DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D021206.1 | TWP/SONDE/C2 - Broken Temperature Sensor | twpsondewnpnC2.b1 | Incorrect |
D030419.1 | TWP/SONDE/C2 - Bad RH Data (AIRS Validation Sonde) | twpsondewnpnC2.b1 | Incorrect |
D030608.4 | TWP/SONDE/C2 - Failure of RH sensor | twpsondewnpnC2.b1 | Suspect |
D031008.1 | TWP/SONDE/C2 - Strange problem with data - | twpsondewnpnC2.b1 | Incorrect |
D031231.1 | TWP/SONDE/C2 - RH sensor bad | twpsondewnpnC2.b1 | Suspect |
D040127.3 | TWP/SONDE/C2 - Broken temperature sensors | twpsondewnpnC2.b1 | Incorrect |
D040208.2 | TWP/SONDE/C2 - Questionable rH data | twpsondewnpnC2.b1 | Suspect |
D040219.4 | TWP/SONDE/C2 - Bad RH sensor | twpsondewnpnC2.b1 | Suspect |
D040425.1 | TWP/SONDE/C2 - Bad RH values aloft | twpsondewnpnC2.b1 | Incorrect |
D040711.2 | TWP/SONDE/C2 - RH sensor failure near surface | twpsondewnpnC2.b1 | Suspect |
D040815.1 | TWP/SONDE/C2 - Operator used wrong calibration tape | twpsondewnpnC2.b1 | Incorrect |
D040921.1 | TWP/SONDE/C2 - RH sensor failure below 9km | twpsondewnpnC2.b1 | Suspect |
D040921.2 | TWP/SONDE/C2 - Bad RH values aloft | twpsondewnpnC2.b1 | Incorrect |
D050913.3 | TWP/SONDE/C2 - Bad RH sensor | twpsondewnpnC2.b1 | Suspect |
D051122.2 | TWP/SONDE/C2 - Broken temperature sensor | twpsondewnpnC2.b1 | Incorrect |
D051219.2 | TWP/SONDE/C2 - Broken temperature sensor | twpsondewnpnC2.b1 | Incorrect |
D070920.2 | TWP/SONDE/C2 - Failure of RH sensor | twpsondewnpnC2.b1 | Suspect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/11/2003 | 2345 | 06/12/2003 | 0112 | Incorrect |
04/24/2003 | 2358 | 04/25/2003 | 0126 | Incorrect |
12/24/2002 | 2331 | 12/25/2002 | 0112 | Incorrect |
06/02/2003 | 1134 | 06/02/2003 | 1321 | Incorrect |
11/25/2002 | 2337 | 11/26/2002 | 0001 | Incorrect |
09/27/2003 | 2327 | 09/28/2003 | 0132 | Incorrect |
06/06/2003 | 2335 | 06/07/2003 | 0057 | Incorrect |
06/26/2003 | 2335 | 06/27/2003 | 0114 | Incorrect |
04/23/2003 | 1129 | 04/23/2003 | 1308 | Incorrect |
09/18/2002 | 1137 | 09/18/2002 | 1301 | Incorrect |
12/16/2002 | 1138 | 12/16/2002 | 1248 | Incorrect |
06/09/2003 | 2340 | 06/10/2003 | 0116 | Incorrect |
04/22/2003 | 2341 | 04/23/2003 | 0122 | Incorrect |
11/23/2002 | 2330 | 11/24/2002 | 0108 | Incorrect |
12/27/2002 | 2344 | 12/28/2002 | 0131 | Incorrect |
09/24/2002 | 0129 | 09/24/2002 | 0204 | Incorrect |
12/22/2002 | 0136 | 12/22/2002 | 0204 | Incorrect |
06/14/2003 | 1133 | 06/14/2003 | 1300 | Incorrect |
03/28/2003 | 0214 | 03/28/2003 | 0339 | Incorrect |
09/24/2002 | 0220 | 09/24/2002 | 0352 | Incorrect |
Subject: | TWP/SONDE/C2 - Broken Temperature Sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensors on these radiosondes broke at launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/13/2003 | 0124 | 04/13/2003 | 0200 | Incorrect |
Subject: | TWP/SONDE/C2 - Bad RH Data (AIRS Validation Sonde) |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The RH sensor heating circuit failed on this sonde. This results in oscillation of reported RH between reasonable values and values near zero. This was an AIRS validation sounding. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/03/2003 | 2339 | 06/04/2003 | 0016 | Suspect |
Subject: | TWP/SONDE/C2 - Failure of RH sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/02/2003 | 0232 | 10/02/2003 | 0300 | Incorrect |
Subject: | TWP/SONDE/C2 - Strange problem with data - |
DataStreams: | twpsondewnpnC2.b1 |
