condensation inside the domes (possibly water in the bottom dome also) 
during the period made daytime net radiation values as much as 50% too 
large and nighttime net radiations as much as 100% too small.  

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D000225.2
Start DateStart TimeEnd DateEnd Time
07/27/1999153007/27/19991530
Subject:
SGP/EBBR- EBBR E15 Air Temperatures Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
When the reference temperature sensor was being replaced, the left and
right thermocouple air temperatures and humidity probe temperatures 
were incorrect.

Affected data values were:

5 Minute:  tref, tair_top, tair_bot, thum_top, thum_bot, vp_top, vp_bot
15 minute: rr_tref, rr_thum_l, rr_thum_r, tair_r, tair_l
30 minute: tref, tair_top, tair_bot, thum_top, thum_bot, vp_top, vp_bot,
           bowen, e, h
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • temp_reference
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D000225.7
Start DateStart TimeEnd DateEnd Time
01/13/2000211501/13/20002130
Subject:
SGP/EBBR - EBBR E13 Left Aspirator Not Working
DataStreams:sgp30ebbrE13.b1
Description:
A loss of the 12V DC power to the left aspirator caused it to stop
operating.  The affected measurements are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, h, e
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D000301.1
Start DateStart TimeEnd DateEnd Time
12/09/1999070012/14/19991500
Subject:
SGP/EBBR - EBBR E12 Net Radiation Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D000301.3
Start DateStart TimeEnd DateEnd Time
09/20/1999193009/23/19991930
Subject:
SGP/EBBR - EBBR E13 Net Radiation Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D000531.4
Start DateStart TimeEnd DateEnd Time
07/17/1995220007/24/19952300
Subject:
SGP/EBBR/E13 - failure of sensors
DataStreams:sgp30ebbrE13.b1
Description:
A lightning strike to the central cluster area shortly after 0800 GMT
on July 17 caused failure of several EBBR sensors: both humidity probes,
the barometer, soil heat flux #3, soil moisture # 1 and the wind
direction.
These failed sensors caused sensible, latent, and average soil heat flux
to be incorrect until site operations performed maintenance on July 24th.

Site Operations found a loose connection from soil moisture probe #1, 
removed barometer SN 6578 and replaced it with SN 6507, removed soil heat 
flux sensor #3 with SN 923022 and replaced it with SN 933199, repositioned 
the wind direction sensor - which was rotated approximately ninety degrees 
clockwise from its proper position, and removed the right humidity probe 
SN 460412 and replaced it with SN 460428.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D000531.5
Start DateStart TimeEnd DateEnd Time
07/17/1995220009/22/19952108
Subject:
SGP/EBBR/E13 - Failed Right Humidity Probe
DataStreams:sgp30ebbrE13.b1
Description:
A lightning strike to the central cluster area on 17 July 1995 caused
failure of several EBBR sensors including the right humidity probe.
On July 24th, site operations removed the right humidity probe SN 460412 and 
replaced it with SN 460428

In less than a day the right humidity probe output soared to over 113% and
has hovered around 112% since.  I consider all right probe values to be
incorrect due to this behavior.

Without a properly functioning right humidity probe, all values of top and
bottom relative humidity, top and bottom vapor pressure, Bowen
ratio, and latent and sensible heat fluxes are incorrect.

A working spare relative humidity probe was not available at that time.
The probe was replaced with a working, calibrated probe on 22 September 1995
at about 2108 GMT.  I have the examined the data since the day of the
replacement and find that the new probe is working well.  All E13 EBBR
measurements are presently correct.  The old probe S/N was 460428, the new
S/N is 460413.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D000628.1
Start DateStart TimeEnd DateEnd Time
07/17/1995220007/25/19951930
Subject:
SGP/EBBR/E13- Left humidity probe replaced
DataStreams:sgp30ebbrE13.b1
Description:
A lightning strike to the central cluster area on 17 July 1995 caused the
left humidity probe to fail.  Some of the period of incorrect data has been
 discussed in D0000531.4.  The left humidity probe was replaced on 25 July 
1995 at 1925 GMT (old SN 460413, new SN 460435).
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010213.1
Start DateStart TimeEnd DateEnd Time
12/11/2000013012/15/20001630
Subject:
SGP/EBBR/E12 - EBBR E12 Wind Speed Iced
DataStreams:sgp30ebbrE12.b1
Description:
The anemometer was frozen stopped by freezing rain; the indicated data is incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D010213.2
Start DateStart TimeEnd DateEnd Time
12/18/2000073012/18/20001115
Subject:
SGP/EBBR/E12 - EBBR E12 Wind Speed Iced
DataStreams:sgp30ebbrE12.b1
Description:
The anemometer was frozen stopped by freezing rain; the indicated data is incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D010213.3
Start DateStart TimeEnd DateEnd Time
12/10/2000213012/12/20001715
Subject:
SGP/EBBR/E15 - EBBR E15 Wind Speed Iced
DataStreams:sgp30ebbrE15.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data is incorrect.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010402.13
Start DateStart TimeEnd DateEnd Time
12/18/2000064512/18/20001101
Subject:
SGP/EBBR/E12 - E12 EBBR Wind Direction Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction vane was frozen stopped in one direction by icing.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D010402.14
Start DateStart TimeEnd DateEnd Time
12/18/2000064512/18/20001101
Subject:
SGP/EBBR/E12 - E12 EBBR Wind Speed Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed sensor cups were frozen stopped by icing.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D010402.16
Start DateStart TimeEnd DateEnd Time
02/01/2000000002/08/20001531
Subject:
SGP/EBBR/E12 - E12 EBBR AEM Stuck - Data Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The AEM became stuck between levels, causing all gradient measurements to be incorrect, 
and thus the latent and sensible heat fluxes and Bowen ratio.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010403.10
Start DateStart TimeEnd DateEnd Time
01/04/2001173001/04/20011731
Subject:
SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The Automatic Exchange Mechanism was stuck inbetween the top and bottom positions.  
Incorrect Bowen ratio, and latent and sensible heat fluxes resulted.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010403.16
Start DateStart TimeEnd DateEnd Time
03/16/2000213003/19/20001701
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Low battery voltage caused all data to be incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.17
Start DateStart TimeEnd DateEnd Time
11/06/2000013011/06/20000431
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Low battery voltage caused all data to be incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.18
Start DateStart TimeEnd DateEnd Time
11/06/2000012011/06/20002255
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.19
Start DateStart TimeEnd DateEnd Time
11/12/2000094511/12/20001116
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.2
Start DateStart TimeEnd DateEnd Time
02/24/2000223002/24/20002231
Subject:
SGP/EBBR/E13 - E13 EBBR Heat Capacities Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The soil heat capacities were incorrect, a result of the missing data from the previous 
half hour.
Measurements:sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2


Back To Table of Contents

DQRID : D010403.20
Start DateStart TimeEnd DateEnd Time
11/13/2000001511/14/20000031
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.22
Start DateStart TimeEnd DateEnd Time
02/28/2000123002/28/20001231
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.24
Start DateStart TimeEnd DateEnd Time
02/29/2000130002/29/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data were incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.3
Start DateStart TimeEnd DateEnd Time
02/01/2000000002/23/20001431
Subject:
SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The Automatic Exchange Mechanism was stuck inbetween the top and bottom positions.  
Incorrect Bowen ratio, and latent and sensible heat fluxes resulted.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010403.35
Start DateStart TimeEnd DateEnd Time
03/12/2000130003/12/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.36
Start DateStart TimeEnd DateEnd Time
03/11/2000130003/11/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.37
Start DateStart TimeEnd DateEnd Time
03/08/2000130003/08/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.38
Start DateStart TimeEnd DateEnd Time
03/05/2000130003/05/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.39
Start DateStart TimeEnd DateEnd Time
03/01/2000130003/01/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.4
Start DateStart TimeEnd DateEnd Time
03/03/2000000003/04/20001501
Subject:
SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The Automatic Exchange Mechanism was stuck inbetween the top and bottom positions.  
Incorrect Bowen ratio, and latent and sensible heat fluxes resulted.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010403.40
Start DateStart TimeEnd DateEnd Time
03/13/2000130003/13/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.41
Start DateStart TimeEnd DateEnd Time
03/15/2000130003/15/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.42
Start DateStart TimeEnd DateEnd Time
03/22/2000130003/22/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.43
Start DateStart TimeEnd DateEnd Time
03/23/2000130003/23/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.44
Start DateStart TimeEnd DateEnd Time
03/26/2000130003/26/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.45
Start DateStart TimeEnd DateEnd Time
03/27/2000130003/27/20001301
Subject:
SGP/EBBR/E13 - E13 EBBR All Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Battery voltage was too low.  All data was incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D010403.6
Start DateStart TimeEnd DateEnd Time
03/17/2000173003/23/20001901
Subject:
SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The Automatic Exchange Mechanism was stuck inbetween the top and bottom positions.  
Incorrect Bowen ratio, and latent and sensible heat fluxes resulted.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010403.8
Start DateStart TimeEnd DateEnd Time
12/14/2000020012/14/20002301
Subject:
SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The Automatic Exchange Mechanism was stuck inbetween the top and bottom positions.  
Incorrect Bowen ratio, and latent and sensible heat fluxes resulted.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010403.9
Start DateStart TimeEnd DateEnd Time
12/31/2000230012/31/20002331
Subject:
SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The Automatic Exchange Mechanism was stuck inbetween the top and bottom positions.  
Incorrect Bowen ratio, and latent and sensible heat fluxes resulted.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010412.1
Start DateStart TimeEnd DateEnd Time
02/01/2000000012/31/20000000
Subject:
SGP/EBBR/E13 - E13 EBBR Soil Temperature #4 Suspect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Temperature #4 produced noisy measurements, resulting in quantities
calculated from it to be of suspect quality.  This condition normally 
occurred early in the GMT day.  Sensible (h) and latent (e) heat fluxes
were not normally greatly affected.  Average surface heat flow was normally
slightly underestimated.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • soil_heat_capacity_4
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010413.1
Start DateStart TimeEnd DateEnd Time
12/11/2000000012/14/20001931
Subject:
SGP/EBBR/E13 - E13 EBBR Wind Direction Iced
DataStreams:sgp30ebbrE13.b1
Description:
The wind direction sensor was iced stopped for the indicated period.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D010413.2
Start DateStart TimeEnd DateEnd Time
08/13/2000193001/12/20012001
Subject:
SGP/EBBR/E13 - E13 EBBR Soil Heat Flow #4 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Heat Flow #4 was large positive or negative, but always
incorrect during the indicated period. This resulted in overestimates
or underestimates of laetnt and sensible heat fluxes and average
soil heat flow.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • corr_soil_heat_flow_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010413.3
Start DateStart TimeEnd DateEnd Time
02/27/2000143002/29/20000231
02/05/2000150002/06/20001231
02/23/2000030002/23/20002001
02/19/2000170002/20/20000201
03/01/2000143003/04/20000801
03/04/2000143003/07/20001601
02/24/2000020002/24/20001501
02/08/2000150002/10/20001931
03/11/2000153003/12/20000331
02/20/2000153002/21/20001701
03/12/2000143003/16/20001831
02/01/2000173002/05/20000131
02/29/2000163003/01/20000931
03/17/2000180003/21/20001531
02/06/2000143002/08/20000701
02/25/2000003002/27/20000501
Subject:
SGP/EBBR/E15 - E15 EBBR Reference Temperature Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The reference temperature was incorrect during the indicated periods.  This
temperature is used to adjust air temperature measurements; therefore air
temperature and resulting sensible and latent heat fluxes and Bowen ratio 
are incorrect.
Measurements:sgp30ebbrE15.b1:
  • temp_reference
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010413.4
Start DateStart TimeEnd DateEnd Time
03/17/2000170003/17/20001701
Subject:
SGP/EBBR/E15 - E15 EBBR Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
All of the measurements (except, battery voltage, time_offset, lat, lon, etc.) were 
incorrect during the installation of a new reference temperature sensor.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D010413.5
Start DateStart TimeEnd DateEnd Time
03/17/2000160003/17/20001631
Subject:
SGP/EBBR/E15 - E15 EBBR Data Missing
DataStreams:sgp30ebbrE15.b1
Description:
The data for this period was missing, during replacement of the reference temperature 
sensor.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D010413.6
Start DateStart TimeEnd DateEnd Time
04/04/2000153004/04/20001531
Subject:
SGP/EBBR/E15 - E15 EBBR Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
All of the measurements (except, battery voltage, time_offset, lat, lon, etc.) were 
incorrect during a logger upgrade.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D010413.7
Start DateStart TimeEnd DateEnd Time
04/04/2000150004/04/20001501
Subject:
SGP/EBBR/E15 - E15 EBBR Data Missing
DataStreams:sgp30ebbrE15.b1
Description:
The data for this period was missing, during an upgrade of the data logger.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D010413.8
Start DateStart TimeEnd DateEnd Time
03/17/2000013003/17/20000331
Subject:
SGP/EBBR/E15 - E15 EBBR Some Soil Temperatures and Heat Flows Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
For an unknown reason, some of the soil temperatures and soil heat flows
were incorrect, leading to many of the calculated quantities being incorrect.
Measurements:sgp30ebbrE15.b1:
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5


Back To Table of Contents

DQRID : D010413.9
Start DateStart TimeEnd DateEnd Time
04/04/2000183004/04/20001831
Subject:
SGP/EBBR/E15 - E15 EBBR Some Soils and Flux Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The soil heat capacity measurements were incorrect for an unknown reason, resulting in 
incorrect average soil heat flow and latent and sensible heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • energy_storage_change_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D010416.1
Start DateStart TimeEnd DateEnd Time
12/31/2000193001/09/20011701
09/21/2000013009/22/20001331
09/22/2000230010/03/20001531
Subject:
SGP/EBBR/E15 - E15 EBBR AEM Stuck in Middle
DataStreams:sgp30ebbrE15.b1
Description:
When the AEM does not complete switching and becomes hung at a mid
position, the indicated data measurements are incorrect.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D010416.2
Start DateStart TimeEnd DateEnd Time
10/03/2000154510/03/20001815
Subject:
SGP/EBBR/E15 - E15 EBBR AEM Replacement
DataStreams:sgp30ebbrE15.b1
Description:
Large home signals occured while the AEM was being replaced; 
the indicated data measurements are incorrect.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D010416.3
Start DateStart TimeEnd DateEnd Time
10/04/2000104510/04/20001316
10/05/2000070010/05/20001601
10/05/2000170010/05/20001901
Subject:
SGP/EBBR/E15 - E15 EBBR Battery Voltage Low
DataStreams:sgp30ebbrE15.b1
Description:
When EBBR battery voltage is 10.4 volts or less, the measurements
are considered to be incorrect.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D010416.4
Start DateStart TimeEnd DateEnd Time
10/15/2000073010/17/20001516
Subject:
SGP/EBBR/E15 - E15 EBBR Incorrect Net Radiation
DataStreams:sgp30ebbrE15.b1
Description:
Incorrect net radiation resulted in incorrect sensible and latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010605.5
Start DateStart TimeEnd DateEnd Time
09/29/1999000003/08/20011931
Subject:
SGP EBBR E13 - E13 EBBR Soil T #4 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Temperature #4 floated around, causing average soil heat flow
to sometimes be too small (resulting too small a sensible heat flux and
too large a latent heat flux) or too large (resulting in too large a 
sensible heat flux and too small a latent heat flux).  Investigation of
g4 will indicate when these conditions occurred and the likely effect on
sensible and latent heat fluxes.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D011127.26
Start DateStart TimeEnd DateEnd Time
04/03/2001162504/03/20011716
10/18/2001193010/18/20012116
Subject:
SGP EBBR E12 - E12 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE12.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D011127.27
Start DateStart TimeEnd DateEnd Time
10/04/2001183510/04/20011934
04/20/2001172004/20/20011749
Subject:
SGP EBBR E13 - E13 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • soil_moisture_4
  • energy_storage_change_2
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D011127.28
Start DateStart TimeEnd DateEnd Time
04/17/2001185004/17/20011945
10/02/2001160410/02/20011742
Subject:
SGP EBBR E15 - E15 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D011207.11
Start DateStart TimeEnd DateEnd Time
04/16/2001190004/17/20011631
04/20/2001213004/21/20010931
04/27/2001003005/01/20011431
04/21/2001203004/26/20011501
04/17/2001233004/18/20011631
04/06/2001203004/11/20011731
04/18/2001210004/20/20011301
Subject:
SGP EBBR E12 - E12 EBBR Data Incorrect From AEM In One Position
DataStreams:sgp30ebbrE12.b1
Description:
The AEM kept stopping in one position. Offset biases are not removed from the 
gradient data in this situation and the data indicated is therefore incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D011207.12
Start DateStart TimeEnd DateEnd Time
05/27/2001173506/26/20011501
Subject:
SGP EBBR E15 - E15 EBBR Battery Voltage Low, Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
When the battery voltage is 10.4 volts or below, all selected data should be considered to 
be incorrect.  See the battery voltage in the 15 minute data to determine times of 
incorrect data.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D011218.1
Start DateStart TimeEnd DateEnd Time
10/11/2001193010/11/20011931
Subject:
SGP EBBR E15 - E15 EBBR Data Zeros Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The data was all zeros after a logger restart for 5 , 15, and 30 minute periods.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D020129.1
Start DateStart TimeEnd DateEnd Time
10/11/2001150810/11/20011931
Subject:
SGP EBBR E15 - E15 EBBR Recalibration Changeout
DataStreams:sgp30ebbrE15.b1
Description:
During the indicated period the EBBR unit was being changed out with a
recalibrated unit.  All data is incorrect or missing.

Unit #14 was removed; #6 was installed.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D020129.10
Start DateStart TimeEnd DateEnd Time
10/05/2001170001/18/20020001
Subject:
SGP/EBBR/E13 - Reprocess: E13 EBBR Soil heat Flows #1 and #2 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Heat Flow probes #1 and #2 were incorrect during the
indicated period (and for some time afterward, to be covered in another
DQR).  Outputs from the probes were typically too large negative or 
too large positive.
Measurements:sgp30ebbrE13.b1:
  • soil_heat_flow_2
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_1
  • corr_soil_heat_flow_1


Back To Table of Contents

DQRID : D020129.11
Start DateStart TimeEnd DateEnd Time
10/05/2001171510/05/20011731
Subject:
SGP EBBR E13 - E13 EBBR Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The 5 and 15 minute data was zero and thus the thirty minute data was
also incorrect.  This occurs after the restart of an EBBR system, in
this case after a recalibration unit changeout.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D020129.12
Start DateStart TimeEnd DateEnd Time
10/08/2001200010/12/20011731
Subject:
SGP EBBR E13 - E13 EBBR Left T/RH Probe Temperature Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The left T/RH Probe Temperature was often incorrect, causing the other indicated
measurements to be incorrect also.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.13
Start DateStart TimeEnd DateEnd Time
01/07/2002233001/07/20022331
01/06/2002193001/06/20022101
01/09/2002033001/18/20020001
01/08/2002173001/08/20021801
01/05/2002193001/05/20021931
10/12/2001173510/18/20011601
11/22/2001013011/25/20011531
Subject:
SGP EBBR E13 - E13 EBBR Left T/RH Probe Temperature Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The left T/RH Probe Temperature was often incorrect, causing the other indicated
measurements to be incorrect also.  

When the home30 signal had an offset, the top RH probe temperature was incorrect
but not the bottom RH probe temperature.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.2
Start DateStart TimeEnd DateEnd Time
11/25/2001154512/28/20011931
10/09/2001024510/09/20012145
Subject:
SGP EBBR E13 - E13 EBBR AEM in Mid Position
DataStreams:sgp30ebbrE13.b1
Description:
The AEM stopped before reaching the end of it's travel,
causing the home signals to be between 0 and 3 during 
much of this period (therefore the data is colored yellow).  

All gradient data, sensible heat flux, latent heat flux,
and the Bowen ratio are incorrect during this condition.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.3
Start DateStart TimeEnd DateEnd Time
12/28/2001193001/18/20020001
10/12/2001131511/25/20011541
Subject:
SGP EBBR E13 - E13 EBBR AEM Home 30 Offset
DataStreams:sgp30ebbrE13.b1
Description:
The AEM home30 signal is offset by approximately 25;
it appears that the electronics of the AEM is adding
the home15 and home30 voltages together when the AEM is
in the home30 position.

All gradient data, sensible heat flux, latent heat flux,
and the Bowen ratio are incorrect during this condition.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.4
Start DateStart TimeEnd DateEnd Time
10/09/2001224510/12/20011301
Subject:
SGP EBBR E13 - E13 EBBR AEM Home 30 Offset or AEM in Mid Position
DataStreams:sgp30ebbrE13.b1
Description:
The AEM stopped before reaching the end of it's travel,
causing the home signals to be between 0 and 3 during 
part of this period.

The AEM home30 signal is offset by approximately 25 
during part of this period; it appears that the electronics 
of the AEM is adding the home15 and home30 voltages 
together when the AEM is in the home30 position.

All gradient data, sensible heat flux, latent heat flux,
and the Bowen ratio are incorrect during these conditions.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.5
Start DateStart TimeEnd DateEnd Time
04/01/2001000010/05/20011401
Subject:
SGP EBBR E13 - E13 EBBR Left Air Temperature Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
This condition occurred most of the time during the 
indicated period (hence color yellow).

The left air temperature was incorrect only when the AEM
was in the home 30 position.  This only affected the bottom
air temperature calculation.  However, it made the latent
heat flux, sensible heat flux, and Bowen ratio incorrect.

The sensor was improperly inserted into the aspirator shield
and was pinched between the shield and the T/RH probe. When
the AEM was in the home30 position, the aspirator hose
position may have caused the sensor to short to ground.
Measurements:sgp30ebbrE13.b1:
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.7
Start DateStart TimeEnd DateEnd Time
01/25/2001053003/01/20012356
Subject:
SGP EBBR E13 - E13 EBBR Left Air Temperature Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
This condition occurred most of the time during the 
indicated period (hence color yellow).

The left air temperature was incorrect only when the AEM
was in the home 30 position.  This only affected the bottom
air temperature calculation.  However, it made the latent
heat flux, sensible heat flux, and Bowen ratio incorrect.

