DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D140228.2 | MAO/SONDE/M1 - Temperature Sensor Failure | maosondewnpnM1.b1 | Incorrect |
D140821.2 | TWP/MERGESONDE/C2 - Reprocess: Suspect rh_scaled values | twpmergesonde1maceC2.c1 | Suspect |
D140822.13 | NIM/MERGESONDE/M1 - Suspect rh_scaled values | nimmergesonde2maceM1.c1 | Suspect |
D141111.4 | MAO/SONDE/M1 - Reprocessing Notice (RID 1253) | maosondewnpnM1.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/26/2014 | 2330 | 02/26/2014 | 2330 | Incorrect |
Subject: | MAO/SONDE/M1 - Temperature Sensor Failure |
DataStreams: | maosondewnpnM1.b1 |
Description: | It appears that the temperature sensor failed on release of balloon |
Measurements: | maosondewnpnM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/01/2002 | 0000 | 12/30/2010 | 2359 | Suspect |
Subject: | TWP/MERGESONDE/C2 - Reprocess: Suspect rh_scaled values |
DataStreams: | twpmergesonde1maceC2.c1 |
Description: | MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the relative humidity profiles provided by the rh_scaled field. In addition, this bad input data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem appears to typically occur when there is moisture impacting the microwave radiometer causing large spikes in brightness temperatures. During these periods the rh_scaled values are often saturated at 101% for much of the profile. |
Measurements: | twpmergesonde1maceC2.c1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/10/2006 | 0000 | 01/07/2007 | 2359 | Suspect |
Subject: | NIM/MERGESONDE/M1 - Suspect rh_scaled values |
DataStreams: | nimmergesonde2maceM1.c1 |
Description: | MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the relative humidity profiles provided by the rh_scaled field. In addition, this bad input data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem appears to typically occur when there is moisture impacting the microwave radiometer causing large spikes in brightness temperatures. During these periods the rh_scaled values are often saturated at 101% for much of the profile. A new version of the MERGESONDE VAP has corrected this problem, and these data will eventually be corrected by a reprocessing task. |
Measurements: | nimmergesonde2maceM1.c1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/17/2014 | 0528 | 10/17/2014 | 0718 | Does not affect quality |
Subject: | MAO/SONDE/M1 - Reprocessing Notice (RID 1253) |
DataStreams: | maosondewnpnM1.b1 |
Description: | See below for details of reprocessing that was completed on 20150121. Original DQR category: 4(Red, Incorrect) ------------------------------------------------------------------------------- The operator incorrectly entered the surface RH value as 10% when it was actually 100%. |
Measurements: | maosondewnpnM1.b1:
|