Description: | This is very strange. The data has what appears to be a pressure jump at launch (from 1007.2 to 956.5 hPa) but the sounding temperature and RH data clearly look to be interpolated between the surface and tropopause. By examining the absolutely raw data, I found that the system assigned an elapsed time of 408 seconds (since system start up) to the launch point, but there is no raw data between 410 and 532 seconds. The raw pressure value at 410 seconds is 1007.6 hPa and that at 532 seconds is 40.9 hPa! Unless this sounding was done by using a rocket-powered balloon (maybe even then), it would be impossible for the sonde to get to 40.9 hPa in 2 minutes. Because the apparent gap is only two minutes, the system was able to interpolate but is not sophisticated enough to understand that the limits of the interpolation are unreasonable. I can't imagine what went wrong - I've not seen anything like this before. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/22/2003 | 0025 | 10/22/2003 | 0155 | Suspect |
10/22/2003 | 2340 | 10/23/2003 | 0121 | Suspect |
Subject: | TWP/SONDE/C2 - RH sensor bad |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuits failed during these soundings. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/29/2004 | 2332 | 03/30/2004 | 0047 | Incorrect |
05/13/2004 | 2334 | 05/14/2004 | 0112 | Incorrect |
01/19/2004 | 0223 | 01/19/2004 | 0346 | Incorrect |
11/18/2003 | 1205 | 11/18/2003 | 1340 | Incorrect |
12/23/2003 | 2342 | 12/24/2003 | 0132 | Incorrect |
12/21/2003 | 1155 | 12/21/2003 | 1344 | Incorrect |
05/14/2004 | 1406 | 05/14/2004 | 1411 | Incorrect |
01/18/2004 | 1135 | 01/18/2004 | 1256 | Incorrect |
03/09/2004 | 1145 | 03/09/2004 | 1315 | Incorrect |
12/20/2003 | 1225 | 12/20/2003 | 1408 | Incorrect |
02/26/2004 | 1221 | 02/26/2004 | 1350 | Incorrect |
12/23/2003 | 1137 | 12/23/2003 | 1259 | Incorrect |
06/07/2004 | 0224 | 06/07/2004 | 0351 | Incorrect |
11/19/2003 | 1156 | 11/19/2003 | 1346 | Incorrect |
06/25/2004 | 1146 | 06/25/2004 | 1328 | Incorrect |
11/08/2003 | 2335 | 11/09/2003 | 0215 | Incorrect |
07/02/2004 | 0059 | 07/02/2004 | 0217 | Incorrect |
01/16/2004 | 2337 | 01/17/2004 | 0109 | Incorrect |
01/09/2004 | 1157 | 01/09/2004 | 1342 | Incorrect |
12/21/2003 | 0056 | 12/21/2003 | 0126 | Incorrect |
09/08/2004 | 1425 | 09/08/2004 | 1605 | Incorrect |
02/17/2004 | 1406 | 02/17/2004 | 1536 | Incorrect |
01/12/2004 | 2342 | 01/13/2004 | 0214 | Incorrect |
10/18/2004 | 2346 | 10/19/2004 | 0128 | Incorrect |
03/30/2004 | 2334 | 03/31/2004 | 0059 | Incorrect |
01/08/2004 | 1135 | 01/08/2004 | 1309 | Incorrect |
01/26/2004 | 1202 | 01/26/2004 | 0146 | Incorrect |
12/08/2004 | 1143 | 12/08/2004 | 1306 | Incorrect |
03/22/2004 | 1134 | 03/22/2004 | 1300 | Incorrect |
01/23/2004 | 1137 | 01/23/2004 | 1319 | Incorrect |
11/21/2003 | 0044 | 11/21/2003 | 0113 | Incorrect |
11/29/2004 | 2321 | 11/30/2004 | 0105 | Incorrect |
01/19/2004 | 2329 | 01/20/2004 | 0157 | Incorrect |
10/13/2003 | 0040 | 10/13/2003 | 0203 | Incorrect |
03/14/2004 | 1131 | 03/14/2004 | 1300 | Incorrect |
05/01/2004 | 2335 | 05/02/2004 | 0110 | Incorrect |
12/30/2004 | 1130 | 12/30/2004 | 1239 | Incorrect |
07/24/2004 | 1235 | 07/24/2004 | 1355 | Incorrect |
09/08/2004 | 2338 | 09/08/2004 | 2345 | Incorrect |
01/16/2004 | 1409 | 01/16/2004 | 1548 | Incorrect |
08/22/2004 | 1144 | 08/22/2004 | 1207 | Incorrect |
04/11/2004 | 2348 | 04/12/2004 | 0120 | Incorrect |
01/22/2004 | 0052 | 01/22/2004 | 0227 | Incorrect |
07/20/2004 | 0220 | 07/20/2004 | 0358 | Incorrect |
12/23/2003 | 0042 | 12/23/2003 | 0212 | Incorrect |
05/02/2004 | 2336 | 05/03/2004 | 0109 | Incorrect |
01/21/2004 | 1252 | 01/21/2004 | 1400 | Incorrect |
01/09/2004 | 1359 | 01/09/2004 | 1537 | Incorrect |
Subject: | TWP/SONDE/C2 - Broken temperature sensors |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensors on these radiosondes broke after launch. All temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/04/2004 | 1147 | 02/04/2004 | 1337 | Suspect |