The sensor was improperly inserted into the aspirator shield
and was pinched between the shield and the T/RH probe. When
the AEM was in the home30 position, the aspirator hose
position may have caused the sensor to short to ground.
Measurements:sgp30ebbrE13.b1:
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.8
Start DateStart TimeEnd DateEnd Time
03/08/2001193503/31/20012356
Subject:
SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Temperature #4 was often incorrect, typically too large negative,
during this period, causing other measurements calculated with
it to be incorrect also. This was caused by a bad multiplexor channel,
which was discovered by the vendor during recalibration of the unit
later.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020129.9
Start DateStart TimeEnd DateEnd Time
04/01/2001000010/05/20011401
Subject:
SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Temperature #4 was often incorrect, typically too large negative,
during this period, causing other measurements calculated with
it to be incorrect also. This was caused by a bad multiplexor channel,
which was discovered by the vendor during recalibration of the unit
later.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020131.13
Start DateStart TimeEnd DateEnd Time
11/25/2001154512/28/20011931
Subject:
SGP/EBBR/E13 - Left T/RH Probe Temperature Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
During much of the indicated period the Left T/RH Temperature was
incorrect.  Because the home signal was between 0 and 3, the 
temperature was incorrect when the AEM was at the bottom position,
but was correct when the AEM was at the top position.  This was caused by
a short created when the sensor was mispositioned in the aspirator
housing and enough strain on the cable for it to bring it into contact
with the housing in the bottom position.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020214.1
Start DateStart TimeEnd DateEnd Time
01/18/2002000501/25/20022201
Subject:
SGP/EBBR/E13 - Left Humidity Probe Temperature Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The left humidity probe temperature was incorrect
much of the time, as was the top humidity temperature and
vapor pressure.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020214.2
Start DateStart TimeEnd DateEnd Time
01/25/2002220001/25/20022201
Subject:
SGP/EBBR/E13 - Data incorrect during maintenance
DataStreams:sgp30ebbrE13.b1
Description:
The 5, 15, and 30 minute measurements were zero or
offscale at 2200 GMT only.  Electronic connections
were being checked at that time.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D020214.5
Start DateStart TimeEnd DateEnd Time
01/25/2002201001/25/20022101
Subject:
SGP/EBBR/E13 - Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
The measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D020214.7
Start DateStart TimeEnd DateEnd Time
11/13/2001170011/13/20011801
Subject:
SGP/EBBR/E15 - Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D020628.1
Start DateStart TimeEnd DateEnd Time
10/14/1995140010/14/19951700
Subject:
SGP/EBBR/E12 - 3-month Check
DataStreams:sgp30ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D020628.15
Start DateStart TimeEnd DateEnd Time
11/23/1994151511/23/19941630
Subject:
SGP/EBBR/E12 - T/RH Check
DataStreams:sgp30ebbrE12.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields
5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  1515, 1520, 1525, 1530, 1535, 1540, 1545, 1550, 1555,
           1600, 1605, 1610
15 minute: 1515, 1530, 1545, 1600, 1615
30 minute: 1530, 1600, 1630

(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D020628.16
Start DateStart TimeEnd DateEnd Time
11/04/1994200511/04/19942100
Subject:
SGP/EBBR/E13 - T/RH Check
DataStreams:sgp30ebbrE13.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields
5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  2005, 2010, 2015, 2020, 2025, 2030, 2035, 2040, 2045,
           2050, 2055, 2100, 2105
15 minute: 2015, 2045, 2100, 2115
30 minute: 2030, 2100

(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020628.17
Start DateStart TimeEnd DateEnd Time
11/07/1994165011/07/19941830
Subject:
SGP/EBBR/E15 - T/RH Check
DataStreams:sgp30ebbrE15.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  1650, 1655, 1700, 1705, 1710, 1715, 1720, 1725, 1730,
           1735, 1740, 1745, 1750, 1755, 1800, 1805
15 minute: 1700, 1715, 1730, 1745, 1800, 1815
30 minute: 1700, 1730, 1800, 1830

(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D020628.2
Start DateStart TimeEnd DateEnd Time
10/06/1995000010/06/19952359
Subject:
SGP/EBBR/E13 - 3-month Check
DataStreams:sgp30ebbrE13.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.

Time of the check is not known, so the entire day has been flagged as
suspect.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020628.3
Start DateStart TimeEnd DateEnd Time
10/10/1995180010/10/19952100
Subject:
SGP/EBBR/E15 - 3-month Check
DataStreams:sgp30ebbrE15.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D020716.11
Start DateStart TimeEnd DateEnd Time
04/30/2002154004/30/20021611
Subject:
SGP/EBBR/E12 - 6 Month Checks
DataStreams:sgp30ebbrE12.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D020716.12
Start DateStart TimeEnd DateEnd Time
05/16/2002185505/16/20021926
Subject:
SGP/EBBR/E13 - 6 Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020716.13
Start DateStart TimeEnd DateEnd Time
05/14/2002150505/14/20021546
Subject:
SGP/EBBR/E15 - 6 Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D020717.10
Start DateStart TimeEnd DateEnd Time
01/30/2002043002/06/20021646
Subject:
SGP/EBBR/E12 - AEM Hung
DataStreams:sgp30ebbrE12.b1
Description:
The automatic exchange mechanism did not exchange properly, causing other measurements to 
be incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D020717.11
Start DateStart TimeEnd DateEnd Time
06/12/2002143006/12/20021501
Subject:
SGP/EBBR/E12 - Measurements Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
All measurements were incorrect or offscale for an unknown reason.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D020717.12
Start DateStart TimeEnd DateEnd Time
06/28/2002180007/07/20022356
Subject:
SGP/EBBR/E12 - Resistance Measurements Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
All sensors that depend on resistance measurements are incorrect.
Average soil heat flow, sensible heat flux, and latent heat flux are incorrect as a 
result.

This condition normally occurs when the reference temperature sensor is disconnected or 
bad.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • bowen_ratio
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_3
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_4
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • soil_moisture_1
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • surface_soil_heat_flux_4
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • soil_moisture_4
  • soil_moisture_3
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_moisture_2
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_heat_capacity_5
  • energy_storage_change_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D020717.13
Start DateStart TimeEnd DateEnd Time
01/25/2002220203/03/20021129
Subject:
SGP/EBBR/E13 - Reprocess: Soil Heat Flow #1 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Heat Flow #1 was incorrect during the indicated period.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
   ave_shf = (g2 + g3 + g4 + g5)/4
   e = -(q + ave_shf)/(1 + bowen)
   h = -(q + e + ave_shf)
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_1
  • corr_soil_heat_flow_1


Back To Table of Contents

DQRID : D020717.14
Start DateStart TimeEnd DateEnd Time
03/07/2002203205/20/20022101
Subject:
SGP/EBBR/E13 - Reprocess: Soil Heat Flow #2 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Heat Flow #2 was incorrect during the indicated period.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
   ave_shf = (g1 + g3 + g4 + g5)/4
   e = -(q + ave_shf)/(1 + bowen)
   h = -(q + e + ave_shf)
Measurements:sgp30ebbrE13.b1:
  • soil_heat_flow_2
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020717.15
Start DateStart TimeEnd DateEnd Time
10/05/2001171502/22/20022131
Subject:
SGP/EBBR/E13 - Wrong CR10 Program Installed
DataStreams:sgp30ebbrE13.b1
Description:
An old version 4 program was installed on 5 Oct 01 instead of the correct version 8 
program.
All of the indicated measurements are suspect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • soil_moisture_4
  • energy_storage_change_2
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D020717.16
Start DateStart TimeEnd DateEnd Time
05/24/2002060006/14/20021431
Subject:
SGP/EBBR/E13 - Wind Direction Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The wind direction and sigma_wd was near zero for the indicated times.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D020717.17
Start DateStart TimeEnd DateEnd Time
03/08/2002141503/09/20020931
05/07/2002170005/07/20021731
04/16/2002143004/16/20022001
01/18/2002001503/03/20020801
03/12/2002000003/12/20020101
05/07/2002040005/07/20020401
05/06/2002060005/06/20021931
04/17/2002153004/17/20021701
05/07/2002000005/07/20020001
03/09/2002094503/09/20022001
05/07/2002030005/07/20020301
05/11/2002153005/11/20021601
04/16/2002223004/17/20020031
03/03/2002081503/08/20021401
05/11/2002190005/11/20021901
03/12/2002011504/12/20021901
04/17/2002223004/17/20022231
05/08/2002230005/09/20020101
04/18/2002123004/18/20021231
Subject:
SGP/EBBR/E13 - AEM Hung up
DataStreams:sgp30ebbrE13.b1
Description:
The automatic exchange mechanism hung numerous times, but with various different 
measurements of home signals.  In all cases, temperature and humidity gradients were incorrect; 
thus the Bowen ratio, sensible heat flux, and latent heat flux are incorrect for the 
indicated periods.  Even when the home 15 and 30 signals were different (but too high) the 
measurements were incorrect because the program keys off of the home signals, which must be 
in the proper ranges.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020717.6
Start DateStart TimeEnd DateEnd Time
11/01/2001000006/20/20021231
Subject:
SGP/EBBR/E12 - Reprocess: Soil Temperature #3 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil Temperature #3 was flaky primarily during nighttime hours and sometimes during early 
daylight hours.  Average soil heat flow, sensible heat flux, and latent heat flux are 
also affected; these can be recalculated using the remaining good sets of soil sensors as 
follows:

The heat fluxes can be recalculated by using soil sets 1, 2, 4, and 5 as follows:
     ave_shf = (g1 + g2 + g4 + g5)/4
     e = -(q + ave_shf)/(1 + bowen)
     h = -(q + e + ave_shf)
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Soil temperature mean 3(soil_temp_3)
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D020717.7
Start DateStart TimeEnd DateEnd Time
04/25/2002223006/30/20022356
Subject:
SGP/EBBR/E12 - Wind Direction Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction measurement was zero, in the 50s, or always less than 180 degrees.

A DQPR has been issued to resolve the problem.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D020717.8
Start DateStart TimeEnd DateEnd Time
01/30/2002120001/30/20021201
Subject:
SGP/EBBR/E12 - Reprocess: Soil Moisture 4 and 5 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil moisture measurements from sets 4 and 5 were incorrect, leading to many other 
incorrect measurements calculated using them.

Average soil heat flow, sensible heat flux, and latent heat flux are affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
    ave_shf = (g1 + g2 + g3)/3
    e = -(q + ave_shf)/(1 + bowen)
    h = -(q + e + ave_shf)

Note:  D020717.6 reports Soil temperature sensor #3 was also bad during this
time, but for the very specific records affected by the soil moisture #4 and
#5 reporting incorrectly, soil temp #3 was okay.  Therefore the equations
given are correct.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_capacity_4
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_moisture_4
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D020717.9
Start DateStart TimeEnd DateEnd Time
01/30/2002143001/30/20021431
Subject:
SGP/EBBR/E12 - Reprocess: Soil Moisture 2 and 5 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil moisture measurements from sets 2 and 5 were incorrect, leading to many other 
incorrect measurements calculated using them.

Average soil heat flow, sensible heat flux, and latent heat flux are affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
    ave_shf = (g1 + g3 + g4)/3
    e = -(q + ave_shf)/(1 + bowen)
    h = -(q + e + ave_shf)

Note:  D020717.6 reports Soil temperature sensor #3 was also bad during this
time, but for the very specific records affected by the soil moisture #2 and
#5 reporting incorrectly, soil temp #3 was okay.  Therefore the equations
given are correct.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • corr_soil_heat_flow_2
  • soil_heat_capacity_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • soil_moisture_2


Back To Table of Contents

DQRID : D020723.1
Start DateStart TimeEnd DateEnd Time
12/22/1995203012/22/19952130
Subject:
SGP/EBBR/E13 - Thermocouple out of range, data incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The left thermocouple temperature for 22 December was out of range
between 2030 and 2130 GMT, yielding incorrect values as listed below:

5 minute:  tair_top, tair_bot
15 minute: tair_l
30 minute:  tair_top, tair_bot, bowen, h, e
Measurements:sgp30ebbrE13.b1:
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020726.2
Start DateStart TimeEnd DateEnd Time
01/18/2002001501/25/20022201
03/03/2002113003/07/20022031
Subject:
SGP/EBBR/E13 - Reprocess: Soil Heat Flow #1 and #2 Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Soil Heat Flow #1 and #2 were incorrect during the indicated period.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
   ave_shf = (g3 + g4 + g5)/3
   e = -(q + ave_shf)/(1 + bowen)
   h = -(q + e + ave_shf)
Measurements:sgp30ebbrE13.b1:
  • soil_heat_flow_2
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_1
  • corr_soil_heat_flow_1


Back To Table of Contents

DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE15.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE15.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2


Back To Table of Contents

DQRID : D021113.2
Start DateStart TimeEnd DateEnd Time
10/01/1995000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30baebbrE13.c1, sgp30baebbrE15.c1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30baebbrE13.c1:
  • cs4
  • cs1
  • cs5
  • cs2
  • cs3

sgp30baebbrE15.c1:
  • cs4
  • cs5
  • cs1
  • cs3
  • cs2


Back To Table of Contents

DQRID : D021113.3
Start DateStart TimeEnd DateEnd Time
10/04/1995000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30baebbrE12.c1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30baebbrE12.c1:
  • cs2
  • cs1
  • cs4
  • cs3
  • cs5


Back To Table of Contents

DQRID : D021113.4
Start DateStart TimeEnd DateEnd Time
12/01/1993120006/18/20031159
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE12.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.
   
This does not affect the data quality.

(NOTE: The actual begin date of some of these data streams
 is as early as 7/4/93.  This DQR applies to all 30m EBBR
 data.)
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE15.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2


Back To Table of Contents

DQRID : D030110.33
Start DateStart TimeEnd DateEnd Time
08/20/2002160008/20/20021630
11/25/2002181511/25/20021845
Subject:
SGP/EBBR/E12 - Data Incorrect during 6 month checks
DataStreams:sgp30ebbrE12.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D030110.34
Start DateStart TimeEnd DateEnd Time
11/14/2002201511/14/20022045
Subject:
SGP/EBBR/E13 - Data Incorrect during 6 month checks
DataStreams:sgp30ebbrE13.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D030110.35
Start DateStart TimeEnd DateEnd Time
11/12/2002171011/12/20021740
Subject:
SGP/EBBR/E15 - Data Incorrect during 6 month checks
DataStreams:sgp30ebbrE15.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030114.11
Start DateStart TimeEnd DateEnd Time
07/08/2002000007/09/20021330
Subject:
SGP/EBBR/E12 - Resistance-based Measurements Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
When the Reference Temperature in the EBBR 
enclosure is not reported correctly, it
affects all resistance-based measurements
that are adjusted with the temperature of 
the reference junction.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • vapor_pressure_bottom
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • bowen_ratio
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_3
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_4
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • soil_moisture_1
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • surface_soil_heat_flux_4
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • soil_moisture_4
  • soil_moisture_3
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_moisture_2
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_heat_capacity_5
  • energy_storage_change_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030114.12
Start DateStart TimeEnd DateEnd Time
07/01/2002000007/12/20021800
Subject:
SGP/EBBR/E12 - Wind Direction Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D030114.13
Start DateStart TimeEnd DateEnd Time
07/23/2002170007/23/20021729
09/03/2002170009/03/20021729
08/16/2002160008/16/20021629
Subject:
SGP/EBBR/E12 - Data zero following Logger Restart
DataStreams:sgp30ebbrE12.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.  The restart on 08/16/02 occurred after an EBBR
unit changeout.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030114.14
Start DateStart TimeEnd DateEnd Time
09/09/2002000010/29/20021830
Subject:
SGP/EBBR/E12 - Battery Voltage Low
DataStreams:sgp30ebbrE12.b1
Description:
Normally, when Battery Voltage drops below 10.5 volts, most 
measurements are suspect and some are often incorrect.
In this particular case, some of the data is suspect when
the battery voltage is below 11.0 volts.

Soil Heat Flow #3 is normally affected first, with other 
measurements following at lower voltages.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030114.19
Start DateStart TimeEnd DateEnd Time
11/25/2002183011/25/20021900
10/31/2002070011/12/20021730
Subject:
SGP/EBBR/E12 - AEM Stuck in One Position
DataStreams:sgp30ebbrE12.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
at a home position, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030115.2
Start DateStart TimeEnd DateEnd Time
08/16/2002172012/10/20021720
Subject:
SGP/EBBR/E12 - Reprocess: Net Rad Calibration Coefficients
DataStreams:sgp30ebbrE12.b1
Description:
The Net Radiometer coefficients were incorrect in the CR10
program when the replacement EBBR unit was installed on
08/16/02.

The data can be easily corrected; see the Suggestion area below.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D030115.3
Start DateStart TimeEnd DateEnd Time
12/10/2002170012/10/20021729
Subject:
SGP/EBBR/E12 - Data Mostly Zero Following Logger Restart
DataStreams:sgp30ebbrE12.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.

The restart on 12/10/02 occurred after a CR10
program change of net radiometer coefficients 
and subsequent restart of the CR10.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030115.4
Start DateStart TimeEnd DateEnd Time
09/23/2002000010/31/20022130
Subject:
SGP/EBBR/E13 - Wind Speed Stalling at Low Speeds
DataStreams:sgp30ebbrE13.b1
Description:
Perhaps because of excessive bearing wear, the wind speed sensor
had a high starting threshhold with wind speeds below about 2 m/s.
Wind speed measurements at all speeds were probably too low.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D030115.5
Start DateStart TimeEnd DateEnd Time
10/05/2001175002/22/20022100
Subject:
SGP/EBBR/E13 - Reprocess: Soil Moisture #1 Offset1
DataStreams:sgp30ebbrE13.b1
Description:
The wrong offset (1.4656) was used in the calibration coefficients for
Soil Moisture Probe #1. The correct offset is 14.656.

Sensible and Latent Heat Flux measurements are not significantly affected.
Measurements:sgp30ebbrE13.b1:
  • soil_moisture_1


Back To Table of Contents

DQRID : D030115.6
Start DateStart TimeEnd DateEnd Time
09/18/2002121009/19/20020245
Subject:
SGP/EBBR/E13 - AEM Jung between Home Positions
DataStreams:sgp30ebbrE13.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
inbetween home positions, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D030115.7
Start DateStart TimeEnd DateEnd Time
10/11/2001192007/09/20021522
Subject:
SGP/EBBR/E15 - Reprocess: Soil Moisture #1 Offset
DataStreams:sgp30ebbrE15.b1
Description:
The wrong offset (9.5264) was used in the calibration coefficients for
Soil Moisture Probe #1. The correct offset is 0.95264.

Sensible and Latent Heat Flux measurements are not significantly affected.
Measurements:sgp30ebbrE15.b1:
  • soil_moisture_1


Back To Table of Contents

DQRID : D030115.8
Start DateStart TimeEnd DateEnd Time
07/22/2002163007/22/20021659
Subject:
SGP/EBBR/E15 - Data Mostly Zero Following Logger Restart
DataStreams:sgp30ebbrE15.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.  The restart on 07/22/02 occurred after a pressure
sensor replacement.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_1
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • temp_trh_bottom
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D030115.9
Start DateStart TimeEnd DateEnd Time
12/10/2002130012/23/20021600
Subject:
SGP/EBBR/E15 - Pressure Low
DataStreams:sgp30ebbrE15.b1
Description:
The pressure measurements were too low during this period, as much as 40
mb too low.  This occurred after a restart of the
EBBR CR10 datalogger, for unknown reasons.
Measurements:sgp30ebbrE15.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D030711.21
Start DateStart TimeEnd DateEnd Time
02/23/2003153003/04/20031645
01/01/2003000001/10/20031630
02/06/2003173002/18/20031715
04/15/2003164504/15/20031700
Subject:
SGP/EBBR/E12 - AEM Hung Inbetween Home Positions
DataStreams:sgp30ebbrE12.b1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D030712.16
Start DateStart TimeEnd DateEnd Time
04/15/2003163004/15/20031700
Subject:
SGP/EBBR/E12 -  6 Month Checks
DataStreams:sgp30ebbrE12.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D030712.17
Start DateStart TimeEnd DateEnd Time
05/01/2003190505/01/20031935
Subject:
SGP/EBBR/E13 -  6 Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D030712.18
Start DateStart TimeEnd DateEnd Time
04/29/2003154004/29/20031655
Subject:
SGP/EBBR/E15 -  6 Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030724.2
Start DateStart TimeEnd DateEnd Time
10/11/2001193008/05/20031630
Subject:
SGP/EBBR/E15 - Wind Direction 10 Degrees Low
DataStreams:sgp30ebbrE15.b1
Description:
The wind direction at E15 EBBR was 10 degrees low for the period (since
installation of the EBBR unit on 10/11/01). The wind direction sensor was apparently 
aligned to magnetic north instead of true north at installation.
Measurements:sgp30ebbrE15.b1:
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D030728.2
Start DateStart TimeEnd DateEnd Time
06/19/2003190006/19/20031900
Subject:
SGP/EBBR/E15 - Top Humidity reported as zero in 30 minute data.
DataStreams:sgp30ebbrE15.b1
Description:
The top relative humidity was reported as zero in the 30 minute data.
This is an apparent misreporting by the CR10 datalogger or is caused by
a communications problem in accessing the data from the datalogger.  It is very 
infrequently seen; it's actual cause is unknown. No other data was
affected.
Measurements:sgp30ebbrE15.b1:
  • rh_top_fraction


Back To Table of Contents

DQRID : D030919.8
Start DateStart TimeEnd DateEnd Time
04/23/2003183005/01/20032000
Subject:
SGP/EBBR/E13  - Water In Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D031031.2
Start DateStart TimeEnd DateEnd Time
10/11/2003223010/12/20032330
Subject:
SGP/EBBR/E15 - Reference Temperature Failed
DataStreams:sgp30ebbrE15.b1
Description:
The reference temperature failed, making air temperatures,
e, h, and Bowen ratio incorrect.
Measurements:sgp30ebbrE15.b1:
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D031031.4
Start DateStart TimeEnd DateEnd Time
10/14/2003013010/14/20031800
Subject:
SGP/EBBR/E12  - Water in Net Radiometer, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D031031.5
Start DateStart TimeEnd DateEnd Time
09/29/2003180010/02/20031845
Subject:
SGP/EBBR/E13  - Water in Net Radiometer, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D031031.6
Start DateStart TimeEnd DateEnd Time
09/29/2003163009/30/20031600
Subject:
SGP/EBBR/E15  - Water In Net Radiometer, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D031031.9
Start DateStart TimeEnd DateEnd Time
10/11/2003223010/12/20032359
Subject:
SGP/EBBR/E15  - Soil Temperature #5 Incorrect, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Soil Temperature #5 was incorrect.

This affected many measurements, including sensible and latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Soil temperature mean 5(soil_temp_5)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • energy_storage_change_5


Back To Table of Contents

DQRID : D031106.1
Start DateStart TimeEnd DateEnd Time
10/13/2003000010/14/20031830
Subject:
SGP/EBBR/E15 - Soil Temperature #5 Incorrect, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Soil Temperature #5 was incorrect.

