DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D160525.1 | ASI/MET/M1 - Damaged cable | asimetM1.b1 | Incorrect |
D160526.4 | ASI/TSI/M1 - Reprocess: Serial number incorrect | asitsiskycoverM1.b1 | Does not affect quality |
D160526.5 | ASI/MET/M1 - Site setup | asimetM1.b1 | Incorrect |
D160526.6 | ASI/MET/M1 - Broken wire | asimetM1.b1 | Incorrect |
D160526.7 | ASI/MET/M1 - Temp/Humidity sensor not at standard height | asimetM1.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/23/2016 | 2313 | 05/25/2016 | 1106 | Incorrect |
Subject: | ASI/MET/M1 - Damaged cable |
DataStreams: | asimetM1.b1 |
Description: | Damage to the temp/humidity instrument cable caused incorrect readings during this time. |
Measurements: | asimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/01/2016 | 0000 | 05/26/2016 | 1753 | Does not affect quality |
Subject: | ASI/TSI/M1 - Reprocess: Serial number incorrect |
DataStreams: | asitsiskycoverM1.b1 |
Description: | The serial number is incorrect. The correct serial number for this period is 103A. |
Measurements: | asitsiskycoverM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/23/2016 | 0000 | 04/26/2016 | 0931 | Incorrect |
Subject: | ASI/MET/M1 - Site setup |
DataStreams: | asimetM1.b1 |
Description: | Instruments were not yet aligned or in their permanent locations. Data during this time should not be used. |
Measurements: | asimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/26/2016 | 0931 | 05/10/2016 | 1612 | Incorrect |
Subject: | ASI/MET/M1 - Broken wire |
DataStreams: | asimetM1.b1 |
Description: | A wire on the sensor cable broke during this time and data are incorrect. |
Measurements: | asimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/26/2016 | 0931 | 05/25/2016 | 1100 | Does not affect quality |
Subject: | ASI/MET/M1 - Temp/Humidity sensor not at standard height |
DataStreams: | asimetM1.b1 |
Description: | Prior to 5/25, the temp/humidity sensor was mounted at 3 meters. On 5/25 the sensor was lowered to the standard height of 2 meters. No significant impact on data is expected. |
Measurements: | asimetM1.b1:
|