Subject: | TWP/SONDE/C2 - Questionable rH data |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/18/2004 | 0035 | 02/18/2004 | 0205 | Suspect |
Subject: | TWP/SONDE/C2 - Bad RH sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/21/2004 | 1232 | 04/21/2004 | 1248 | Incorrect |
Subject: | TWP/SONDE/C2 - Bad RH values aloft |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit on this sonde failed about 24 minutes into the flight. The RH values look reasonable, though somewhat noisy, from the surface to approximately 6.9 km (439 hPa) at which point they begin to oscillate between 0 and 100 %. This behavior stops when the sonde reaches approximately 11.5km (232 hPa) when the air temperature drops below -40 degC. The oscillation stops at that point, though the RH remains higher than might be expected even under supersaturated conditions. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/10/2004 | 1238 | 07/10/2004 | 1315 | Suspect |
Subject: | TWP/SONDE/C2 - RH sensor failure near surface |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/12/2004 | 0044 | 08/12/2004 | 0233 | Incorrect |
Subject: | TWP/SONDE/C2 - Operator used wrong calibration tape |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears as though the opperator used the wrong calibration tape for this sounding. The primary symptom is a jump in temperature from a surface value of 30.1 degC to the first value aloft of 61.0 degC. Secondly, the recorded serial number for this sounding is Z1430179 which is the same serial number recorded for the previous sounding. This problem points to three failures of procedure (I have notified TWP site ops by e-mail). The first failure is using the wrong tape. The second failure is not checking the radiosonde values before launch which relates to the third failure of not entering the radiosonde values as the surface values of the sounding. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/16/2004 | 1135 | 09/16/2004 | 1210 | Suspect |
Subject: | TWP/SONDE/C2 - RH sensor failure below 9km |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/19/2004 | 1408 | 09/19/2004 | 1447 | Incorrect |
09/18/2004 | 0058 | 09/18/2004 | 0133 | Incorrect |
09/17/2004 | 1145 | 09/17/2004 | 1216 | Incorrect |
Subject: | TWP/SONDE/C2 - Bad RH values aloft |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit on these sondes failed after launch but resume proper operation when the ambient temperature dropped below ~40 degC. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/03/2005 | 2350 | 07/04/2005 | 0024 | Suspect |
07/19/2005 | 2332 | 07/20/2005 | 0016 | Suspect |
07/10/2005 | 2340 | 07/11/2005 | 0021 | Suspect |
Subject: | TWP/SONDE/C2 - Bad RH sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below -50 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/21/2005 | 2332 | 11/22/2005 | 0140 | Incorrect |
11/19/2005 | 2334 | 11/20/2005 | 0153 | Incorrect |
Subject: | TWP/SONDE/C2 - Broken temperature sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/07/2005 | 1153 | 12/07/2005 | 1323 | Incorrect |
Subject: | TWP/SONDE/C2 - Broken temperature sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/19/2003 | 1221 | 03/19/2003 | 1253 | Suspect |
08/20/2003 | 2340 | 08/21/2003 | 0002 | Suspect |
Subject: | TWP/SONDE/C2 - Failure of RH sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The RH sensor ASIC that controls the sensor heating failed. As a result the RH at the beginning of the sounding oscillates between near-zero and ambient values. The RH heating cycle stops when the ambient temperature reaches below -30 degC; above this level RH values should be valid. |
Measurements: | twpsondewnpnC2.b1:
|