This affected many measurements, including sensible and latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Soil temperature mean 5(soil_temp_5)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • energy_storage_change_5


Back To Table of Contents

DQRID : D031110.7
Start DateStart TimeEnd DateEnd Time
11/05/2003140011/11/20031800
Subject:
SGP/EBBR/E15 - AEM Hung Between Home Positions, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The AEM was hung inbetween home positions.

Therefore the sensible and latent heat fluxes are also incorrect.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • home_signal_30
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • home_signal_15
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031124.12
Start DateStart TimeEnd DateEnd Time
10/13/2003000011/26/20032300
Subject:
SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltage
DataStreams:sgp30ebbrE12.b1
Description:
The barometer output was scaling with supply voltage (i.e. it 
               followed the charging of the battery by the solar panel).

               NOTE: The barometer was replaced later than the end date of 
               this DQR.  Why the problem ended on 26 Nov 2003 is unclear; 
               there was no site ops intervention on that date.

               The problem did not affect the sensible and latent heat flux 
               calculations beyond the expected system error.
Measurements:sgp30ebbrE12.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031204.10
Start DateStart TimeEnd DateEnd Time
10/13/2003183010/13/20031900
Subject:
SGP/EBBR/E13 - 6 Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D031204.11
Start DateStart TimeEnd DateEnd Time
10/14/2003170010/14/20031730
Subject:
SGP/EBBR/E15 - 6 Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031204.9
Start DateStart TimeEnd DateEnd Time
10/28/2003175010/28/20031845
Subject:
SGP/EBBR/E12 - 6 Month Checks
DataStreams:sgp30ebbrE12.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D031217.4
Start DateStart TimeEnd DateEnd Time
01/03/2003150010/12/20032355
Subject:
SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltage
DataStreams:sgp30ebbrE12.b1
Description:
The barometer output scaled with supply voltage (it followed the charging of the battery 
by the solar panel).

The problem did not affect the sensible and latent heat flux calculations
beyond the expected system error.
Measurements:sgp30ebbrE12.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031222.15
Start DateStart TimeEnd DateEnd Time
12/09/2003223512/10/20031705
Subject:
SGP/EBBR/E12  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D031222.16
Start DateStart TimeEnd DateEnd Time
12/09/2003214512/10/20030115
Subject:
SGP/EBBR/E13  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D031222.17
Start DateStart TimeEnd DateEnd Time
12/14/2003173012/14/20031830
Subject:
SGP/EBBR/E13  - Net Radiometer Iced Over During Storm
DataStreams:sgp30ebbrE13.b1
Description:
The net radiometer was covered with ice from a storm.  Net radiation values are incorrect, 
and are sometimes even negative during the daytime.  Sensible and latent heat fluxes are 
therefore incorrect.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D031222.18
Start DateStart TimeEnd DateEnd Time
12/13/2003150012/15/20030000
Subject:
SGP/EBBR/E15  - Net Radiometer Iced Over During Storm
DataStreams:sgp30ebbrE15.b1
Description:
The net radiometer was covered with ice from a storm.  Net radiation values are incorrect, 
and are sometimes even negative during the daytime.  Sensible and latent heat fluxes are 
therefore incorrect.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D031222.19
Start DateStart TimeEnd DateEnd Time
12/12/2003195512/13/20031940
Subject:
SGP/EBBR/E15  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp30ebbrE15.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040112.1
Start DateStart TimeEnd DateEnd Time
12/25/2003215001/20/20042030
Subject:
SGP/EBBR/E15 - Wind Direction About 130 Degrees Low
DataStreams:sgp30ebbrE15.b1
Description:
The EBBR wind direction sensor developed an approximately -130 degree offset. The pin 
holding the vane to the shaft had fallen out.
Measurements:sgp30ebbrE15.b1:
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040227.1
Start DateStart TimeEnd DateEnd Time
02/26/2004000003/02/20041705
Subject:
SGP/EBBR/E15 - Net Radiometer not level
DataStreams:sgp30ebbrE15.b1
Description:
The EBBR net radiometer at E15 was suspected to be off of level
               because the daily peak net radiation was recorded later than it 
               was recorded by the SIRS.

               Site Ops found the EBBR net radiometer at E15 was significantly 
               off of level (1/2 bubble tipped to the north).  Adjustment of 
               the level improved the comparison of peak time with the 
               co-located SIRS.

               There was no significant effect on the sensible and latent heat 
               fluxes.
Measurements:sgp30ebbrE15.b1:
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D040304.10
Start DateStart TimeEnd DateEnd Time
02/02/2004094502/02/20041820
02/09/2004121502/09/20041430
Subject:
SGP/EBBR/E12  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE12.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D040304.11
Start DateStart TimeEnd DateEnd Time
02/09/2004123502/09/20041405
02/02/2004081002/02/20041930
Subject:
SGP/EBBR/E12  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D040304.12
Start DateStart TimeEnd DateEnd Time
02/09/2004112502/09/20041500
Subject:
SGP/EBBR/E13  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE13.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D040304.13
Start DateStart TimeEnd DateEnd Time
02/09/2004112502/09/20041500
02/02/2004004002/03/20041810
Subject:
SGP/EBBR/E13  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE13.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D040304.14
Start DateStart TimeEnd DateEnd Time
02/09/2004102002/09/20041430
02/04/2004224002/05/20041840
02/01/2004181002/02/20042040
Subject:
SGP/EBBR/E15  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE15.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040507.1
Start DateStart TimeEnd DateEnd Time
04/23/2004213004/27/20041630
Subject:
SGP/EBBR/E15 - Wind Speed Incorrect
DataStreams:sgp30baebbrE15.c1, sgp30ebbrE15.b1
Description:
The cups were broken off of the wind speed sensor by hail on 4/23/04. The cups were 
replaced on 4/27/04.  Wind speed measurements were near zero and incorrect during the indicated 
period.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp30baebbrE15.c1:
  • res_ws
  • wind_s


Back To Table of Contents

DQRID : D040608.6
Start DateStart TimeEnd DateEnd Time
06/05/2004013007/14/20041515
Subject:
SGP/EBBR/E13 - Automatic Exchange Mechanism Failure
DataStreams:sgp30ebbrE13.b1
Description:
The AEM was stuck in the home_15 position or reported near zero
home signals during much of the indicated period.

The Bowen ratio and latent and sensible heat fluxes were incorrect 
when the AEM was not operating properly; the periods of incorrect
data can be determined from the home signal values.

On 7/14/04 the AEM was replaced.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D040615.3
Start DateStart TimeEnd DateEnd Time
02/19/2004221203/10/20042247
Subject:
SGP/EBBR/E12 - Incorrect Times
DataStreams:sgp30ebbrE12.b1, sgp30baebbrE12.c1
Description:
The ntpd server (time adjustment) stopped working on Feb. 19th at 22:12:16 GMT, and the 
clock was corrected by -5600.177269 seconds on March 10th at 22:47 GMT. The recorded times 
for observations are off by amounts ranging from 0 seconds on Feb. 19th to 5600 seconds 
on March 10th.
Measurements:sgp30ebbrE12.b1:
  • Net radiation(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • soil_heat_flow_2
  • energy_storage_change_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • base_time
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)

sgp30baebbrE12.c1:
  • ts5
  • ts4
  • ts3
  • ts2
  • ts1
  • vp_bot
  • hum_top
  • c_shf2
  • c_shf3
  • Heat flux, sensible, aerodynamic(ah)
  • c_shf1
  • ces5
  • ces4
  • ces3
  • ces2
  • ces1
  • tref
  • vp_top
  • home_30
  • time_offset
  • bowen
  • thum_bot
  • thum_top
  • hum_bot
  • res_ws
  • sigma_wd
  • Corrected sensible heat flux(h)
  • Heat flux, latent(e)
  • c_shf5
  • c_shf4
  • base_time
  • Heat flux, latent, aerodynamic(ale)
  • Average soil heat flux(ave_shf)
  • specific humidity(q)
  • Heat flux, sensible, best estimate(hcomb)
  • tair_bot
  • g1
  • g4
  • g5
  • g2
  • g3
  • shf1
  • shf2
  • shf3
  • shf4
  • shf5
  • cs2
  • cs1
  • cs4
  • cs3
  • cs5
  • sm1
  • wind_d
  • sm2
  • tair_top
  • home_15
  • vegetation_height
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • sm5
  • sm3
  • sm4
  • wind_s
  • austar
  • Heat flux, latent, best estimate(ecomb)


Back To Table of Contents

DQRID : D040615.6
Start DateStart TimeEnd DateEnd Time
02/19/2004221203/10/20042247
Subject:
SGP/SWATS/E12 - Time drift
DataStreams:sgpswatsE12.b1
Description:
The time synchronization server stopped working on Feb. 19th at 22:12:16 GMT.  The clock 
was corrected by -5600.177269 seconds on March 10th at 22:47 GMT. The recorded times for 
observations are off by amounts ranging from 0 seconds on Feb. 19th to 5600 seconds on 
March 10th.
Measurements:sgpswatsE12.b1:
  • tref
  • Soil Temperature, West Profile(tsoil_W)
  • Soil Water Potential, West Profile(soilwatpot_W)
  • base_time
  • Soil Water Potential, East Profile(soilwatpot_E)
  • Sensor Temperature Rise, West Profile(trise_W)
  • Volumetric Water Content, West Profile(watcont_W)
  • Volumetric Water Content, East Profile(watcont_E)
  • Soil Temperature, East Profile(tsoil_E)
  • time_offset
  • Sensor Temperature Rise, East Profile(trise_E)


Back To Table of Contents

DQRID : D040915.2
Start DateStart TimeEnd DateEnd Time
08/11/2004023008/11/20041824
Subject:
SGP/EBBR/E13 - Net Radiation Incorrect, Fluxes Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Rain entered the net radiometer through a crack in the upper dome and
settled in the bottom dome.  This caused too large net radiation measurements
during the following daylight hours, until the domes were replaced and dried out the same 
day.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D040915.6
Start DateStart TimeEnd DateEnd Time
09/08/2004120009/15/20041930
Subject:
SGP/EBBR/E13 - AEM Failure, Fluxes Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The AEM failed.  Sensible and latent heat fluxes were incorrect, as well as gradient 
measurements.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D041004.4
Start DateStart TimeEnd DateEnd Time
10/11/2001150009/28/20041509
Subject:
SGP/EBBR/E15 - Soil Moisture Coefficients Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The soil Moisture coefficients used for E15 were incorrect from the time of
installation of the system in program version 8.  On 9 July 02 parameter 4  (an offset 
value) of program step 136 was changed from 9.5264 to the correct value 0.95264 (this error 
had been made by the vendor). The error masked the real problem (wrong soil type) and 
after 9 July 02 resulted in very low soil moisture measurements.  The coefficients used were 
for coarse sand.  On 28 Sep 04 I visited the E15 site and found the soil type a fine 
sandy clay or fine sandy loam.  I changed the coefficients  at 1509 GMT to those for a very 
fine sandy loam; this produced reasonable soil moistures for the soil type.

The old coefficients in parameters 4 through 9 for step 136 of the program were: 0.95264, 
-6.7859, 36.224, -58.619, 25.073, 4.2278

The new coefficients are: 10.241, -27.943, 49.523, -12.648, -52.643, 38.054
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_2
  • energy_storage_change_3
  • energy_storage_change_2
  • soil_moisture_1
  • soil_moisture_4
  • energy_storage_change_5
  • energy_storage_change_4
  • soil_moisture_3


Back To Table of Contents

DQRID : D041222.11
Start DateStart TimeEnd DateEnd Time
10/12/2004163010/12/20041700
Subject:
SGP/EBBR/E12 - 6 Month Checks
DataStreams:sgp30ebbrE12.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D041222.12
Start DateStart TimeEnd DateEnd Time
10/28/2004183010/28/20041900
Subject:
SGP/EBBR/E13 - 6 Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D041222.13
Start DateStart TimeEnd DateEnd Time
10/26/2004163010/26/20041700
Subject:
SGP/EBBR/E15 - 6 Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D041222.2
Start DateStart TimeEnd DateEnd Time
10/12/2004154510/27/20040645
Subject:
SGP/EBBR/E12 - AEM home_15 Incorrect, Flux Measurements not affected
DataStreams:sgp30ebbrE12.b1
Description:
The home_15 measurement was incorrect during much of the stated period.
The AEM was exchanging however, and thus the flux measurements were not affected.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15


Back To Table of Contents

DQRID : D050114.7
Start DateStart TimeEnd DateEnd Time
10/01/1995000006/30/20032330
Subject:
SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9  - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE13.c1, sgp30baebbrE15.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the calculation of bulk 
aerodynamic sensible and latent heat fluxes instead of site specific heights.

This resulted in either under-estimation or over-estimation of the sensible and latent 
heat fluxes.
Measurements:sgp30baebbrE13.c1:
  • austar
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, aerodynamic(ah)
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, sensible, best estimate(hcomb)

sgp30baebbrE15.c1:
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, sensible, best estimate(hcomb)
  • austar
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, aerodynamic(ah)


Back To Table of Contents

DQRID : D050117.8
Start DateStart TimeEnd DateEnd Time
10/04/1995210006/30/20032359
Subject:
SGP/EBBR/E12 - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE12.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the
calculation of bulk aerodynamic sensible and latent heat fluxes instead of
site specific heights.
   
This resulted in either under-estimation or over-estimation of the sensible
and latent heat fluxes.
Measurements:sgp30baebbrE12.c1:
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, sensible, best estimate(hcomb)
  • Heat flux, sensible, aerodynamic(ah)
  • Heat flux, latent, best estimate(ecomb)
  • austar


Back To Table of Contents

DQRID : D050206.10
Start DateStart TimeEnd DateEnd Time
01/11/2005044501/12/20051310
01/05/2005051001/08/20051745
Subject:
SGP/EBBR/E13  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE13.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D050206.11
Start DateStart TimeEnd DateEnd Time
01/04/2005101001/05/20050200
Subject:
SGP/EBBR/E15  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE15.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050206.9
Start DateStart TimeEnd DateEnd Time
01/05/2005073501/08/20051700
Subject:
SGP/EBBR/E12  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE12.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D050207.5
Start DateStart TimeEnd DateEnd Time
01/05/2005093501/08/20051630
Subject:
SGP/EBBR/E12  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050207.6
Start DateStart TimeEnd DateEnd Time
01/05/2005062501/07/20051850
01/11/2005154501/12/20050930
Subject:
SGP/EBBR/E13  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE13.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D050207.7
Start DateStart TimeEnd DateEnd Time
01/04/2005160501/05/20050200
Subject:
SGP/EBBR/E15  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE15.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE15.b1:
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050215.16
Start DateStart TimeEnd DateEnd Time
01/11/2005104001/11/20050755
Subject:
SGP/EBBR/E12  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE12.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D050215.17
Start DateStart TimeEnd DateEnd Time
01/11/2005104001/12/20050410
Subject:
SGP/EBBR/E12  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050215.18
Start DateStart TimeEnd DateEnd Time
01/12/2005003001/12/20051545
Subject:
SGP/EBBR/E15  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE15.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050215.19
Start DateStart TimeEnd DateEnd Time
01/12/2005003001/12/20050930
Subject:
SGP/EBBR/E15  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE15.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE15.b1:
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050304.1
Start DateStart TimeEnd DateEnd Time
02/25/2005043002/25/20051130
Subject:
SGP/EBBR/E12 - Wind Speed and Direction Frozen by Ice Storm
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed and direction sensors were frozen by ice from and ice storm.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050324.1
Start DateStart TimeEnd DateEnd Time
11/08/2004183003/01/20051630
Subject:
SGP/EBBR/E15 - Soil Heat Flows Undermeasured, and Latent and Sensible Heat Fluxes 
Overstimated
DataStreams:sgp30ebbrE15.b1
Description:
Use of the wrong soil type soil moisture coefficients caused soil moisture to be greatly 
undermeasured (a typical wrong value was 4% instead of the correct 17%), soil heat flows 
to be undermeasured, and sensible and latent heat fluxes to be overestimated.

Soil heat flow plate outputs were undermeasured by up to 10%, change of energy storage was 
undermeasured by up to 80% and total soil heat flow was undermeasured by up to 50% as a 
result. This would result in approximately a 5% overestimation of both sensible and 
latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • soil_heat_capacity_1
  • soil_moisture_5
  • energy_storage_change_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • energy_storage_change_3
  • soil_moisture_2
  • soil_moisture_1
  • energy_storage_change_2
  • soil_moisture_4
  • energy_storage_change_5
  • soil_moisture_3
  • energy_storage_change_4


Back To Table of Contents

DQRID : D050503.6
Start DateStart TimeEnd DateEnd Time
07/13/1996000004/19/20052359
Subject:
SGP/SWATS/E12 - Reprocessing Notice (RID 156)
DataStreams:sgpswatsE12.b1
Description:
See below for details of reprocessing that was completed on 20150814.  Original DQR 
category: 5 (Transparent - Does not affect quality).

-----------------------------------------------------------

The dimension "depth" in the netCDF files was incorrectly reported as 8, and has been 
changed. Newer files with the correct smaller depth dimension do not have extra placeholder 
values and thus are smaller in size.
Measurements:sgpswatsE12.b1:
  • depth


Back To Table of Contents

DQRID : D050503.8
Start DateStart TimeEnd DateEnd Time
02/05/1996000004/19/20052359
Subject:
SGP/SWATS/E13 - Reprocessing Notice (RID 156)
DataStreams:sgpswatsE13.b1
Description:
See below for details of reprocessing that was completed on 20150814.  Original DQR 
category: 5 (Transparent - Does not affect quality).

-----------------------------------------------------------

The dimension "depth" in the netCDF files was incorrectly reported as 8, and has been 
changed. Newer files with the correct smaller depth dimension do not have extra placeholder 
values and thus are smaller in size.
Measurements:sgpswatsE13.b1:
  • depth


Back To Table of Contents

DQRID : D050510.3
Start DateStart TimeEnd DateEnd Time
02/11/2005143005/13/20051900
Subject:
SGP/EBBR/E13 - Net Radiometer Tilted Half Degree West
DataStreams:sgp30ebbrE13.b1
Description:
The net radiation daily peak on sunny days occured 1/2 hour after the net radiation peak 
at E2, E9, and the SIRS because the sensor was tipped to the west about 1/2 degree.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D050622.1
Start DateStart TimeEnd DateEnd Time
06/08/2005190007/06/20051630
Subject:
SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect (AEM failure)
DataStreams:sgp30ebbrE13.b1
Description:
The AEM was stuck in the home 30 position most of this period.

Therefore, the sensible and latent heat fluxes are incorrect during most of this period.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D050624.2
Start DateStart TimeEnd DateEnd Time
05/13/2005080005/24/20051700
Subject:
SGP/EBBR/E15 - Net Radiation Too Large - Water in Bottom
DataStreams:sgp30ebbrE15.b1
Description:
Water in the bottom dome of the net radiometer made the measurements incorrectly large.  
Sensible and latent heat fluxes were therefore 
incorrect.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D050624.7
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/31/20052100
Subject:
SGP/EBBR/E13 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE13.b1
Description:
Effective 20050331.2100, the EBBR.E13 CR10 program was revised to improve the quality of 
the primary measurements as follows:

1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow.  
This is applied to the individual soil sets.  Measurements outside the limits are 
rejected and the measurements within the limits are used to calculate the average soil heat flow.

2) Max and min limits are used to determine incorrect values of net radiation, sensible 
heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal.  If AEM 
signal is outside the limits, h and e are set to 999s.  If net radiation is outside the 
limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s.

Virtually no incorrect soil measurement will affect the primary measurements of h and e.

By setting h and e to 999s, it can be easily seen that the primary variables are 
incorrect; no other interpretation is possible.

Prior to 20050331, the improved CR10 program was NOT in effect.  DQRs have been submitted 
for known instances of incorrect soil measurements which affected the quality of the 
primary measurements of h and e.

Note: the DQR begin date is the begin date of the sgp30ebbrE13.b1 data stream.  The 
earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. 
sgp30ebbrE13.a1).
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D050719.10
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/29/20051900
Subject:
SGP/EBBR/E15 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE15.b1
Description:
Effective 20050329.1900, the EBBR.E15 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050329, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE15.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE15.a1).
Measurements:sgp30ebbrE15.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D050719.9
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/29/20051830
Subject:
SGP/EBBR/E12 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE12.b1
Description:
Effective 20050329.1830, the EBBR.E12 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050329, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE12.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE12.a1).
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D051104.2
Start DateStart TimeEnd DateEnd Time
10/01/2005203010/12/20052130
Subject:
SGP/EBBR/E13 - Fluxes Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The AEM has not been reaching the home_30 position fully a few times a day on most days, 
resulting in zero home_30 measurements.

The sensible and latent heat fluxes are incorrect when the home_30 measurement is near 
zero.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D051104.3
Start DateStart TimeEnd DateEnd Time
08/17/2005223010/05/20051600
Subject:
SGP/EBBR/E13 - Loose connections
DataStreams:sgp30ebbrE13.b1
Description:
The tair_bot spiked around midday, as if it is temperature related, and may have indicated 
a loose connection.

The sensible and latyent heat fluxes and Bowen ratio were incorrect when this condition 
occurred.
Measurements:sgp30ebbrE13.b1:
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D051106.23
Start DateStart TimeEnd DateEnd Time
03/01/2005180003/29/20051830
Subject:
SGP/EBBR/E12 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D051106.24
Start DateStart TimeEnd DateEnd Time
03/03/2005213003/31/20052100
Subject:
SGP/EBBR/E13 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D051106.25
Start DateStart TimeEnd DateEnd Time
03/01/2005180003/29/20051900
Subject:
SGP/EBBR/E15 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE15.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D051106.9
Start DateStart TimeEnd DateEnd Time
07/15/2005213007/19/20051700
Subject:
SGP/EBBR/E15 - Soil Set #5 Temperature, Moisture, and Heat Flow Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Rodents chewed the cables on all three soil set #5 sensors, making the measurements 
incorrect.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_5
  • Soil temperature mean 5(soil_temp_5)
  • soil_heat_capacity_5
  • soil_moisture_5
  • soil_heat_flow_5
  • energy_storage_change_5


Back To Table of Contents

DQRID : D051111.10
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E12 - metadata corrections
DataStreams:sgp30ebbrE12.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E12 data collected by ARM back to the installation of the 
instrument in August 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.  

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil type
4) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE12.b1:
  • base_time


Back To Table of Contents

DQRID : D051111.11
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E13 - metadata corrections
DataStreams:sgp30ebbrE13.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E13 data collected by ARM back to the installation of the 
instrument in September 1992.  Please see the current metadata for correct information.  
These changes do not affect data values or quality.

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for systems
3) Correction of soil type
4) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE13.b1:
  • base_time


Back To Table of Contents

DQRID : D051111.12
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E15 - metadata corrections
DataStreams:sgp30ebbrE15.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E15 data collected by ARM back to the installation of the 
instrument in September 1992. Please see the current metadata for correct information.  
These changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil type
4) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE15.b1:
  • base_time


Back To Table of Contents

DQRID : D051215.3
Start DateStart TimeEnd DateEnd Time
10/30/2005000011/08/20051815
Subject:
SGP/EBBR/E15 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect.
DataStreams:sgp30ebbrE15.b1
Description:
The top dome of the net radiometer was broken, resulting in net radiations that were too 
small, and thus sensible and latent heat fluxes that were too small.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D060111.10
Start DateStart TimeEnd DateEnd Time
01/10/2006133001/17/20061730
Subject:
SGP/EBBR/E15 - Incorrect Sensible and Latent Heat Fluxes
DataStreams:sgp30ebbrE15.b1
Description:
Incorrect gradient measurements and sensible and latent heat fluxes resulted from the AEM 
not exchanging.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D060111.11
Start DateStart TimeEnd DateEnd Time
11/27/2005000012/18/20051200
Subject:
SGP/EBBR/E15 - Reprocess: Sensible and Latent Heat Fluxes, Soil Set #2 Sometimes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Spikes in soil set #2 sometimes caused sensible and latent heat fluxes to be incorrect.  

There is no electronic connection between the soil set #2 sensors, so it is suspected that 
there was a problem in the soil set #2 cable bundle. A power outage ensued, after which 
the soil set #2 problem did not re-occur.
Measurements:sgp30ebbrE15.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 2(soil_temp_2)
  • surface_soil_heat_flux_2
  • soil_heat_capacity_2
  • soil_heat_flow_2
  • soil_moisture_2
  • Sensible heat flux(sensible_heat_flux)
  • energy_storage_change_2


Back To Table of Contents

DQRID : D060111.5
Start DateStart TimeEnd DateEnd Time
12/27/2005173001/02/20062330
Subject:
SGP/EBBR/E12 - Sensible and Latent Heat Fluxes Incorrect at Times
DataStreams:sgp30ebbrE12.b1
Description:
Large spikes in soil temperature #2 are causing the soil heat storage
term to blow up, and thus the average soil heat flow, sensible heat flux, 
and latent heat flux to be incorrect at times.
Measurements:sgp30ebbrE12.b1:
  • energy_storage_change_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D060111.8
Start DateStart TimeEnd DateEnd Time
12/08/2005110012/08/20051300
Subject:
SGP/EBBR/E12 - Multiplexer failure
DataStreams:sgp30ebbrE12.b1
Description:
Sensible and latent heat fluxes are incorrect during a period when multiplexer #2 
experienced a failure.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_moisture_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • soil_heat_flow_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_moisture_3
  • soil_moisture_2
  • surface_soil_heat_flux_3
  • soil_heat_flow_1
  • soil_heat_flow_2
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D060111.9
Start DateStart TimeEnd DateEnd Time
12/18/2005090012/20/20051600
12/21/2005050012/21/20051830
Subject:
SGP/EBBR/E13 - Wind Speed Sensor Frozen
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was frozen to a stopped posiiton; wind speed data is incorrect.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D060501.11
Start DateStart TimeEnd DateEnd Time
04/15/2006230004/25/20061700
Subject:
SGP/EBBR/E12 - Fluxes and Gradient Measurements Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The AEM hung in one position; therefore the fluxes and gradient measurements were 
incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D060501.12
Start DateStart TimeEnd DateEnd Time
01/06/2006173001/09/20060730
02/17/2006200502/20/20061030
01/10/2006133001/10/20061930
Subject:
SGP/EBBR/E13 - Missing Data
DataStreams:sgp30ebbrE13.b1
Description:
The Data was missing during these three periods for various reasons.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D060501.13
Start DateStart TimeEnd DateEnd Time
01/22/2006233001/26/20062040
Subject:
SGP/EBBR/E13 - Flux and Gradient Measurements Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The AEM hung in one position; flux and gradient measurements were therefore incorrect.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060501.14
Start DateStart TimeEnd DateEnd Time
04/02/2006033004/05/20061435
Subject:
SGP/EBBR/E13 - Net Radiation and Fluxes Suspect
DataStreams:sgp30ebbrE13.b1
Description:
The net radiometer had water in it, making the net radiation and flux measurements 
suspect; the latter do not appear to be incorrect, but should be considered as suspect anyway.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060501.15
Start DateStart TimeEnd DateEnd Time
02/22/2006130002/22/20061530
Subject:
SGP/EBBR/E15 - Wind Speed Sensor Frozen Stopped
DataStreams:sgp30ebbrE15.b1
Description:
Freezing rain froze the wind speed sensor to a stopped condition during the period.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D060622.1
Start DateStart TimeEnd DateEnd Time
04/23/2006230004/23/20062300
06/03/2006190006/04/20062330
Subject:
SGP/EBBR/E13 - Left Air Temperature Incorrect - Fluxes Affected
DataStreams:sgp30ebbrE13.b1
Description:
The left air temperature was incorrect, thus the Bowen ratio and sensible and latent heat 
fluxes were incorrect also.
Measurements:sgp30ebbrE13.b1:
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060622.2
Start DateStart TimeEnd DateEnd Time
04/30/2006210005/01/20061530
06/14/2006203006/15/20061430
06/05/2006233006/06/20061600
Subject:
SGP/EBBR/E13 - Fluxes Incorrect, AEM Problems
DataStreams:sgp30ebbrE13.b1
Description:
The AEM did not function properly, thus sensible and latent heat fluxes were incorrect.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060802.1
Start DateStart TimeEnd DateEnd Time
07/12/2006000008/15/20061800
Subject:
SGP/SWATS/E12 - Incorrect soil moisture
DataStreams:sgpswatsE12.b1
Description:
Temperature rise values were way to high (~40 deg C).  Water potential is calculated from 
a rise (and subsequent drop) in temperature in the sensor that is normally ~1-5 degrees 
C.  When the temperature rise is too high, the soil moisture data is dubious at best and 
unusable at worst.  Since this "out-of-bounds" t_rise is so high, the soil moisture data 
are practically unusable.

Soil temperature measurements were not affected.
Measurements:sgpswatsE12.b1:
  • Soil Water Potential, West Profile(soilwatpot_W)
  • Soil Water Potential, East Profile(soilwatpot_E)
  • Sensor Temperature Rise, West Profile(trise_W)
  • Volumetric Water Content, West Profile(watcont_W)
  • Volumetric Water Content, East Profile(watcont_E)
  • Sensor Temperature Rise, East Profile(trise_E)


Back To Table of Contents

DQRID : D060818.10
Start DateStart TimeEnd DateEnd Time
07/01/2006170007/06/20062200
Subject:
SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect When Pressure Offscale
DataStreams:sgp30ebbrE13.b1
Description:
There were several half hours during this period when the pressure went offscale or at 
least to a high value, causing the sensible and latent heat fluxes to be incorrect.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060921.3
Start DateStart TimeEnd DateEnd Time
08/21/2006120008/29/20061630
Subject:
SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Rain entered into the net radiometer through a broken top dome.  Most of the net radiation 
values during the period are much too large, thus sensible and latent fluxes are also 
too large.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D060921.4
Start DateStart TimeEnd DateEnd Time
09/01/2006013009/12/20061630
Subject:
SGP/EBBR/E12 - Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
During much of this period soil temperature #1 was offscale or erratic.
Sensible and latent heat fluxes were not ususally affected.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_1
  • energy_storage_change_1
  • Soil temperature mean 1(soil_temp_1)
  • surface_soil_heat_flux_1


Back To Table of Contents

DQRID : D060921.5
Start DateStart TimeEnd DateEnd Time
08/31/2006203009/01/20061900
08/05/2006173008/10/20061730
08/23/2006170008/25/20061700
Subject:
SGP/EBBR/E13 - Soil Heat Flow #3 Large Negative
DataStreams:sgp30ebbrE13.b1
Description:
During this period Soil Heat Flow #3 was sometimes incorrect (large negative); during 
those times, sensible and latent heat fluxes and average soil heat flux were sometimes (but 
not always incorrect).
Measurements:sgp30ebbrE13.b1:
  • soil_heat_flow_3
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060921.6
Start DateStart TimeEnd DateEnd Time
08/24/2006153008/24/20062000
08/22/2006163008/22/20061830
08/29/2006083008/29/20061200
Subject:
SGP/EBBR/E13 - Pressure and Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
During spikes in pressure upwards or downwards the sensible and latent heat fluxes were 
incorrect.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060921.7
Start DateStart TimeEnd DateEnd Time
08/28/2006003008/28/20060730
Subject:
SGP/EBBR/E13 - Most Measurements Incorrect When Battery Voltage Too low
DataStreams:sgp30ebbrE13.b1
Description:
Most measurements were incorrect during this period because the battery voltage was below 
10.5 volts.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D061114.6
Start DateStart TimeEnd DateEnd Time
10/17/2006070010/23/20061615
Subject:
SGP/EBBR/E13 - Battery failure
DataStreams:sgp30ebbrE13.b1
Description:
Data was missing entirely on parts of 10/22 and 10/23.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • temp_trh_top
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • energy_storage_change_2
  • soil_moisture_4
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D070917.1
Start DateStart TimeEnd DateEnd Time
09/02/2006040009/14/20061900
Subject:
SGP/EBBR/E13 - Radiometer dome broken
DataStreams:sgp30ebbrE13.b1
Description:
The top net radiometer dome was broken, yielding net radiation, sensible heat flux and 
latent heat flux that were too low.

The BEFLUX (SIRS) net radiation can be used as a replacement for the EBBR net radiation.

To correct the sensible and latent heat fluxes, determine the ratio of SIRS net radiation 
to EBBR net radiation for each daylight half hour and multiply that ratio times H and LE 
to obtain approximate corrected flux values.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D071026.2
Start DateStart TimeEnd DateEnd Time
08/28/2007210011/06/20071700
Subject:
SGP/SWATS/E12 - Reprocess: Incorrect calibrations
DataStreams:sgpswatsE12.b1
Description:
Incorrect data configuration program was loaded on logger resulting in incorrect 
coefficients applied.  Data will be reprocessed with correct coefficients.
Measurements:sgpswatsE12.b1:
  • tref
  • Soil Temperature, West Profile(tsoil_W)
  • Soil Water Potential, West Profile(soilwatpot_W)
  • Soil Water Potential, East Profile(soilwatpot_E)
  • Sensor Temperature Rise, West Profile(trise_W)
  • Volumetric Water Content, West Profile(watcont_W)
  • Volumetric Water Content, East Profile(watcont_E)
  • Soil Temperature, East Profile(tsoil_E)
  • Sensor Temperature Rise, East Profile(trise_E)


Back To Table of Contents

DQRID : D080318.1
Start DateStart TimeEnd DateEnd Time
03/18/2008100003/27/20081930
Subject:
SGP/EBBR/E13 - Wind direction failure
DataStreams:sgp30ebbrE13.b1
Description:
The EBBR wind direction was stuck at 135 degrees; this reading indicates a failure of the 
sensor electronics.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D080616.4
Start DateStart TimeEnd DateEnd Time
06/11/2008150006/20/20081500
Subject:
SGP/EBBR/E15 - Water in dome
DataStreams:sgp30ebbrE15.b1
Description:
There was water in the bottom dome of the net radiometer.

Net radiation, and sensible and latent heat fluxes were 
incorrect during the period.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D080616.5
Start DateStart TimeEnd DateEnd Time
05/01/2008003006/15/20081500
Subject:
SGP/EBBR/E15 - Soil Heat Flow #4 Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Soil heat flux #4 produced too large a soil heat flow at times, resulting in it exceeding 
the qc check limit and causing sensible and latent heat fluxes to be incorrect.
Measurements:sgp30ebbrE15.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_4
  • corr_soil_heat_flow_4
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_flow_4


Back To Table of Contents

DQRID : D081210.12
Start DateStart TimeEnd DateEnd Time
01/06/2006230003/01/20161800
Subject:
SGP/SWATS/E15 - Sensor failure, 5cm E
DataStreams:sgpswatsE15.b1
Description:
The 5 cm sensor installed in the east profile failed on 01/06/2006 at 23:00 GMT.
Measurements:sgpswatsE15.b1:
  • Soil water potential, east profile(soilwatpot_e)
  • Soil temperature, east profile(tsoil_e)
  • Sensor temperature rise, east profile(trise_e)
  • Volumetric water content, east profile(watcont_e)


Back To Table of Contents

DQRID : D081210.13
Start DateStart TimeEnd DateEnd Time
05/07/2008200011/04/20082000
Subject:
SGP/SWATS/E15 - Incorrect soil moisture
DataStreams:sgpswatsE15.b1
Description:
At 20:00 GMT on 05/07/08, temperature rise data from ALL sensors on both profiles began 
reporting values of temperature change near 0 C. These incorrect values of temperature rise 
result in incorrect soil moisture data for all sensors. 

Soil temperature data are unaffected.
Measurements:sgpswatsE15.b1:
  • Soil Water Potential, West Profile(soilwatpot_W)
  • Soil Water Potential, East Profile(soilwatpot_E)
  • Volumetric Water Content, East Profile(watcont_E)
  • Sensor Temperature Rise, East Profile(trise_E)
  • Volumetric Water Content, West Profile(watcont_W)
  • Sensor Temperature Rise, West Profile(trise_W)


Back To Table of Contents

DQRID : D090313.12
Start DateStart TimeEnd DateEnd Time
01/27/2009024501/28/20092005
Subject:
SGP/EBBR/E12 - Wind Speed Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed sensor was stopped by freezing rain.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D090313.13
Start DateStart TimeEnd DateEnd Time
01/26/2009201501/28/20092000
Subject:
SGP/EBBR/E13 - Wind Speed Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was stopped by freezing rain.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D090313.14
Start DateStart TimeEnd DateEnd Time
01/26/2009183001/28/20091935
Subject:
SGP/EBBR/E15 - Wind Speed Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D090313.2
Start DateStart TimeEnd DateEnd Time
01/27/2009193002/25/20091830
Subject:
SGP/EBBR/E15 - Soil Moisture and Soil Temp #1 Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Soil Moisture #1 and Soil Temperature #1 were incorrect during this period.

This situation did not affect the sensible and latent heat fluxes (EBBR programming used 
only the 4 good soil measurements to determine soil surface heat flux).
Measurements:sgp30ebbrE15.b1:
  • corr_soil_heat_flow_1
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_1
  • energy_storage_change_1
  • surface_soil_heat_flux_1
  • soil_moisture_1


Back To Table of Contents

DQRID : D100223.1
Start DateStart TimeEnd DateEnd Time
02/21/2010230002/22/20101730
Subject:
SGP/EBBR/E12 - Wind Speed Sensor Frozen Stopped by Icing
DataStreams:sgp30ebbrE12.b1
Description:
Icing stopped the wind speed sensor cups and resulted in the measurement of wind speed 
being equivalent to the sensor offset.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D100510.1
Start DateStart TimeEnd DateEnd Time
03/19/2010193005/05/20101745
Subject:
SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Low
(Net Radiation too low)
DataStreams:sgp30ebbrE15.b1
Description:
Sensible and Latent Heat Fluxes were measured as being low because of damage to the net 
radiometer.

The Sensible and Latent Heat fluxes can be approximated by taking the ratio of the daytime 
SIRS net radiation to EBBR net radiation, and then multiplying the Sensible and Latent 
Heat Fluxes by that ratio.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D100720.2
Start DateStart TimeEnd DateEnd Time
05/03/2010000006/08/20101800
Subject:
SGP/EBBR/E12 - Intermittent data loss
DataStreams:sgp30ebbrE12.b1
Description:
The datalogger at E12 EBBR reset it's time to Dec 3, 1999 on a periodic basis.  This 
occurred on 5/3, 5/15, 5/17, 5/18, 5/27, 6/5 and 6/6 of 2010. Each time this occurred we lost 
1-2 hours of data.

The datalogger was apparently at fault.  The problem has not re-occurred since the 
datalogger was replaced on 6/8/2010.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • North latitude(lat)
  • East longitude(lon)
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • time
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Altitude above mean sea level(alt)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D100720.3
Start DateStart TimeEnd DateEnd Time
06/10/2010120006/23/20101630
Subject:
SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Other Measurements Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The power supply leads for the combined temperature probe shorted somehow, resulting in 
several measurements from the probe and for the multiplexer that it was connected to, to be 
incorrect.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_3
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_4
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • soil_moisture_1
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • soil_moisture_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_moisture_4
  • soil_moisture_3
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_moisture_2
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_heat_capacity_5
  • energy_storage_change_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D100727.5
Start DateStart TimeEnd DateEnd Time
07/06/2010193007/21/20101400
Subject:
SGP/EBBR/E13 - Incorrect Sensible and Latent Heat Fluxes
DataStreams:sgp30ebbrE13.b1
Description:
The multiplexer to which the air temperatures were connected experienced a problem, 
resulting in incorrect sensible and latent heat fluxes at times.
Measurements:sgp30ebbrE13.b1:
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D101004.1
Start DateStart TimeEnd DateEnd Time
09/01/2010120009/29/20101600
Subject:
SGP/EBBR/E12 - Net radiation too high
DataStreams:sgp30ebbrE12.b1
Description:
Net radiation was too high, resulting in overestimated sensible and latent heat fluxes. 

Net rad domes replaced.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D101004.2
Start DateStart TimeEnd DateEnd Time
07/21/2010133010/01/20102000
Subject:
SGP/EBBR/E13 - Net Radiation Too Large
DataStreams:sgp30ebbrE13.b1
Description:
The EBBR Net Radiation (Rn) values maintained a ~200 Wm^-2 reading because of poor cable 
lead connections.  Sensible and latent heat fluxes were therefore overestimated.

Sensible (H) and latent heat (LE) fluxes can be estimated in the following way:

H (new) = H/[1 + (EBBR Rn - SIRS net radiation)/SIRS net radiation]

LE (new) = LE/[1 + (EBBR Rn - SIRS net radiation)/SIRS net radiation]
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D101007.1
Start DateStart TimeEnd DateEnd Time
08/24/2010163010/05/20101600
Subject:
SGP/EBBR/E15 - Sensible and Latent Heat Flux Suspect - Soil Heat Flow 5 Problem
DataStreams:sgp30ebbrE15.b1
Description:
Soil Heat Flow sensor 5 was offscale at times, causing sensible and latent heat fluxes to 
be incorrect during those times.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D110629.1
Start DateStart TimeEnd DateEnd Time
06/12/2011060006/23/20112000
Subject:
SGP/SWATS/E13 - Lightning damage
DataStreams:sgpswatsE13.b1
Description:
After a lightning strike near the CF, the SWATS trise values were reporting near zero. The 
current channel in the CE8 module failed, so the wire was moved to the next channel and 
trise values returned to normal.

There are no soil moisture data available during this time period.
Measurements:sgpswatsE13.b1:
  • Soil Water Potential, West Profile(soilwatpot_W)
  • Sensor Temperature Rise, West Profile(trise_W)
  • Sensor Temperature Rise, East Profile(trise_E)
  • Volumetric Water Content, West Profile(watcont_W)
  • Volumetric Water Content, East Profile(watcont_E)
  • Soil Water Potential, East Profile(soilwatpot_E)


Back To Table of Contents

DQRID : D110707.1
Start DateStart TimeEnd DateEnd Time
12/19/2004130712/23/20042108
03/14/2002230703/16/20020007
10/31/2007170711/06/20072045
07/02/2006120707/05/20061733
06/18/2011040706/27/20111307
01/28/2002230702/10/20021707
08/18/1997090709/09/19971605
10/10/2007160710/23/20071658
05/08/2010090705/13/20101907
09/16/2010010709/21/20101516
05/23/2011210706/14/20111527
Subject:
SGP/SWATS/E15 - Missing data
DataStreams:sgpswatsE15.b1
Description:
Data are missing and unrecoverable.
Measurements:sgpswatsE15.b1:
  • serial_numbers_E
  • Soil Water Potential, East Profile(soilwatpot_E)
  • time_offset
  • Volumetric Water Content, East Profile(watcont_E)
  • Sensor Temperature Rise, East Profile(trise_E)
  • depth
  • Soil Temperature, West Profile(tsoil_W)
  • North latitude(lat)
  • base_time
  • Altitude above mean sea level(alt)
  • tref
  • Soil Water Potential, West Profile(soilwatpot_W)
  • serial_numbers_W
  • East longitude(lon)
  • Soil Temperature, East Profile(tsoil_E)
  • Volumetric Water Content, West Profile(watcont_W)
  • Sensor Temperature Rise, West Profile(trise_W)


Back To Table of Contents

DQRID : D110721.1
Start DateStart TimeEnd DateEnd Time
06/30/2011150007/15/20111400
Subject:
SGP/EBBR/E13 - Soil temperature #3 offscale
DataStreams:sgp30ebbrE13.b1
Description:
Soil Temp Sensor 3 data were missing or offscale due to a bad connection. 

H and LE were not normally affected, as the EBBR program "kicked" out the incorrect 
temperature measurements before calculating H and LE.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • surface_soil_heat_flux_3
  • soil_heat_capacity_3
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D110830.1
Start DateStart TimeEnd DateEnd Time
06/29/2011153008/03/20111500
Subject:
SGP/EBBR/E12 - Loose connection (SHF #4)
DataStreams:sgp30ebbrE12.b1
Description:
Soil Heat Flow #4 was sometimes offscale due to a bad connection.  Sensible and latent 
heat fluxes also affected at times.
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D120128.2
Start DateStart TimeEnd DateEnd Time
08/28/2011230001/24/20121730
Subject:
SGP/EBBR/E15 - Soil heat flow #1 failure
DataStreams:sgp30ebbrE15.b1
Description:
Soil heat flow 1 sensor wires chewed by rodents. Values less than the accepted minimum.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D120305.1
Start DateStart TimeEnd DateEnd Time
11/28/2011140002/06/20121830
Subject:
SGP/EBBR/E15 - Soil heat flow #5 failure
DataStreams:sgp30ebbrE15.b1
Description:
Soil_heat_flow_5 sensor failed at times, resulting in sensible and latent heat fluxes 
being incorrect at times. Sensor was replaced 2/6/2012.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D120307.1
Start DateStart TimeEnd DateEnd Time
01/19/2012170002/12/20121630
Subject:
SGP/EBBR/E12 - Soil heat flux #4 intermittently incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil heat flux #4 measurements were sometimes incorrect and sometimes affected the 
sensible and latent heat flux calculations.
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D120507.4
Start DateStart TimeEnd DateEnd Time
03/06/2012000005/02/20121730
Subject:
SGP/EBBR/E15 - Sensible and Latent heat fluxes incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Soil Heat Flow sensor 5 was incorrect at times and just "noisy" at other times. Therefore 
Sensible and Latent heat fluxes were often incorrect.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • soil_heat_flow_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D120507.5
Start DateStart TimeEnd DateEnd Time
03/05/2012000004/25/20121630
Subject:
SGP/EBBR/E12 - Sensible and Latent heat fluxes incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The air and T/RH measurements were incorrect at times.  Loose RH/temp connection was 
reseated.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D121107.1
Start DateStart TimeEnd DateEnd Time
08/24/2012190010/31/20121930
Subject:
SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Soil heat flow 1 did not report correctly at times, resulting in incorrect sensible and 
latent heat fluxes at times.
Measurements:sgp30ebbrE15.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130110.4
Start DateStart TimeEnd DateEnd Time
12/28/2012173001/07/20131830
12/24/2012143012/26/20121900
Subject:
SGP/EBBR/E15 - Sensible and latent heat fluxes incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The AEM stuck in between levels during these two periods.

Therefore, sensible and latent heat fluxes were incorrect during these times.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130110.5
Start DateStart TimeEnd DateEnd Time
08/26/2012000012/12/20121900
Subject:
SGP/EBBR/E12 - Sensible and latent heat fluxes intermittently incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil temperature 1 and soil moisture 1 fluctuated unnaturally, spiking to large values at 
times. 

Sensible and latent heat flux measurements were therefore sometimes incorrect.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_1
  • corr_soil_heat_flow_1
  • energy_storage_change_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130201.4
Start DateStart TimeEnd DateEnd Time
12/26/2012163001/28/20131830
Subject:
SGP/EBBR/E12 - Net rad too high
DataStreams:sgp30ebbrE12.b1
Description:
The net radiometer measurements were too large and therefore resulted in incorrect 
sensible and latent heat flux measurements.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D130410.10
Start DateStart TimeEnd DateEnd Time
02/13/2013080002/20/20132130
Subject:
SGP/EBBR/E15 - AEM failure
DataStreams:sgp30ebbrE15.b1
Description:
AEM failure; sensible and latent heat fluxes are incorrect.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130410.4
Start DateStart TimeEnd DateEnd Time
01/23/2013220001/24/20131713
02/21/2013040002/28/20131630
01/31/2013160001/31/20131800
01/30/2013140001/30/20131800
Subject:
SGP/EBBR/E12 - AEM failure
DataStreams:sgp30ebbrE12.b1
Description:
An AEM failure caused incorrect sensible and latent heat fluxes.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130410.5
Start DateStart TimeEnd DateEnd Time
11/21/2012133012/06/20121530
Subject:
SGP/EBBR/E13 - Soil temp 5 offscale
DataStreams:sgp30ebbrE13.b1
Description:
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Soil temperature mean 5(soil_temp_5)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130410.6
Start DateStart TimeEnd DateEnd Time
01/13/2013230001/17/20131630
Subject:
SGP/EBBR/E13  - Soil temp 4 failure
DataStreams:sgp30ebbrE13.b1
Description:
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130410.7
Start DateStart TimeEnd DateEnd Time
02/20/2013160002/28/20132030
Subject:
SGP/EBBR/E13 - AEM failure
DataStreams:sgp30ebbrE13.b1
Description:
The AEM mechanism failed, causing sensible and latent heat fluxes to be incorrect.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130410.9
Start DateStart TimeEnd DateEnd Time
12/09/2012150012/11/20121730
02/25/2013233003/02/20131800
Subject:
SGP/EBBR/E15 - Missing data
DataStreams:sgp30ebbrE15.b1
Description:
Data are missing and unrecoverable.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • time
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D130507.2
Start DateStart TimeEnd DateEnd Time
04/05/2013000004/11/20131730
Subject:
SGP/EBBR/E12 - Soil temp 1 erratic
DataStreams:sgp30ebbrE12.b1
Description:
Soil temperature sensor 1 produced erratic data at times; sensible and latent heat fluxes 
were incorrect at these times.
Measurements:sgp30ebbrE12.b1:
  • energy_storage_change_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130621.1
Start DateStart TimeEnd DateEnd Time
05/28/2013080006/19/20131600
Subject:
SGP/EBBR/E13 - Incorrect sensible and latent heat fluxes
DataStreams:sgp30ebbrE13.b1
Description:
AEM Home Signal was less than the valid min, resulting in incorrect latent and sensible 
heat fluxes.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130718.3
Start DateStart TimeEnd DateEnd Time
04/10/2013063007/09/20131800
Subject:
SGP/EBBR/E15 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The AEM did not work. Sensible and latent heat fluxes are incorrect for this period.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130930.1
Start DateStart TimeEnd DateEnd Time
07/14/2013210008/23/20131600
Subject:
SGP/SWATS/E15 - Noisy East 25cm sensor data
DataStreams:sgpswatsE15.b1
Description:
The trise variable for the East 25cm sensor was sporadic beginning July 14. The values 
were spiking upward (dry) especially during rain events. 

After re-seating the wires the values returned to normal, less noisy with no spikes during 
rain events.
Measurements:sgpswatsE15.b1:
  • fwi_e
  • Soil water potential, east profile(soilwatpot_e)
  • Reference sensor temperature rise, east profile(trise_ref_e)
  • Sensor temperature rise, east profile(trise_e)
  • Volumetric water content, east profile(watcont_e)


Back To Table of Contents

DQRID : D131114.3
Start DateStart TimeEnd DateEnd Time
10/26/2013160011/12/20131900
Subject:
SGP/EBBR/E15 - Soil temp 3 failure
DataStreams:sgp30ebbrE15.b1
Description:
Soil temperature 3 data were incorrect, resulting in sensible and latent heat fluxes 
sometimes being incorrectly calculated.
Measurements:sgp30ebbrE15.b1:
  • surface_soil_heat_flux_3
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • Soil temperature mean 3(soil_temp_3)
  • energy_storage_change_3
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D131216.3
Start DateStart TimeEnd DateEnd Time
10/14/2013140001/02/20141730
Subject:
SGP/EBBR/E12 - Multiplexer/datalogger problems
DataStreams:sgp30ebbrE12.b1
Description:
The AEM did not operate correctly at times. Sensible and latent heat fluxes were sometimes 
affected.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D140117.7
Start DateStart TimeEnd DateEnd Time
09/30/2013153012/10/20131800
Subject:
SGP/EBBR/E12 - Intermittent spikes in soil temp 1
DataStreams:sgp30ebbrE12.b1
Description:
Soil Temperature 1 spikes upward at times, sometimes affecting the sensible and latent 
heat fluxes.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • energy_storage_change_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D140318.5
Start DateStart TimeEnd DateEnd Time
05/30/2013171506/06/20131330
Subject:
SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Too Large, Net Radiation Too Large
DataStreams:sgp30ebbrE13.b1
Description:
The net radiometer top dome broke and water entered the dome. The water settled in the 
bottom dome and caused net radiation measurements to be too large.

Sensible and latent heat fluxes are therefore calculated to be too large.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D150309.5
Start DateStart TimeEnd DateEnd Time
02/29/2008163003/04/20101600
Subject:
SGP/EBBR/E13 - Reprocess: Incorrect data logger program
DataStreams:sgp30ebbrE13.b1
Description:
The soil moisture data is incorrect. It's likely that the proper procedure was not 
followed during a preventative maintenance visit and an older or an incorrect EF data logger 
program was installed, greatly reducing the soil moisture values.
Measurements:sgp30ebbrE13.b1:
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_3
  • soil_moisture_4


Back To Table of Contents

DQRID : D930428.2
Start DateStart TimeEnd DateEnd Time
07/13/1993120107/13/19931202
Subject:
SGP/EBBR/E13 - incorrect home signal
DataStreams:sgp30ebbrE13.b1
Description:
EDITOR'S NOTE:  This DQR refers to data collected by the EBBR at E13 prior
to the begin date of regular ARM data.  At that time, the data streams which
contain the EBBR.E13 data were named 
      Dsgp15ebbr1.a0
      Dsgp30ebbr1.a1
      Dsgp5ebbr1.a0
These data are not readily available from the ARM archive, but can be
made available by special request.  The actual time range of the problem
described here is 921230.0000-930423.1200.



EBBR1, Central Facility reported incorrect home value signals from 30
December 1992 through 23 April 1993.  The home signals are used in the
calculation of fluxes by the CR10 data logger.  The fluxes for this period
are thus invalid as reported and must be recalculated from the archived 15
minute data.  The proper home signals are less than 35 for 30 minute home
signal and greater than 35 for 15 minute home signal.  Home signals were
the same value for 15 minute and 30 minute during the period of interest,
although they were not a constant value.  The chronology of the situation
is reported below.  On 7 April 1993 I noticed the problem in the A0 data.

On 30 December 1992, the automatic exchange mechanism (AEM) of the Central
Facility EBBR froze up with ice and stopped working (surmised from looking
at the EBBR1 data).  This caused a fuse to blow and stop the mechanism from
operating.  However, one channel of the CR10 data logger was apparently damaged
in the process.  The condition of the AEM only, was noticed on 4 January 1993
by site operations personnel.  The blown fuse was replaced, which started
the AEM working; but AEM home signal values between 30 Dec and 04 Jan were
around zero.  Home values remained around zero until at least January 8, 1993.
I have a gap in data archived at ANL between 8 and 15 January 1993, during
which I do not know quite what was happening.  On 11 January 1993 site
operations personnel found that the EBBR1 battery was run down and the EBBR
thus was not working.  A new battery was installed.  On 15 January the home
values were about 34.  I am assuming that they became 34 upon installation
of the new battery on 11 January.  Until at least 15 January the home signals
stayed around 34.  After that period the home signals became greater than
35 and generally were around 36.  Only occasionally (a few hours here and
there)were the home signals just above or below 35 to produce the proper
flux outputs.  On 23 April 1993, at my direction (and after a week of tests
on other parts of the system), the CR10 data logger was replaced.  This solved
the problem.  In fact, previous to this I had suggested reloading the software
into the previous CR10, but the CR10 would not accept it; as soon as the
machine was deactivated before that procedure it stopped working altogether.
I find it amazing that it worked at all, although all data other than the home
signals, and the calculated quantities dependent on them looked perfectly
acceptable during the period of interest; there is no evidence that the
CR10 was malfunctioning in other areas.

The road to restoring the 30 Dec to 23 April data would be a rocky one, as
each 15 minute data period would have to be examined to determine the
proper position of the sensors on the AEM.  However, it is possible to
reconstruct most of the 30 minute calculated values from the 15 minute data.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D930503.2
Start DateStart TimeEnd DateEnd Time
07/13/1993120107/13/19931202
Subject:
SGP/EBBR/E13 - incorrect meteorological observations
DataStreams:sgp30ebbrE13.b1
Description:
EDITOR'S NOTE:  This DQR refers ti data collected by the EBBR at E13 prior
to the begin date of regular ARM data.  At that time, the data streams which
contain the EBBR.E13 data were named
      Dsgp15ebbr1.a0
      Dsgp30ebbr1.a1
      Dsgp5ebbr1.a0
These data are not readily available from the ARM archive, but can be 
made available by special request.  The actual time range of the problem
described here is 930417.1200-930422.1730.


Beginning at 1200 UTC on 17 April 1993, EBBR1, Central Facility, outputs
ramped to extreme values, some positive, some negative.  These outputs ended
their ramping approximately 3 hours later.  Comparison with SMOS data
indicate that no time averaged outputs from EBBR1 were consistent with the
SMOS after 1200 UTC.

It appears that the averaging instruction in the CR10 data logger had been
corrupted.  On 22 April site operations, at my request, tried to reenter
the software; this attempt was completely unsuccessful, indicating that the
CR10 probably had other problems as well.  EBBR1 was offline from 1730 UTC
on 22 April until 1400 UTC on 23 April, when a new CR10 was installed and the
software downloaded successfully.

Since a SDS utility for extracting real time data from the CF SMOS had not been
established, EBBR1 was being used for weather observations.  All EBBR1
measurements of meteorological quantities during the period above are
invalid.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D931108.3
Start DateStart TimeEnd DateEnd Time
07/13/1993120011/02/19932121
Subject:
SGP/EBBR/E13 - pressure calibration
DataStreams:sgp30ebbrE13.b1
Description:
In the original Campbell CR10 software provided by the vendor (version 1),
the EBBR had incorrect calibration pressure sensor slopes and offsets.
The slopes and offset was carried through into version 2 of the
software and was not discovered by the mentor (me) until sometime later.
The calibration and slope did not deleteriously affect calculations in
the program since only a four percent reduction in atmospheric pressure
measurement resulted (the calculations are not very sensitive to small
errors in pressure). The vendor does not recall how the wrong
calibrations came to be used.   

Version 4 of the CR10 program includes the proper calibration and offset. 
This remedies the apparent offset problem (it was actually a calibration 
and offset problem). In comparisons with the co-located SMOS pressure
sensor, the difference between the SMOS and EBBR pressure values appeared
almost constant with time, hence the assumption of an offset problem.
However, the EBBR pressure sensor offsets are so large (a consequence of
tailoring the calibration curve to a small range of elevations in which the
calibration applies) that the very small error in slope was difficult to
recognize.

The outputted pressure values for the EBBR system can be corrected
with the following information and equations.  

         Old Slope     Old Offset        New Slope     New Offset

          0.01952        81.24            0.02031        81.27

   Correct Pressure =
               ((Current Pressure Data - 81.24)*0.02031/0.01952) + 81.27
                    =  1.04047*(Current Pressure Data) - 3.258
Measurements:sgp30ebbrE13.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D931108.4
Start DateStart TimeEnd DateEnd Time
07/13/1993120011/02/19932121
Subject:
SGP/EBBR/E13 - solid moisture correction
DataStreams:sgp30ebbrE13.b1
Description:
In the original EBBR software (Version 1) for the Campbell CR10 at the Central
Facility (E13), adjustment of the soil moisture for soil type was performed
differently than for the other EBBR systems.  This was supposed to have
been changed prior to installation (according to the vendor), but the
change was not made.  This adjustment was carried into Version 2 and was
not discovered by the mentor (me) until later.  A polynomial is used to
adjust the measured soil moisture for differences between the soil type at
the location of installation (clay-loam assumed) and the soil type (sand)
used in the calibration of the soil moisture sensor.  The adjustment in
the E13 EBBR only, was computed on the basis of a sandy-loam soil.

Presently, a clay-loam soil type is assumed for each EBBR location.  Soil
types at the extended facilities have not been characterized yet, although
there are hopes of doing so in the future.  The effect of using a
polynomial for sandy-loam soil instead of clay-loam soil is to decrease the
resultant soil moisture values by approximately 14.5% when the clay-loam
polynomial would indicate a soil moisture of 28.3%, and by approximately
38.3% when the clay-loam polynomial would indicate a soil moisture of 6.3%.
The normal range of soil moisture at the EBBR sites is approximately 3% to
35%.

The effect of the soil moisture decreases above on the adjustment to soil heat
flux plate measurements is less than 1.0%.  The effect on the change in
energy storage in the soil (determined from the change in soil temperature
over time) is a 10% decrease for a soil moisture of 28.3% and a decrease of
13.0% for a soil moisture of 6.3%.  The change in energy storage is typically
5% of the total surface energy budget during mid-day and 25% at night.
Therefore, the soil type adjustment error in the Central Facility EBBR
resulted in approximately a 0.5% error in the surface energy budget during
mid-day and 2.5% at night.  These are small and acceptable errors and
should not cause one to need to recalculate energy budget values.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_1
  • soil_heat_capacity_1
  • soil_moisture_2
  • soil_moisture_5
  • soil_heat_capacity_5
  • energy_storage_change_1
  • soil_heat_capacity_4
  • energy_storage_change_3
  • soil_moisture_3
  • soil_heat_capacity_3
  • soil_moisture_4
  • energy_storage_change_2
  • soil_heat_capacity_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)


Back To Table of Contents

DQRID : D940105.1
Start DateStart TimeEnd DateEnd Time
07/11/1993110012/01/19931830
Subject:
Incorrect readings for pressure sensor
DataStreams:sgp30ebbrE15.b1
Description:
ARM PROBLEM IDENTIFICATION FORM (PIF)

                            PIF No. P940105.1

Subject:  SGP/Ebbr - Incorrect readings for pressure sensor at E15

Submitted By:        David R. Cook
    Organization:    Argonne National Laboratory
    Date Submitted:  December 13, 1993

How may we contact you?
    e-mail:  cook@anler.er.anl.gov
    phone:   (708) 252-5840
    FAX:     (708) 252-9792

Submitter's Priority: 3
    [Critical-1   Very Important-2 Important-3 Inconvenient-4 Interesting-5]

Where was this Problem Identified:  DA
    [Site Data System-SDS      Experiment Center-EC]
    [Archive-A At              Field Instrument-FI ]
    [During Data Analyis-DA    Other- List Location]

Does this PIF result in a Software Change Request?  No
    Where:                     [ SDS,  EC, or  A ]

    Type:                      [Development-1 Problem-2  Enhancement-3]

    List Programs/Documents Affected:

    Configuration Identification:

Does problem impact data values or cause data loss?  Data values.
    which platform(s): EBBR, E15, Ringwood, OK

    Specify (or estimate) begin and end dates
          Begin Date   7/11/93
          End   Date  12/01/93   Time  1830 GMT

    Apparent cause of data loss, if known:

    SUGGESTED CAUSES:   Calibration Drift.
    [human error, component failure, temperature, lightning          ]
    [foreign matter, power loss, software failure,                   ]
    [communications failure, modification difficulites, specify other]


Problem Description/Change Description.

o For Instrument Problems ONLY,
        Identify MODE of Operation: Normal

o Give a brief explanation with details, attach examples and any supporting
  information.  This should include a description of analysis leading to
  identification of problem and, if known, recommended action.


Beginning July 11, 1993, the atmospheric pressure sensor at the E15
EBBR began indicating approximately 0.2 KPa lower than the colocated SMOS.
Between July 31 and August 22, 1993 the difference increased to between
0.25 and 0.30 KPa.  After August 22, the difference increased to 0.3 to
0.35 KPa and remained that way until December 1, 1993.  A comparison of the
EBBR pressure sensor with the portable standard on December 1, 1993
indicated that the EBBR sensor was 0.04 KPa higher than the standard; this
is excellent agreement considering that the uncertainty of the EBBR sensor
calibration is 0.15 KPa.  The consistent bias in EBBR pressure between July 11
and December 1 can be easily detected in comparisons with SMOS pressure data.
No EBBR data other than pressure was affected by the pressure problem;
calculations of specific heat at constant pressure (which includes the term
1/(p-vp)) times other terms (including p-.378*vp) result in no error to the
third decimal point at least in the resulting Bowen Ratio.  For example;
assume a common vapor pressure (vp) of 2.0 kPa, a common atmospheric pressure
of 97.0 kPa, and a corrupted atmospheric pressure of 96.65 kPa at the extreme.

       Uncorrupted                               Corrupted

(97.0-.378*2.0)/(97.0-2.0) = 1.0131   (96.65-.378*2.0)/(96.65-2.0) = 1.0131

   1.0131/1.0131 = 1.0000    There is no effect on the Bowen Ratio as a
                                       result of the corruption.

Therefore, no correction to the quantities calculated using pressure is
needed.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D940105.4
Start DateStart TimeEnd DateEnd Time
11/12/1993030011/15/19931830
Subject:
SGP/EBBR/E15 - Questionable data due to low voltage at E15
DataStreams:sgp30ebbrE15.b1
Description:
On November 11, 1993 at 0300 GMT the voltage level of the battery for the
EBBR at Ringwood (E15) dropped to too low a level for most of the
sensors to perform properly.  By 0700 GMT virtually all sensors were not
indicating properly.  This condition continued through 1830 GMT on November
15, 1993.  No data from this EBBR should be considered valid during the
period indicated, since the quality of data from all sensors is
questionable.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D940106.2
Start DateStart TimeEnd DateEnd Time
12/20/1993073012/22/19931500
Subject:
SGP/EBBR/E12 - Invalid data due to blown AEM fuse at E12
DataStreams:sgp30ebbrE12.b1
Description:
On December 20, 1993, before 0730 GMT, the fuse in the AEM (Automatic
Exchange Mechanism) of Pawhuska, OK (E12) EBBR blew out.  The AEM remained
nonfunctional until the fuse was replaced just before 1500 GMT on
December 22, 1993.  This situation resulted in the following invalid data:

5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
          vp_top, vp_bot, home

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, mv_home, tair_r,
           tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h, home_15, home_30

Bowen, h, and e can not be recalculated from the 15 minute and/or 5 minute data
since we cannot determine the position of the sensors on the AEM from the home
signal; home signal is near zero when there is no power to the AEM.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • home_signal_30
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D940106.5
Start DateStart TimeEnd DateEnd Time
12/31/1993195012/31/19932100
Subject:
SGP/EBBR/E13 - Invalid data during disconnection of AEM at E13
DataStreams:sgp30ebbrE13.b1
Description:
On December 31, 1993 at 1950 GMT the AEM on the Central Facility EBBR was
disconnected.  Another AEM was then connected, on which some testing was needed
before site operations could be confident that it was ready for field
installation at an extended facility.  At 2041 GMT the original AEM was
reconnected.  The following 5, 15, and 30 minute data between or for the stated
times below is invalid:

5 minute (1950 to 2045 GMT): tair_top, tair_bot, thum_top, thum_bot, hum_top,
          hum_bot, vp_top, vp_bot, home

15 minute (2000 to 2045 GMT): rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l,
           mv_home, tair_r, tair_l

30 minute (2000 through 2100 GMT): tair_top, tair_bot, thum_top, thum_bot,
           hum_top, hum_bot, vp_top, vp_bot, bowen, e, h, home_15, home_30
Measurements:sgp30ebbrE13.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_30
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_trh_bottom
  • home_signal_15
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D940511.2
Start DateStart TimeEnd DateEnd Time
05/06/1994151505/06/19941600
Subject:
SGP/EBBR/E13 - SM4 Replacement
DataStreams:sgp30ebbrE13.b1
Description:
Soil Moisture Probe #4 has been indicating large soil moistures in the past
couple of months.  At times the values have exceeded the upper limit of the
acceptable range.  This data could be considered questionable, although the
affect on average soil moisture and quantities affected by it is very small.
Therefore, I do not suggest additional flagging of the data other than that
imposed by the limits.  The probe was changed from S/N 92004 to 93004 on
May 6, 1994 at 1530 GMT.  During the exchange process a few selected periods
of soil moisture #4 data is incorrect, but not so different from the other
soil moisture probes as to have a significant affect on the average soil
moisture or the fluxes.

Additionally, the EBBR output was interrupted for a half hour while the
calibration of the new probe was entered into the CR10 data logger.
Therefore, all 5 minute data from 1535 to 1600 GMT, 15 minute data for 1545
and 1600 GMT, and 30 minute data for 1600 GMT is incorrect.

Furthermore, disturbance of the area near the #4 soil probes (temperature,
soil moisture, and heat flux) caused all three to be incorrect for the
following periods:

30 minute  1530 GMT

15 minute  1515 and 1530 GMT

5 minute   1515, 1520, 1525, and 1530 GMT.

Complete recovery by all three sensors did not occur for one day (which is
fairly typical for near surface installations), although the differences
from the other four sets of soil sensors did not deleteriously affect the
averages of the soil quantities.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_flow_4
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_4
  • corr_soil_heat_flow_4
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D940616.3
Start DateStart TimeEnd DateEnd Time
06/03/1994120006/08/19941515
Subject:
SGP/EBBR/E12 - Wind Direction
DataStreams:sgp30ebbrE12.b1
Description:
For much of the period above, a malfunction in the E12 EBBR wind direction
sensor (insect larvae shorting out the circuit board) caused incorrect
values for 5 minute res_ws, wind_d, and sigma_wd, 15 minute mv_wind_d, and
30 minute res_ws, wind_d, and sigma_wd.  Wind direction normally indicated
north (near 0 or 360 degrees); there were some times during the period when
wind directions looked good, but the lack of variation in direction and sigma
implies that the data is suspect.  Therefore, it would be wise to flag all
of the values listed above during the entire time period as incorrect.
The wind direction sensor (S/N 3081) was replaced with S/N 3042 at 1515 GMT
on June 8, 1994.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D940711.3
Start DateStart TimeEnd DateEnd Time
06/18/1994200006/22/19941600
Subject:
SGP/EBBR/E12 - Aspirator Failure
DataStreams:sgp30ebbrE12.b1
Description:
On June 18, 1994 the aspirator fan in the EBBR at E12, Pawhuska stopped
working.  This situation was not discovered until a Preventative
Maintenance visit by site operations personnel on June 22, 1994.  I
determined the time of the beginning of the malfunction from close
inspection of the sensible and latent heat flux data.  There is no aspiration
status output for the EBBRs, nor is one presently possible.  Wind speeds during
most of the period listed were sufficient to provide some (although
inadequate) aspiration to the temperature and relative humidity probes, making
it difficult for most users of the data to be able to tell (except in a few
circumstances) that the sensible and latent heat flux values produced were
incorrect.  All of the data fields listed below are incorrect for the period
listed above.  Latent and Sensible heat fluxes cannot be recomputed, as the
measurements that they are based on are what was corrupted.

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D940808.2
Start DateStart TimeEnd DateEnd Time
07/22/1994120008/04/19941600
Subject:
SGP/EBBR/E12 - Stopped Ventilation Fan
DataStreams:sgp30ebbrE12.b1
Description:
On August 4, 1994, a site operator discovered the ventilation fan of the
EBBR to be stopped; the fan guard was clogged with animal remains.
Inspection of the EBBR data from Pawhuska, OK, E12 indicates that this
condition occurred from July 22 through August 4.  Lack of ventilation of
the temperature and relative humidity sensors attached to the AEM results
in questionable measurements of air temperature, relative humidity, and all
quantities calculated from them, including sensible and latent heat fluxes.
The quantities that are questionable for the period indicated are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D940909.1
Start DateStart TimeEnd DateEnd Time
08/20/1994023008/31/19941542
Subject:
SGP/EBBR/E12 - Miscellaneous Problems Affecting Data
DataStreams:sgp30ebbrE12.b1
Description:
Three hardware problems occurred at E12, Pawhuska, OK in late August 1994.

On August 12 the wind direction sensor malfunctioned.  Therefore, all wind
direction, sigma, and resultant wind speed values for the period above are
incorrect.  The wind direction sensor was replaced on August 31.  Affected
data are:

        5 minute:  wind_d, sigma_wd, res_ws
        15 minute: mv_wind_d
        30 minute: wind_d, sigma_wd, res_ws.

Water accumulated in the AEM motor box and apparently caused a reduction in
the voltage level of the home signal (battery condition was very good and so
was not the cause); by late August 27 the hom30 level had fallen below the
minimum qc check level.  The AEM continued to exchange properly.  The minimum
qc level check is intended to help detect either a non-operating AEM or low
battery condition.  The Campbell CR10 software operates properly unless the
hom30 signal is thirty-five or greater.  So the low hom30 values do not
result in any incorrect data!!!.  I point this out because this situation
demonstrates a condition flagged by the qc checks, even though no effect on
the data has occurred.  The AEM box was dried out and new dessicant placed
in it on August 31.

On August 28, 1994 the left AEM housing ventilation fan ceased to operate
because of clogging of the ventilation system with debris.  Fifteen minute
data seems to indicate that the fan stopped operating just before 1245 GMT.
This is at least the third such incidence of clogging this summer at different
EBBRs.  The clog was removed and ventilation restored on August 31.  The lack
of ventilation caused improper measurements of temperature and
relative humidity in the left housing (these are quite obvious in the 15
minute data but difficult to detect in the 30 minute data) and therefore
incorrect values of sensible and latent heat.  Affected data are:

        5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top,
                   hum_bot, vp_top, vp_bot
        15 minute: rr_thum_l, mv_hum_l, tair_l
        30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top,
                   hum_bot, vp_top, vp_bot, bowen, e, h.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • bowen_ratio
  • Wind direction vector mean(wdir_vec_mean)
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_trh_bottom
  • home_signal_30
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • rh_bottom_fraction
  • wdir_vec_std
  • rh_top_fraction
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D941021.12
Start DateStart TimeEnd DateEnd Time
09/15/1994160009/29/19941430
Subject:
SGP/EBBR/E12 - Net Radiometer Hemisphere Changes
DataStreams:sgp30ebbrE12.b1
Description:
The upper hemisphere of the net radiometer at the site was punctured
allowing water to collect in the lower (and sometimes upper) section of the sensor. The 
punctures are most likely the result of migratory birds (a problem that we have experienced 
almost every year here at ANL also). The punctures (and water in some net radiometers) 
did not result in obvious invalidation of the data.

Whether there is water in the lower hemisphere or not, a small puncture of the upper 
hemisphere would not have a major effect on the net radiation measurement.  Significant 
amounts of water in the lower
hemisphere should have a major effect on nighttime measurements particularly, although 
that effect is hard to detect in the data. 
The date when the puncture occurred is approximate - but is certainly 
no more than two weeks before the hemisphere was replaced.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D941021.13
Start DateStart TimeEnd DateEnd Time
09/26/1994153010/11/19941910
Subject:
SGP/EBBR/E15 - Net Radiometer Hemisphere Changes
DataStreams:sgp30ebbrE15.b1
Description:
The upper hemisphere of the net radiometer at the site was punctured
allowing water to collect in the lower (and sometimes upper) section of the sensor. The 
punctures are most likely the result of migratory birds (a problem that we have experienced 
almost every year here at ANL also). The punctures (and water in some net radiometers) 
did not result in obvious invalidation of the data.

Whether there is water in the lower hemisphere or not, a small puncture of the upper 
hemisphere would not have a major effect on the net radiation measurement.  Significant 
amounts of water in the lower
hemisphere should have a major effect on nighttime measurements particularly, although 
that effect is hard to detect in the data. 
The date when the puncture occurred is approximate - but is certainly 
no more than two weeks before the hemisphere was replaced.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D941021.5
Start DateStart TimeEnd DateEnd Time
10/13/1994230010/14/19941900
Subject:
SGP/EBBR/E13 - Soil Temperature Aberations
DataStreams:sgp30ebbrE13.b1
Description:
For a period of not quite a day, soil temperature probe #4 indicated values
that were either too high or too low, for unknown reasons.  After Site
Operations personnel checked connectors and the probe itself, it recovered
to proper values.  The probe has functioned properly since then.  The times
and incorrect data fields are listed below.

15 minute: rr_ts4, 10/13/94: 2245 GMT; 10/14/94: 0000, 0200, 0230, 0515,
                  0600, 0630, 1300-1500, 1530-1715, 1815, 1845 GMT

30 minute: ts4, 10/13/94: 2300 GMT; 10/14/94: 0000, 0230, 0530-0630,
                  1300-1700, 1830-1900 GMT
           ces4, g4, ave_shf, e, h, 10/14/94: 0030, 0200-0230, 0600-0630,
                  1300-1900 GMT
Measurements:sgp30ebbrE13.b1:
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)


Back To Table of Contents

DQRID : D941021.6
Start DateStart TimeEnd DateEnd Time
09/03/1994190009/15/19941330
Subject:
SGP/EBBR/E12 - Low home_15 Values
DataStreams:sgp30ebbrE12.b1
Description:
The home signal values for the EBBR system installed at E12, Pawhuska, OK have
generally been lower than for the other EBBR systems.  However, during the
period above the home_15 value was often lower than 35, which is then
improperly interpreted by the CR10 software.  A home_15 value less than 35 is
interpreted as meaning that the AEM aspirated housings (which hold the
temperature and relative humidity sensors) are in the opposite orientation to
what they actually are.  The AEM continues to exchange properly, but the
resulting calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect.  On September 15, 1994 Site Operations personnel
refurbished the wiring for the left housing and the home_15 signal returned
to proper levels.

When 30 minute home_15 values are below 35, the data fields listed below are
incorrect.

5 minute:  home, tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot

15 minute: mv_home

30 minute: home_15, tair_top, tair_bot, thum_top, thum_bot, hum_top,
           hum_bot, vp_top, vp_bot, Bowen, e, h

It is possible to recalculate the Bowen ratio, e, and h by using the 15
minute data to compute the correct gradients of temperature and relative
humidity (two 15 minute periods are averaged to give a half hour value); the
orientation of the AEM is obvious in the 15 minute data, based on the home
signal (which is largest for the first 15 minutes of the half hour).  More
information on performing this recalculation can be obtained from the
mentor.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D941021.8
Start DateStart TimeEnd DateEnd Time
10/11/1994191510/11/19941930
Subject:
SGP/EBBR/E15 - Net Radiometer Hemisphere Changes
DataStreams:sgp30ebbrE15.b1
Description:
Incorrect data during hemisphere change.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D941208.1
Start DateStart TimeEnd DateEnd Time
12/02/1994193712/02/19942000
Subject:
SGP/EBBR/E13 - Net Radiation - Hemisphere Replacement
DataStreams:sgp30ebbrE13.b1
Description:
The upper hemisphere of the net radiometer was punctured (pinhole) and thus
was replaced at 1937 GMT on December 2, 1994.  This resulted in a spike in
the net radiation data.  5 minute q data for 1935, 1940, 1945, and
1955 GMT, 15 minute mv_q data for 1945 and 2000 GMT, and 30 minute q, e,
and h data for 2000 GMT are incorrect.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D950126.1
Start DateStart TimeEnd DateEnd Time
12/24/1994080012/25/19940100
12/13/1994043012/13/19940500
12/19/1994000012/19/19941600
12/30/1994173012/30/19941800
12/25/1994150012/25/19941600
12/18/1994090012/18/19941030
12/27/1994020012/27/19941700
12/20/1994020012/20/19940400
12/13/1994180012/13/19941830
12/23/1994083012/23/19942030
12/25/1994020012/25/19941400
12/25/1994170012/26/19941800
12/18/1994163012/18/19941930
Subject:
SGP/EBBR/E13 - Incorrect Soil Temperature #4
DataStreams:sgp30ebbrE13.b1
Description:
For periods of a number of days in December 1994, soil temperature probe #4
indicated incorrect values that were either too high or too low.  Site
Operations personnel replaced the sensor on December 30, 1994.  The times
and incorrect data fields are listed below.  Only half hour times are
listed.  The incorrect data on December 30 was the result of the process of
replacing the sensor during that time.

Data Fields:
15 minute: rr_ts4
30 minute: ts4, ces4, g4, ave_shf, e, h

Dates and Times (GMT):
12/13/94  0500, 1830
12/18/94  0900-1030, 1630-1930
12/19/94  0000-1600
12/20/94  0200-0400
12/23/94  0830-2030
12/24/94  0800-2330
12/25/94  0000-0100, 0200-1400, 1530, 1600, 1700-2330
12/26/94  0000-1800
12/27/94  0200-1700
12/30/94  1730-1800

Recomputation of the change in energy storage in the soil could be done
roughly from the soil temperature sensors that were still working (roughly
because the difference in soil temperature with time is determined with
real-time (one minute samples) data, not from the 15 or 30 minute data).
However, this would require considerable effort.  The process for doing so
is therefore not stated here.  Contact the mentor for more information if
neccesary.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D950126.4
Start DateStart TimeEnd DateEnd Time
12/31/1994214001/01/19951730
Subject:
SGP/EBBR/E15 - Frozen Wind Speed Instrument
DataStreams:sgp30ebbrE15.b1
Description:
On December 31, 1994 EBBR wind speed instrument froze in place from icing.
Wind speeds increased sufficiently on January 1, 1995 to break the
anemometer free.  The wind direction instrument was not affected.  The times
and fields that are incorrect are shown below.

5 minute:  wind_s, res_ws  12/31 2140 GMT - 1/1 1705 GMT
15 minute: wind_s          12/31 2145 GMT - 1/1 1715 GMT
30 minute: wind_s, res_ws  12/31 2200 GMT - 1/1 1730 GMT
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D950626.1
Start DateStart TimeEnd DateEnd Time
02/14/1995110002/14/19951730
Subject:
SGP/EBBR/E13 - Frozen Wind Speed Sensor
DataStreams:sgp30ebbrE13.b1
Description:
DQR No:                               Platform: EBBR

Subject: Frozen Wind Speed Sensor

Date Submitted: JUNE 22, 1995
Submitted By:                         _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: EBBR/ Wind Speed
        What level data: (raw,a0,a1,b1,c1 etc): a1 (15 and 30 minute)
                                                a0 (5 minute)

    What location was the data collected at: E13, Central Facility

    Period of time in question
        Begin Date 2/14/95   Time 1100 GMT
        End                  Time 1730 GMT

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:

On February 14, 1995 a frontal system deposited freezing rain in central
Oklahoma that resulted in the EBBR wind speed instrument becoming frozen in
place at the Central Facillity (E13) for part of a day.  All 5, 15, and 30
minute data values indicated below are incorrect for the period listed above.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws

Other observations/measurements impacted by this problem:

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data with this comment.

Data Processing Notes                Date

-------------------------------------------------------------------
END
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D950626.15
Start DateStart TimeEnd DateEnd Time
04/23/1995002004/26/19951630
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp30ebbrE12.b1
Description:
For most of the period above, a malfunction in the E12 EBBR wind direction
sensor caused the following data values to be incorrect:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.

Wind direction normally indicated near north or 135 degrees (the latter
indicates a malfunction).

The wind direction sensor (S/N 3036) was replaced with S/N 3034 at 1620 GMT
on April 26, 1995.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D950626.16
Start DateStart TimeEnd DateEnd Time
06/06/1995070006/07/19951830
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp30ebbrE12.b1
Description:
For the period indicated, a malfunction in the E12 EBBR wind direction
sensor caused the following data values to be incorrect:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.

Wind direction normally indicated smaller or larger than it should have.
The affected time period was determined from comparison with data from E7,
Elk Falls EBBR, which is located north of E12.

The wind direction sensor (S/N 3034) was replaced with S/N 3039 at 1822 GMT
on June 7, 1995.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D950626.2
Start DateStart TimeEnd DateEnd Time
03/07/1995024503/08/19951640
Subject:
SGP/EBBR/E13 - Frozen Wind Speed Sensor
DataStreams:sgp30ebbrE13.b1
Description:
On March 7, 1995 freezing rain stopped the cups of the EBBR wind
speed instrument at the Central Facility (E13).  All 5, 15, and 30
minute data values indicated below are incorrect for the period listed above.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D950626.20
Start DateStart TimeEnd DateEnd Time
06/06/1995164506/06/19951830
Subject:
SGP/EBBR/E15 - Battery Voltage Drop, Storage Module Change
DataStreams:sgp30ebbrE15.b1
Description:
For a short period on June 6, 1995 at E15, Ringwood, OK, two events
resulted in a loss of data: replacement of the storage module and a low
battery condition.  The low battery condition apparently affected only the
1815 GMT data output.  All data during this period is missing (1645-1800
GMT) of incorrect (1815-1830).
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D950626.3
Start DateStart TimeEnd DateEnd Time
03/07/1995014503/07/19951725
Subject:
SGP/EBBR/E15 - Frozen Wind Speed Sensor
DataStreams:sgp30ebbrE15.b1
Description:
On March 7, 1995 freezing rain stopped the cups of the EBBR wind
speed instrument at Ringwood, OK (E15).  All 5, 15, and 30
minute data values indicated below are incorrect for the period indicated.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D950626.7
Start DateStart TimeEnd DateEnd Time
02/17/1995140002/22/19951500
Subject:
SGP/EBBR/E13 - Reprocess: Soil Temperature Malfunction
DataStreams:sgp30ebbrE13.b1
Description:
For several days, soil temperature probe #4 indicated values
that were either too high or too low, for unknown reasons.  After Site
Operations personnel checked connections, it recovered to proper values.
Affected quantities are shown below.

15 minute: rr_ts4

30 minute: ts4, ces4, g4, ave_shf, e, h

Sensible, latent, and soil heat fluxes need to be recalculated using the
change in energy storage of probes 1-3 and 5, as follows.

ave_shf = (g1 + g2 + g3 + g5)/4

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q)
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_4
  • energy_storage_change_4
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D950719.2
Start DateStart TimeEnd DateEnd Time
07/03/1995060007/07/19951605
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp30ebbrE12.b1
Description:
For the period indicated, a malfunction in the E12 EBBR wind direction
sensor caused the following data values to be incorrect:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.

Wind direction normally indicated small values (15 to 25 degrees) from 3 July
1995 at 0600 GMT through 6 July 1995 at 1500 GMT (at which time the sensor
was removed).  No sensor was in place between 6 July 1995 at 1500 GMT and 7
July 1995 at 1605 GMT (at which time a new sensor was installed).
 Old sensor S/N K3039, new S/N K3033.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D950815.2
Start DateStart TimeEnd DateEnd Time
08/01/1995150008/02/19951615
Subject:
SGP/EBBR/E13 - Low Battery Voltage and AEM Left on Manual
DataStreams:sgp30ebbrE13.b1
Description:
Low battery voltage caused some data values to be incorrect beginning at
1500 GMT on August 1, 1995.  The data should be carefully inspected to
determine which values are incorrect.

During replacement of the battery at the Central Facility EBBR on August
1, 1995, the AEM exchange toggle switch was left in the manual position,
which caused the right aspirator to remain in the home position until the
switch was correctly placed in the exchange position at 1616 GMT on August
2, 1995.  All 5, 15, and 30 minute values of temperature, relative humidity
, vapor pressure, bowen, e, and h are incorrect during the period. 15 and
30 minute values are also incorrect at 1630 GMT.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D950816.2
Start DateStart TimeEnd DateEnd Time
07/20/1995170009/14/19952359
Subject:
SGP/EBBR/E12 - AEM Failure
DataStreams:sgp30ebbrE12.b1
Description:
As noted in a previous DQR, the home signal values at E12, Pawhuska, OK
began decreasing in July.  At the beginning of the period listed, the home
30 value dropped below 15; this causes a data quality message to be output in
the site operations log as the stated acceptable range for home 30 is 15 to
34.999999.  No data is incorrect as a result of this condition.

The home 15 value dropped below 35 beginning July 21, 1995, sometime after
2000 GMT; this causes a data quality message to be output in the site
operations log as the stated acceptable range for home 15 is 35 to
70.  Data is incorrect as a result of this condition, that being 30 minute e,
h, and bowen.

The home values frequently dropped below their proper levels until 10 August,
1995, at some time after 1100 GMT, when the set screws in the AEM would no
longer hold and the aspirator units were stranded inbetween the home
positions.  Thereafter, the reported home signals were negative.  All 30
minute e, h, and bowen data are incorrect for this condition.

On August 16, 1995, at about 1600 GMT, site operators determined that they
could not repair the AEM on-site and they determined that the replacement AEM
that they took with them has an electronic short.  Therefore, the AEM was
left in manual mode (no exchange).  Replacement of the AEM will not take
place until a working spare is available and all 30 minute e, h, and bowen
data will be incorrect until then.

I will submit another DQR or addendum when successful replacement of the
AEM is accomplished.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • home_signal_30
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D950816.3
Start DateStart TimeEnd DateEnd Time
06/23/1995000008/16/19952359
Subject:
SGP/EBBR/E15 - AEM Home 15 Values High
DataStreams:sgp30ebbrE15.b1
Description:
Beginning on June 23, 1995, the home 15 value indicated greater than 70 at
times.  This indicates that the home 15 and 30 outputs are somehow being
electronically added in the AEM.  Home 15 values above 70 cause a data quality
message to be output in the site operations log as the stated acceptable range
for home 15 is 35 to 70.  However, no data is incorrect as a result of this
condition.

No replacement AEM is available and site operations was not able to
diagnose the problem.  At present, data quality is not jeopardized.

I will submit another DQR or addendum when successful repair or replacement of
the AEM is accomplished.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D950828.1
Start DateStart TimeEnd DateEnd Time
08/18/1995123008/18/19951500
08/16/1995060008/16/19951530
08/19/1995110008/19/19951500
08/20/1995090008/20/19951500
08/21/1995060008/21/19951500
Subject:
SGP/EBBR/E13 - Battery Voltage Drop
DataStreams:sgp30ebbrE13.b1
Description:
Sometime before August 16, 1995 the AC/DC converter was switched off and
the instrument heaters were switched on.  The solar panel was not able to
keep the battery voltage up under these conditions.  Much of the data for
the periods indicated is incorrect, especially data from the sensors that
require 12 volts DC power.  The data would have to be inspected to
determine what data is correct and what is incorrect.  It would be safest to
exclude all data from those periods from any analysis.  Site operations
switched the heaters off and turned the converter back on on August 21,
1995.

As reported in a recent DQR, the fluxes from the EBBR are incorrect
presently because of a malfunctioning T/RH probe; no spares are presently
available.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D950908.1
Start DateStart TimeEnd DateEnd Time
08/27/1995161509/14/19951600
Subject:
SGP/EBBR/E15 - AEM Not Exchanging
DataStreams:sgp30ebbrE15.b1
Description:
On August 27, 1995 at approximately 1615 GMT the upper sprocket shaft of the AEM
broke in two, causing the AEM to stop exchanging.  The home signal values
then remained at around 22 for both home_15 and Home_30.  On August 28 site
operations personnel removed the fuse (to prevent exchange) with the left
aspirator in the down position.  The home signal values remained around
-2.3 after that. The AEM will remain in this condition until a replacement
is available.

Therefore, the calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for all times after August 27, 1995 at 1615 GMT.  The data
fields listed below are incorrect after this time:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top,
           hum_bot, vp_top, vp_bot, Bowen, e, h

It is not possible to reliably calculate the Bowen ratio, e, and h using the
15 minute data.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D950908.3
Start DateStart TimeEnd DateEnd Time
08/16/1995001508/30/19951757
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp30ebbrE12.b1
Description:
For the period above, a malfunction in the E12 EBBR wind direction
sensor caused the wind direction to output a constant 212 degrees.  Site
operations replaced the sensor (S/N K3033) with K3042.  The following data
values are incorrect for the period listed:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D950921.2
Start DateStart TimeEnd DateEnd Time
08/27/1995161509/14/19951630
Subject:
SGP/EBBR/E15 - AEM Replaced
DataStreams:sgp30ebbrE15.b1
Description:
Please see DQR P950908.1, where this problem was first documented.

On August 27, 1995 at approximately 1615 GMT the upper sprocket shaft of the AEM
broke in two, causing the AEM to stop exchanging.  The home signal values
then remained at around 22 for both home_15 and Home_30.  On August 28 site
operations personnel removed the fuse (to prevent exchange) with the left
aspirator in the down position.  The home signal values remained around
-2.3 after that.  On 14 September 1995, site operations personnel replaced
the AEM (serial numbers unknown) and it has operated correctly since then.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for all times during the period listed above.  The data
fields listed below are incorrect:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top,
           hum_bot, vp_top, vp_bot, Bowen, e, h

It is not possible to reliably calculate the Bowen ratio, e, and h using the
15 minute data.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D950921.3
Start DateStart TimeEnd DateEnd Time
07/20/1995170009/14/19951830
Subject:
SGP/EBBR/E12 - AEM replacement
DataStreams:sgp30ebbrE12.b1
Description:
Please see DQR P950816.2, where this problem was first documented.

As noted in a previous DQR, the home signal values at E12, Pawhuska, OK
began decreasing in July.  At the beginning of the period listed, the home
30 value dropped below 15; this causes a data quality message to be output in
the site operations log as the stated acceptable range for home 30 is 15 to
34.999999.  No data is incorrect as a result of this condition.

The home 15 value dropped below 35 beginning July 21, 1995, sometime after
2000 GMT; this causes a data quality message to be output in the site
operations log as the stated acceptable range for home 15 is 35 to
70.  Data is incorrect as a result of this condition, that being 30 minute e,
h, and bowen.

The home values frequently dropped below their proper levels until 10 August,
1995, at some time after 1100 GMT, when the set screws in the AEM would no
longer hold and the aspirator units were stranded inbetween the home
positions.  Thereafter, the reported home signals were negative.  All 30
minute e, h, and bowen data are incorrect for this condition.

On August 16, 1995, at about 1600 GMT, site operators determined that they
could not repair the AEM on-site and they determined that the replacement AEM
that they took with them has an electronic short.  Therefore, the AEM was
left in manual mode (no exchange).  All 30 minute e, h, and bowen data are
incorrect until the end of the period listed above.

On 13 September 1995 site operations personnel replaced the AEM
(old S/N 92005, new S/N 94008).  The new AEM would not exchange when the
right sensor was in the home position: this was confirmed on 14 September
when site operations personnel again visited the site.  However, soon after
the site operations personnel left Pawhuska on 14 September (at 1810 GMT),
the AEM started to exchange properly (data correct for 1900 GMT and after).
The AEM continues to operate properly.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • home_signal_30
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D951113.1
Start DateStart TimeEnd DateEnd Time
10/26/1995000011/03/19952045
Subject:
SGP/EBBR/E13 - Wind Direction Set Pin Slippage
DataStreams:sgp30ebbrE13.b1
Description:
The set pin bolt on the wind vane loosened, allowing the vane to turn on
the shaft.  Wind directions are incorrect as a result, for the period
listed above.  The bolt was tightened on 3 Nov 95 so that correct wind
directions would result.

Values that are incorrect for the period are:

5 minute:   wind_d, res_ws, sigma_wd

15 minute:  mv_wind_d

30 minute:  wind_d, res_ws, sigma_wd
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D951113.6
Start DateStart TimeEnd DateEnd Time
11/07/1995000011/07/19951400
11/04/1995120011/04/19951400
11/05/1995033011/05/19951430
11/06/1995000011/06/19951530
11/08/1995000011/08/19951400
Subject:
SGP/EBBR/E13 - Battery voltage drop
DataStreams:sgp30ebbrE13.b1
Description:
On Friday 2 November, 1995 the instrument heaters were switched on.  By
4 November, the solar panel was not able to maintain the battery voltage for
the cold night conditions that existed.  On Monday, 5 November the heaters
were turned off, but the poor condition of the battery did not allow it,
once partially drained, to recharge sufficiently for nighttime conditions.
On 8 November, at 2106 GMT, the battery was replaced (resulting in missing
data for 2030-2130 GMT).  Most of the data for the period above is incorrect,
especially data from the sensors that require at least 11 volts DC power.
The data that is incorrect is listed below.

5 minute:   tref, tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
            vp_top, vp_bot, q, pres, home

15 minute:  rr_thum_r, rr_thum_l, rr_ts1, rr_ts2, rr_ts3, rr_ts4, rr_ts5,
            rr_tref, mv_hum_r, mv_hum_l, mv_pres, mv_home, mv_q, mv_hft1,
            mv_hft2, mv_hft3, mv_hft4, mv_hft5, tair_r, tair_l

30 minute:  tair_top, tair_bot, tref, thum_top, thum_bot, hum_top, hum_bot,
            vp_top, vp_bot, pres, home_15, home_30, bowen, e, h, shf, shf1,
            shf2, shf3, shf4, shf5, c_shf1, c_shf2, c_shf3, c_shf4, c_shf5,
            ts1, ts2, ts3, ts4, ts5, q, g1, g2, g3, g4, g5, ces1, ces2,
            ces3, ces4, ces5

Periods of time affected (these are the 30 minute periods that are
incorrect - incorrect 5 and 15 minute data may also occur for all or part
of the previous half hour):

4 Nov 95: 1200-1400 GMT
5 Nov 95: 0330-1430 GMT
6 Nov 95: 0000-1530 GMT
7 Nov 95: 0000-1400 GMT
8 Nov 95: 0000-1400 GMT
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • temp_reference
  • corr_soil_heat_flow_3
  • home_signal_30
  • energy_storage_change_4
  • energy_storage_change_5
  • corr_soil_heat_flow_5
  • vapor_pressure_top
  • corr_soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_1
  • temp_air_bottom
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 5(soil_temp_5)
  • home_signal_15
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • surface_soil_heat_flux_5
  • temp_air_top
  • bowen_ratio
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • temp_trh_top
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • soil_heat_flow_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • vapor_pressure_bottom
  • soil_heat_flow_5
  • soil_heat_flow_4
  • Net radiation(net_radiation)
  • energy_storage_change_1
  • energy_storage_change_3
  • energy_storage_change_2
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D951116.1
Start DateStart TimeEnd DateEnd Time
11/11/1995070011/11/19950730
Subject:
SGP/EBBR/E13 - AEM Exchange Stopped in Snow and Freezing Rain
DataStreams:sgp30ebbrE13.b1
Description:
On the night of November 10-11, a north-south line from south central
Kansas through south central Oklahoma received snow and freezing rain and experienced
below freezing temperatures.  This caused the EBBR automatic exchange mechanism (AEM) to
stop exchanging temporarily.   

Note that temperatures, relative humidities, and vapor pressures are not affected; these
are correct as measured, but the height at which the measurements occurred must be
determined from the home signal value.
Measurements:sgp30ebbrE13.b1:
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D951116.4
Start DateStart TimeEnd DateEnd Time
11/11/1995011511/15/19952359
Subject:
SGP/EBBR/E15 - AEM Exchange Stopped in Snow and Freezing Rain
DataStreams:sgp30ebbrE15.b1
Description:
On the night of November 10-11, a north-south line from south central
Kansas through south central Oklahoma received snow and freezing rain and experienced 
below freezing temperatures.  This caused the EBBR automatic exchange mechanism (AEM) to stop 
exchanging temporarily.   

Note that temperatures, relative humidities, and vapor pressures are not affected; these 
are correct as measured, but the height at which the measurements occurred must be 
determined from the home signal value.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D951127.3
Start DateStart TimeEnd DateEnd Time
11/18/1995031511/21/19952130
Subject:
SGP/EBBR/E12 - AEM Failure/Right Radiation Shield OFF
DataStreams:sgp30ebbrE12.b1
Description:
On 18 November 1995 the AEM at E12, Pawhuska, OK stopped exchanging, with
the right radiation shield at the bottom position.  The 30 minute home
signal reflects this condition.  During the 21 November PM visit, the site
operators also found that the right radiation shield was no longer attached
to the AEM, but was dangling by its conduit.  It is not clear whether both
conditions occurred simultaneously.  Comparison of E12 data with that at
the Central Facility indicates that E12 data was correct on 17 November.

The AEM had stopped exchanging because a transistor became unsoldered from
the AEM circuit board.  Site operators repaired this and reattached the
right radiation shield to bring the system to operational status at 2130
GMT.

All 30 minute latent heat (e), sensible heat (h), and Bowen ratio (bowen)
data during the period above are incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D951220.5
Start DateStart TimeEnd DateEnd Time
12/14/1995165012/14/19952100
Subject:
SGP/EBBR/E15 - Annual calibration changeout
DataStreams:sgp30ebbrE15.b1
Description:
On December 14, 1995 the changeout for annual calibration occurred at E15,
Ringwood, OK.  Between 1650 and 2050 GMT no data was remotely collected.
Furthermore, 5 minute data for 2050 GMT is incorrect, 15 minute data for
2045 GMT is incorrect, and 30 minute data for 2100 GMT is incorrect.
A rather large jump in soil moisture appears in the data after the
installation was completed (the bags holding the probes were soaked with water
before installation).  Soil measurements indicated greater than ambient
soil moisture  until a rain on late 18 December saturated the soil; after this
period the probes reflected actual soil moisture conditions.  The larger than
normal soil moistures have little impact on the small soil heat flux during
this time of year, and thus no significant affect on computed sensible and
latent heat fluxes.
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D951220.6
Start DateStart TimeEnd DateEnd Time
12/13/1995230012/14/19951430
12/13/1995040012/13/19951800
12/15/1995074512/15/19951515
12/09/1995053012/09/19951415
Subject:
SGP/EBBR/E13 - battery voltage drop
DataStreams:sgp30ebbrE13.b1
Description:
The E13 battery condition was such that the solar panel was not able to
keep the battery voltage up (greater than 11 V DC) under cloudy conditions.
The data for the periods above is incorrect; many sensors require at least
11 volts DC power.  On 15 December 1995 at 1900 GMT the EBBR lost it's
connection to the site data system; data after this period will be discussed
in a separate DQR.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D960104.4
Start DateStart TimeEnd DateEnd Time
12/18/1995184512/19/19951755
Subject:
SGP/EBBR/E15 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE15.b1
Description:
Freezing rain, snow, and below freezing conditions during 18-19 January
1995 caused the wind speed sensor cups to freeze in a stopped state at E15,
Ringwood, OK on 18 January 1995.  When temperatures rose to above freezing on
19 January, the ice thawed and the cups turned freely again.

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D960119.1
Start DateStart TimeEnd DateEnd Time
12/20/1995160001/16/19962030
Subject:
SGP/EBBR/E15 - Reprocess: Soil Temperature Probe Malfunction
DataStreams:sgp30ebbrE15.b1
Description:
Malfunction of soil temperature probe #3 at 157, Ringwood, OK resulted in
incorrect data values for 7 fields for the period of time listed above.  The
soil temperature value from probe #3 went offscale, resulting in a zero value
for the soil energy storage term calculated from that probe and thus no
contribution to the total soil heat flux for soils set 4 and the same for
average soil heat flux.  This led to incorrect sensible and latent heat
flux values.  The probe may have become disconnected during the 20 December
site operations preventative maintenance visit.  However, it also had
rodent chew damage and so was removed and replaced.

The fields that are incorrect are:

30 minute: ts3, ces3, g3, ave_shf, e, h

15 minute: rr_ts3.

Soil temperature probe #3 was replaced at 2030 GMT on 16 January 1996.
The old S/N was 95043, the new S/N is 93018.  Sensible and latent heat fluxes
can be recomputed by averaging the soil heat flux from the four sets of
functioning soil probes; use the following equations:

ave_shf = (g1 + g2 + g4 + g5)/4

e = -(q +ave_shf)/(1 + bowen)

h = e * bowen,

where g is total soil heat flow, q is net radiation, and bowen is Bowen
Ratio.
Measurements:sgp30ebbrE15.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_3
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 3(soil_temp_3)
  • energy_storage_change_3
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D960119.2
Start DateStart TimeEnd DateEnd Time
12/29/1995180012/29/19951815
12/21/1995063012/22/19951445
01/04/1996053001/04/19961430
01/05/1996204501/06/19961445
12/27/1995021512/27/19951445
01/12/1996023001/12/19961445
01/04/1996150001/04/19961645
01/14/1996003001/14/19961445
01/15/1996004501/15/19961600
12/25/1995033012/25/19951515
01/05/1996193001/05/19962000
12/26/1995023012/26/19951445
01/09/1996074501/09/19961415
01/08/1996030001/08/19961445
12/24/1995024512/24/19951445
12/28/1995000012/29/19951700
12/22/1995223012/23/19951445
01/11/1996013001/11/19961430
01/15/1996233001/16/19962015
12/29/1995193001/03/19961430
01/07/1996050001/07/19961500
01/10/1996073001/10/19961615
01/04/1996190001/05/19961730
01/13/1996010001/13/19961445
Subject:
SGP/EBBR/E15 - Battery Voltage Drop
DataStreams:sgp30ebbrE15.b1
Description:
From the installation of the changeout unit at E15 on 15 December 1995, the
battery exhibited a slow decline in voltage. However, after a day of the
AEM not operating, site operations restarted the AEM on 20 December 1995 and
the battery condition declined more rapidly, such that the solar panel was not
able to keep the battery voltage up (greater than 11 V DC) for nighttime
conditions, even after a cloudless day.  Battery voltage first dropped below 11
volts at 0635 GMT on 21 December.  I requested that the solar panel voltage
regulator be tested.  On 16 January 1996, site operations found that the
fuse in the solar panel voltage regulator was loose.  After the fuse was
repositioned, the battery voltage increased almost immediately to 13.5
volts and has been good since.

All data for the periods above should be considered incorrect; many sensors
require at least 11 volts DC power and the performance of the CR10 data
logger can not be trusted at less than 11 volts.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • East longitude(lon)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D960320.3
Start DateStart TimeEnd DateEnd Time
01/23/1996073001/24/19961615
01/18/1996050001/18/19962100
Subject:
SGP/EBBR/E12 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE12.b1
Description:
Freezing rain, snow, and below freezing conditions during 18 and 23 January 
1996 caused the wind speed sensor cups to freeze in a stopped state at E12, 
Pawhuska, OK.  The cups were freed up later on 18 January when the wind speed 
rose to above 10 meters per second.  When temperatures rose to above freezing 
on 24 January 1996, the ice thawed and the cups turned freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D960508.5
Start DateStart TimeEnd DateEnd Time
04/11/1996155004/11/19961640
Subject:
SGP/EBBR/E12 - 3-month check
DataStreams:sgp30ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D960508.6
Start DateStart TimeEnd DateEnd Time
05/06/1996175505/06/19961835
Subject:
SGP/EBBR/E13 - 3-month check
DataStreams:sgp30ebbrE13.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D960508.7
Start DateStart TimeEnd DateEnd Time
04/23/1996161004/23/19961703
Subject:
SGP/EBBR/E15 - 3-month check
DataStreams:sgp30ebbrE15.b1
Description:
During EBBR 3-month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D960606.1
Start DateStart TimeEnd DateEnd Time
05/24/1996180005/24/19962130
Subject:
SGP/EBBR/E13 - Annual Calibration changeout
DataStreams:sgp30ebbrE13.b1
Description:
On May 24, 1996 the changeout for annual calibration occurred at E13,
Central Facility, OK.  Between 1800 and 2130 GMT no data was remotely collected.
Furthermore, 5 minute data inbetween 1800 and 2130 is incorrect, 15 minute data 
between 1800 and 2130 is incorrect, and 30 minute data for 2130 GMT is 
incorrect.  A large jump in soil moisture appears in the data after the 
installation was completed (the soil bags holding the probes had a greater 
than ambient soil moisture).  Soil measurements indicated greater than ambient 
soil moisture until a rain just after 0600 GMT on 1 June saturated the soil; 
after this period the probes reflected actual soil moisture conditions.  

The larger than normal soil moistures have some impact on the soil heat flux 
during this time of year, and thus soil heat flux from the soil flow plates 
and soil temperature probes, as well as average soil heat flux, computed 
sensible and latent heat fluxes; these quantities should be considered to 
be incorrect from 24 June at 2130 GMT until about 1200 GMT on June 1.

Because of communication problems, data is missing from the time of the 
EBBR installation until 29 May 1996 at about 1815 GMT.  This data may be 
recovered from the sneakernetted data set.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_3
  • energy_storage_change_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D961122.11
Start DateStart TimeEnd DateEnd Time
08/20/1996070008/30/19961830
Subject:
SGP/EBBR/E13 - Wind Direction Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
Wind direction was incorrect during the period indicated due to a sensor 
electronics failure.  On 30 August 1996 site operations replaced S/N K3035
with S/N K3034.  Correct data collection resumed.

Values that are incorrect for the period are:

5 minute:   wind_d, res_ws, sigma_wd

15 minute:  mv_wind_d

30 minute:  wind_d, res_ws, sigma_wd
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D961122.23
Start DateStart TimeEnd DateEnd Time
10/25/1996160010/25/19961640
Subject:
SGP/EBBR/E12 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp30ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D961122.24
Start DateStart TimeEnd DateEnd Time
11/18/1996194211/18/19962022
Subject:
SGP/EBBR/E13 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp30ebbrE13.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D961122.25
Start DateStart TimeEnd DateEnd Time
11/05/1996165811/05/19961732
Subject:
SGP/EBBR/E15 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp30ebbrE15.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D961122.3
Start DateStart TimeEnd DateEnd Time
10/09/1996100010/09/19962000
Subject:
SGP/EBBR/E12 - Annual Calibration Changeout
DataStreams:sgp30ebbrE12.b1
Description:
On 9 October 1996 the EBBR changeout for annual calibration occurred at 
E12, Pawhuska, OK.  SEBS unit 10 was removed and unit 1 was installed.  Between 
1000 and 1500 GMT no data was collected.  Data for half hours 1530-2000 GMT is 
incorrect; 3 month calibration checks were being performed.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • North latitude(lat)
  • East longitude(lon)
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Altitude above mean sea level(alt)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D961122.8
Start DateStart TimeEnd DateEnd Time
09/24/1996171509/24/19961730
Subject:
SGP/EBBR/E12 - Left Air Temperature Thermocouple Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The left air temperature thermocouple was offscale, for unknown reasons, for 
1715 GMT for 15 minute, and 1730 GMT for 30 minute air temperature values.

The malfunction of the air temperature thermocouple results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux during the period indicated. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_l

30 minute: tair_top, tair_bot, bowen, e, and h
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D961122.9
Start DateStart TimeEnd DateEnd Time
07/13/1996000010/09/19962359
Subject:
SGP/EBBR/E12 - Battery Voltage Low - Fluxes Affected
DataStreams:sgp30ebbrE12.b1
Description:
The battery condition deteriorated over time so that the solar panel was not 
always able to keep the battery voltage high enough to produce correct home 
signal values.  The home 15 signal was too low much of the period above, 
with home 30 being low also occasionally.  The home signal qc checks should 
be consulted to determine which half hour values of sensible (h) and latent (e)
heat fluxes are incorrect; no other data values were affected.  The first 
occurrence of low home 15 signal appears to be 0630 GMT on 13 July 1996.  
Battery voltage did not drop low enough to cause any sensors to stop 
functioning.  The battery was replaced on 9 October 1996 at 2000 GMT, 
during annual calibration changeout of the entire EBBR unit (the mentor 
assumes that the battery was replaced - no instrument maintenance reports 
are available for that time).
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • Latent heat flux(latent_heat_flux)
  • home_signal_30
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D970330.1
Start DateStart TimeEnd DateEnd Time
02/07/1997053002/07/19971340
Subject:
SGP/EBBR/E13 - Frozen Wind Speed Sensor
DataStreams:sgp30ebbrE13.b1
Description:
On February 7, 1997 freezing rain stopped the cups of the EBBR wind 
speed instrument at the Central Facility (E13).  All 5, 15, and 30 
minute data values indicated below are incorrect for the period listed.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D970330.2
Start DateStart TimeEnd DateEnd Time
12/18/1995184512/19/19951755
Subject:
SGP/EBBR/E15 - Wind Speed Cups frozen
DataStreams:sgp30ebbrE15.b1
Description:
Freezing rain, snow, and below freezing conditions during 18-19 January 
1995 caused the wind speed sensor cups to freeze in a stopped state at E15, 
Ringwood, OK on 18 January 1995.  When temperatures rose to above freezing on 
19 January, the ice thawed and the cups turned freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D970401.1
Start DateStart TimeEnd DateEnd Time
03/20/1997225503/31/19972359
Subject:
Controlled burn at E12 on 3/20/97 and affected data
DataStreams:sgp30ebbrE12.b1
Description:
DQR No:                               Platforms:  sgpsirosE12
                                                  sgpebbrE12

Subject: Controlled burn at E12 on 3/20/97 and affected data

Date Submitted:  3/31/97
Submitted By: Mike Splitt             ___  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      _x_  Other _Site_Scientist_Team_
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at problems@arm.gov.

Platform/Measurement:
        What level data: (raw,a0,a1,b1,c1 etc):
             all levels
    What location was the data collected at: sgp E12
 
    Period of time in question
        Begin Date   3/20/97  Time   22:55    (GMT)
        End Date      *       Time     :      (GMT)

* The "end date" is not necessarily in need of definition. The EBBR data
  appears to be directly affected for a period of about one hour. The
  effect on the local shortwave albedo will be longer lasting and could 
  be said to "end" when the vegetative state recovers to being representative
  of similar areas.

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 _x_  others 
 
 Discussion of Problem:

This report is reflective of a change in environmental conditions thought
to be worth noting at E12, Pawhuska, and does not concern any issue of
substandard sensor performance. 

A contolled burn was conducted at the the Pawhuska Extened Facillity (E12)
by the Tallgrass Prairie Preserve. The Preserve director, Bob Hamilton,
contacted the ARM SGP Site prior to the activity which allowed Site Operations
to take precautionary steps. Danny Nelson reported the following activities by
Site Operations:

1)  Site Ops cut and removed all dried grass within the EF fence and
also to a 10' perimeter around the outside of the fence.  Final grass
height was 1-3".  This was done on Monday the 17th of March.

2)  Tallgrass Prairie Preserve personnel put down a 10' wet line around
our EF prior to the burn on the 20th, so the EF area was not burned.

3)  Site Ops had originally planned to deploy a field crew to inspect
the site on the day following the burn.  TPP director Bob Hamilton had
agreed to call us the morning of the burn, but didn't actually call us
until this morning; the day following the burn.  Due to the short
notification and prior commitment of personnel, Site Ops will not be
able to travel to the site until Monday or Tuesday of next week.

John Shatz was given the following information about the duration of
the burn:

>Bob Hamilton called and indicated that they did a control burn of the
>Tall Grass Prairie yesterday(3-20-97).  He indicated that the fire in
>our area lasted between 4:55 PM to 5:40 PM.  He also said that they
>plan to put this control burning on a two to three year cycle.

Affect on ARM Data:

Review of the EBBR temperature data (the sensor in the lower position)
shows a dramatic increase of temperature from 26 to 37 Celsius in a 
10 minute period.  The temperatures appear to have been affected for 
approximately 1 hour. 

Analysis of the broadband shortwave albedo during this period reveals
changes that appear to be related to the burn. The following is 
a listing of the daily average shortwave albedos (caluclated by running a linear
regression fit on the "curve" created by plotting the upwelling shortwave 
vs. the downwelling shortwave values from the E12 SIROS broadband instrumentation):

    Date        Broadband Shortwave Albedo
    ________   ____________________________

    3-14-97              .171
    3-15-97              .171
    3-16-97              .169
    3-17-97              .166
    3-18-97              .135
    3-19-97              .171
    3-20-97              .174
    3-21-97              .141
    3-22-97              .143
    3-23-97              .148
    3-24-97              .147

The grass cutting activity at the EF does not appear to be responsible
for the abledo change on 3-18; this is likely related to the drizzle
and overcast sky conditions in the area on that day. Note that the albedo
recovers to previous values by the next day. 

The burn occured late on the 20th, and it appears the albedo after the
burn sustained a more long-lasting decrease in value.  Examination of
both the upwelling and downwelling solar irradiance indicates that 
the albedo change was a resultant of the decrease in upwelling irradiance,
as the downwelling values were comparable to other sites.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • North latitude(lat)
  • East longitude(lon)
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Altitude above mean sea level(alt)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D970703.3
Start DateStart TimeEnd DateEnd Time
03/15/1997224504/22/19971830
Subject:
SGP/EBBR/E15 - Connections Affecting Home Signals
DataStreams:sgp30ebbrE15.b1
Description:
For most of the period above at E15, Ringwood, OK, home signals were very
large, resulting in incorrect data.  On April 22, 1997, site operations found 
some loose connections on the J-panels that were causing the problem.  This
problem affected a wide range of measurements and calculated values, 
rendering much of the data, including the sensible and latent heat fluxes 
as incorrect.  Only careful examination of the data would allow some to be 
used as is and other quantities to be recalculated.  I would request that 
anyone needing this data contact me for information on it's quality.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • home_signal_30
  • Sensible heat flux(sensible_heat_flux)
  • home_signal_15


Back To Table of Contents

DQRID : D970730.2
Start DateStart TimeEnd DateEnd Time
06/03/1997120006/08/19971515
Subject:
SGP/EBBR/E12 - Wind Direction Sensor Malfunctions
DataStreams:sgp30ebbrE12.b1
Description:
For much of the period above, a malfunction in the E12 EBBR wind direction 
sensor (insect larvae shorting out the circuit board) caused incorrect 
values for 5 minute res_ws, wind_d, and sigma_wd, 15 minute mv_wind_d, and 
30 minute res_ws, wind_d, and sigma_wd.  Wind direction normally indicated 
north (near 0 or 360 degrees); there were some times during the period when 
wind directions looked good, but the lack of variation in direction and sigma 
implies that the data is suspect.  Therefore, it would be wise to flag all
of the values listed above during the entire time period as incorrect. 
The wind direction sensor (S/N 3081) was replaced with S/N 3042 at 1515 GMT 
on June 8, 1997.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D970730.3
Start DateStart TimeEnd DateEnd Time
07/17/1997093007/25/19971600
Subject:
SGP/EBBR/E13 - CR10 Malfunction
DataStreams:sgp30ebbrE13.b1
Description:
The CR10 apparently malfunctioned on 17 July 1997.  This caused a variety 
of effects, including incorrect datalogger clock times, missing data 
periods, and some corrupted data fields.  The CR10 was replaced on 
25 July 1997; all data fields are now correct.  Data users may contact
the mentor for more detailed information on data quality during this 
period.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D971021.4
Start DateStart TimeEnd DateEnd Time
04/10/1997165204/10/19971758
Subject:
SGP/EBBR/E12 - EBBR Biannual Checks
DataStreams:sgp30ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D971021.5
Start DateStart TimeEnd DateEnd Time
04/28/1997141904/28/19971445
Subject:
SGP/EBBR/E13 - EBBR Biannual Checks
DataStreams:sgp30ebbrE13.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D971021.6
Start DateStart TimeEnd DateEnd Time
04/22/1997152504/22/19971546
Subject:
SGP/EBBR/E15 - EBBR Biannual Checks
DataStreams:sgp30ebbrE15.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980117.14
Start DateStart TimeEnd DateEnd Time
12/21/1997044012/21/19971820
01/04/1998052501/05/19981830
01/09/1998215001/12/19980330
Subject:
SGP/EBBR/E15 - EBBR Frozen Wind Speed
DataStreams:sgp30ebbrE15.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980117.17
Start DateStart TimeEnd DateEnd Time
01/04/1998075001/04/19981900
01/08/1998070501/08/19981925
Subject:
SGP/EBBR/E12- EBBR Frozen Wind Speed
DataStreams:sgp30ebbrE12.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D980117.19
Start DateStart TimeEnd DateEnd Time
01/04/1998062501/05/19980115
Subject:
SGP/EBBR/E13- EBBR Frozen Wind Speed
DataStreams:sgp30ebbrE13.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D980117.24
Start DateStart TimeEnd DateEnd Time
01/04/1998063001/05/19981830
12/21/1997074512/21/19971715
Subject:
SGP/EBBR/E15 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp30ebbrE15.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980117.26
Start DateStart TimeEnd DateEnd Time
01/04/1998130001/15/19981715
Subject:
SGP/EBBR/E12 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp30ebbrE12.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:

Note:  Mentor supplied the end date/time for this DQR after submittal
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D980117.27
Start DateStart TimeEnd DateEnd Time
01/04/1998074501/16/19981600
Subject:
SGP/EBBR/E13 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp30ebbrE13.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:

Note: Mentor supplied the end date/time for this DQR after submittal
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D980117.29
Start DateStart TimeEnd DateEnd Time
12/16/1997160012/29/19971730
Subject:
SGP/EBBR/E15 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affected
DataStreams:sgp30ebbrE15.b1
Description:
The upper dome of the EBBR net radiometers was punctured.
After the puncture, water collected in the top and/or bottom dome.  The
water was removed and the dome was replaced during PM visits. 

 In some cases, the puncture and water resulted in incorrect data. 
Comparison with net radiation values from surrounding EBBR sites and the
SIRS is neccesary to determine if the EBBR net radiation data 
are correct or incorrect.

It is often difficult to tell from the data when the punctures occurred,
but they would have existed for no more than 2 weeks, since the domes
are checked during each two-weekly PM visit.

Incorrect net radiation data results in the latent heat flux and
sensible heat flux also being incorrect.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D980117.32
Start DateStart TimeEnd DateEnd Time
12/18/1997170012/31/19971615
Subject:
SGP/EBBR/E12 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affected
DataStreams:sgp30ebbrE12.b1
Description:
The upper dome of the EBBR net radiometers was punctured.
After the puncture, water collected in the top and/or bottom dome.  The
water was removed and the dome was replaced during PM visits. 

 In some cases, the puncture and water resulted in incorrect data. 
Comparison with net radiation values from surrounding EBBR sites and the
SIRS is neccesary to determine if the EBBR net radiation data 
are correct or incorrect.

It is often difficult to tell from the data when the punctures occurred,
but they would have existed for no more than 2 weeks, since the domes
are checked during each two-weekly PM visit.

Incorrect net radiation data results in the latent heat flux and
sensible heat flux also being incorrect.
Measurements:sgp30ebbrE12.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D980117.6
Start DateStart TimeEnd DateEnd Time
11/27/1997053012/18/19971805
Subject:
SGP/EBBR/E12 - AEM Failure and Replacement
DataStreams:sgp30ebbrE12.b1
Description:
The E12 AEM did not exchange for most of the period above, yielding small
negative home signals.  The AEM was replaced on 18 December by site
operations personnel.  All 30 minute e, h, and bowen data are incorrect for
the times when the home signal is incorrect, and the temperature, relative
humidity, and vapor pressures do not represent properly switched values.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • home_signal_30
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D980410.8
Start DateStart TimeEnd DateEnd Time
01/15/1998101501/15/19981445
Subject:
SGP/EBBR/E13 - Wind Speed Sensor Frozen
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was frozen during the period.  

Data values that were incorrect are:

 5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D980410.9
Start DateStart TimeEnd DateEnd Time
01/14/1998091501/14/19981920
Subject:
SGP/EBBR/E15 - Wind Speed Sensor Frozen
DataStreams:sgp30ebbrE15.b1
Description:
The wind speed sensor was frozen during the period.  

Data values that were incorrect are:

 5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980416.11
Start DateStart TimeEnd DateEnd Time
10/23/1997195510/23/19972015
Subject:
SGP/EBBR/E12 - 3-Month Check
DataStreams:sgp30ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D980416.12
Start DateStart TimeEnd DateEnd Time
10/10/1997185010/10/19971932
Subject:
SGP/EBBR/E13 - 3-Month Check
DataStreams:sgp30ebbrE13.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp30ebbrE13.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • temp_trh_bottom
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_top


Back To Table of Contents

DQRID : D980416.13
Start DateStart TimeEnd DateEnd Time
10/07/1997175010/07/19971832
Subject:
SGP/EBBR/E15 - 3-Month Check
DataStreams:sgp30ebbrE15.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980513.4
Start DateStart TimeEnd DateEnd Time
01/03/1998000004/21/19981515
Subject:
SGP/EBBR/E15 - Pressure Diurnal Fluctuations
DataStreams:sgp30ebbrE15.b1
Description:
During this period the barometric pressure exhibited increasingly larger,
and unatural, diurnal fluctuations.  This has been observed at other sites
previously.  The sensor was replaced on April 21.  The diurnal fluctuations
had only a minor effect on the calculated fluxes of latent and sensible
heat; the fluxes are not incorrect as a result of the problem.
Measurements:sgp30ebbrE15.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D980513.5
Start DateStart TimeEnd DateEnd Time
04/21/1998153004/28/19981530
Subject:
SGP/EBBR/E15 - Pressure Too High
DataStreams:sgp30ebbrE15.b1
Description:
During this period the barometric pressure was consistently much greater
than the true pressure, hanging around 113 kPa all of the time.
The defective sensor was replaced on April 28. The calculated fluxes of 
latent and sensible heat are incorrect during the period.
Measurements:sgp30ebbrE15.b1:
  • Atmospheric pressure(atmos_pressure)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D980513.6
Start DateStart TimeEnd DateEnd Time
02/12/1998093005/01/19981530
Subject:
SGP/EBBR/E15 - Left T/RH Probe Temperature Too Large
DataStreams:sgp30ebbrE15.b1
Description:
Beginning in February, the temperature of the left T/RH probe reported too
high a value at some times.  The frequency of the problem increased with
time until 28 April at 1520 GMT, when a defective probe was installed; the
latter probe temperature indicated very high values.  This continued until
1 May at 1530 GMT when a working probe was installed. Times of incorrect 
humidity probe temperatures can be determined by comparing 5 or 30 minute 
values of air temperature and humidity probe temperature; at these times the 
calculated bowen ratio, and the fluxes of latent and sensible heat are 
incorrect.

The incorrect variables were:

5  minute:  thum_top, thum_bot, vp_top, vp_bot
15 minute:  rr_thum_l
30 minute:  thum_top, thum_bot, vp_top, vp_bot, bowen, e, h
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980528.13
Start DateStart TimeEnd DateEnd Time
04/07/1998013005/21/19981830
Subject:
SGP/EBBR/E12 - Wind Direction Sensor Failure
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction sensor failed, producing zero values.  
The cause is unknown.  Data values affected are below:

 5 minute: res_ws, wind_d, sigma_wd

15 minute: mv_wind_d

30 Minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D980529.10
Start DateStart TimeEnd DateEnd Time
05/07/1998200005/07/19982030
Subject:
SGP/EBBR/E13 - Six Month Checks
DataStreams:sgp30ebbrE13.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period indicated.
Measurements:sgp30ebbrE13.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D980529.11
Start DateStart TimeEnd DateEnd Time
05/05/1998145905/05/19981530
Subject:
SGP/EBBR/E15 - Six Month Checks
DataStreams:sgp30ebbrE15.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period above.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980529.9
Start DateStart TimeEnd DateEnd Time
05/21/1998185505/21/19981918
Subject:
SGP/EBBR/E12 - Six Month Checks
DataStreams:sgp30ebbrE12.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period indicated.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D981112.5
Start DateStart TimeEnd DateEnd Time
10/02/1998034510/08/19981930
Subject:
SGP/EBBR/E13 - Net Radiation Incorrect - Water in Bottom Dome
DataStreams:sgp30ebbrE13.b1
Description:
Water entered the net radiometer top dome through a hole made, probably,
by migrating birds (this happens every Spring and Autumn) and accumulated
in the bottom dome.  This causes nighttime net radiations to be too large
and daytime net radiations to be too small.  The data is therefore incorrect.
Measurements:sgp30ebbrE13.b1:
  • Net radiation(net_radiation)


Back To Table of Contents

DQRID : D981113.3
Start DateStart TimeEnd DateEnd Time
11/05/1998120011/05/19981800
Subject:
SGP/EBBR/E15 - Aspirator loosened from AEM mount
DataStreams:sgp30ebbrE15.b1
Description:
The left aspirator was loosened from the AEM mount.  Thus all gradients
of T/RH/VP and sensible and latent heat fluxes for the period are 
incorrect.  T/RH/VP measurements from the left probe are incorrect only
through 1745 GMT.
Measurements:sgp30ebbrE15.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • bowen_ratio
  • temp_trh_bottom
  • temp_air_top
  • Sensible heat flux(sensible_heat_flux)
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D990127.21
Start DateStart TimeEnd DateEnd Time
12/21/1998024512/22/19981630
Subject:
SGP/EBBR/E12 - Wind Direction Data Incorrect (revised)
DataStreams:sgp30ebbrE12.b1
Description:
The wind direction sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D990127.26
Start DateStart TimeEnd DateEnd Time
01/08/1999000501/08/19990900
Subject:
SGP/EBBR/E15 - Wind Direction Data Incorrect (revised)
DataStreams:sgp30ebbrE15.b1
Description:
The wind direction sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE15.b1:
  • wdir_vec_std
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990127.32
Start DateStart TimeEnd DateEnd Time
01/01/1999151501/01/19992230
01/08/1999020501/08/19991600
12/21/1998001512/24/19981730
Subject:
SGP/EBBR/E13 - Wind Speed Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D990127.33
Start DateStart TimeEnd DateEnd Time
01/01/1999151501/01/19992230
Subject:
SGP/EBBR - EBBR E13 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D990127.34
Start DateStart TimeEnd DateEnd Time
01/08/1999020501/08/19991600
Subject:
SGP/EBBR - EBBR E13 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE13.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • home_signal_30
  • corr_soil_heat_flow_3
  • energy_storage_change_4
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • East longitude(lon)
  • temp_trh_top
  • base_time
  • soil_heat_flow_1
  • soil_moisture_1
  • soil_heat_flow_3
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_moisture_5
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_2
  • time_offset
  • Atmospheric pressure(atmos_pressure)
  • temp_reference
  • vapor_pressure_top
  • soil_heat_capacity_1
  • Soil temperature mean 2(soil_temp_2)
  • soil_heat_capacity_5
  • Soil temperature mean 1(soil_temp_1)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • home_signal_15
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • bowen_ratio
  • surface_soil_heat_flux_3
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_2
  • rh_bottom_fraction
  • North latitude(lat)
  • vapor_pressure_bottom
  • Net radiation(net_radiation)
  • temp_trh_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D990127.44
Start DateStart TimeEnd DateEnd Time
12/20/1998213512/25/19981730
01/01/1999162001/02/19992000
01/07/1999221501/09/19990130
Subject:
SGP/EBBR/E15 - Wind Speed Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE15.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990127.45
Start DateStart TimeEnd DateEnd Time
01/01/1999162001/02/19992000
Subject:
SGP/EBBR - EBBR E15 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D990127.46
Start DateStart TimeEnd DateEnd Time
01/07/1999221501/09/19990130
Subject:
SGP/EBBR - EBBR E15 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE15.b1:
  • East longitude(lon)
  • vapor_pressure_top
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • temp_trh_top
  • surface_soil_heat_flux_3
  • Atmospheric pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • home_signal_15
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • temp_air_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Net radiation(net_radiation)
  • soil_heat_flow_1
  • soil_moisture_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_flow_3
  • soil_heat_capacity_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_flow_4
  • soil_moisture_4
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • North latitude(lat)
  • Latent heat flux(latent_heat_flux)
  • soil_heat_capacity_4
  • home_signal_30
  • soil_heat_capacity_5
  • temp_trh_bottom
  • time_offset
  • base_time
  • Altitude above mean sea level(alt)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Wind direction vector mean(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • temp_reference
  • rh_top_fraction
  • energy_storage_change_1
  • wdir_vec_std
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4


Back To Table of Contents

DQRID : D990128.1
Start DateStart TimeEnd DateEnd Time
01/01/1999170001/03/19991130
12/20/1998233512/22/19981630
01/07/1999180501/09/19990330
Subject:
SGP/EBBR/E12 - Wind Speed Data Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D990128.2
Start DateStart TimeEnd DateEnd Time
01/07/1999180501/09/19990330
Subject:
SGP/EBBR - EBBR E12 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • North latitude(lat)
  • East longitude(lon)
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Altitude above mean sea level(alt)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D990129.1
Start DateStart TimeEnd DateEnd Time
01/01/1999170001/03/19991130
Subject:
SGP/EBBR - EBBR E12 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • North latitude(lat)
  • East longitude(lon)
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Altitude above mean sea level(alt)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D990129.2
Start DateStart TimeEnd DateEnd Time
12/28/1998160012/28/19981630
Subject:
SGP/EBBR/E12 - Data Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Most of the data values for just this time (1630 GMT) for the 5, 15, and 30
minute periods are incorrect; this apparently was the result of PM activities.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • North latitude(lat)
  • East longitude(lon)
  • Net radiation(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • vapor_pressure_top
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Altitude above mean sea level(alt)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • corr_soil_heat_flow_1
  • bowen_ratio
  • Soil temperature mean 5(soil_temp_5)
  • corr_soil_heat_flow_2
  • Soil temperature mean 4(soil_temp_4)
  • corr_soil_heat_flow_3
  • Soil temperature mean 3(soil_temp_3)
  • corr_soil_heat_flow_4
  • Wind direction vector mean(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • Atmospheric pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D990129.3
Start DateStart TimeEnd DateEnd Time
12/28/1998134512/28/19981730
Subject:
SGP/EBBR/E12 - Temperature, RH, and Vapor Pressure Data Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The right aspirator housing fell off of the AEM around 1345 GMT, by looking
at the data.  The housing was put back into place later in the day during 
a PM visit.  The following values were affected:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top,
           vp_bot
15 minute: rr_thum_r, mv_hum_r, tair_r
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top,
           vp_bot, bowen, e, h
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • rh_bottom_fraction
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_trh_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_trh_top


Back To Table of Contents

DQRID : D990129.4
Start DateStart TimeEnd DateEnd Time
11/24/1998131511/24/19981530
Subject:
SGP/EBBR/E12 - All Temperature Measurements Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Failure of the multiplexer connection for the reference temperature 
thermocouple in the control box or a problem with the Campbell CR10
bridge circuitry caused all air and soil temperature measurements
to be incorrect. Therefore, the computed 30 minute bowen, e, and h were 
also incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 4(soil_temp_4)
  • temp_reference
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Latent heat flux(latent_heat_flux)
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D990311.1
Start DateStart TimeEnd DateEnd Time
02/02/1999040002/23/19991500
Subject:
SGP/EBBR/E15 - Temperatures Incorrect
DataStreams:sgp30ebbrE15.b1
Description:
Poor contact of the reference temperature probe leads to the J-panel or
multiplexer caused frequent offscale and incorrect values of the reference
temperature.  All other temperature measurements (air, soil, and humidity 
probe) depend on the reference temperature for a correction.  Therefore all
temperature measurements are frequently offscale and incorrect during the 
specified period.  The data clearly shows the offscale times.
Measurements:sgp30ebbrE15.b1:
  • temp_trh_top
  • temp_reference
  • temp_air_bottom
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • temp_trh_bottom
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 3(soil_temp_3)
  • temp_air_top


Back To Table of Contents

DQRID : D990415.1
Start DateStart TimeEnd DateEnd Time
03/13/1999233003/14/19990500
Subject:
SGP/EBBR/E13 - Wind Speed Frozen
DataStreams:sgp30ebbrE13.b1
Description:
Wind speed and residual wind speed during this period 
are incorrect caused by an ice storm.
Measurements:sgp30ebbrE13.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D990622.4
Start DateStart TimeEnd DateEnd Time
06/04/1999163006/04/19991700
Subject:
SGP/EBBR/E12 - RH top Data Zero
DataStreams:sgp30ebbrE12.b1
Description:
The one data value hum_top was incorrect in the 30 minute data.  5 and 15
minute data were not affected, and the 30 minute flux data was not affected.
The data value may have been lost in remote data retrieval, resulting in
a zero value instead.
Measurements:sgp30ebbrE12.b1:
  • rh_top_fraction


Back To Table of Contents



END OF DATA