Data Quality Reports for Session: 179818 User: vghate Completed: 09/19/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D140228.2MAO/SONDE/M1 - Temperature Sensor FailuremaosondewnpnM1.b1Incorrect
D141111.4MAO/SONDE/M1 - Reprocessing Notice (RID 1253)maosondewnpnM1.b1Does not affect quality


DQRID : D140228.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/26/2014233002/26/20142330Incorrect
Subject:
MAO/SONDE/M1 - Temperature Sensor Failure
DataStreams:maosondewnpnM1.b1
Description:
It appears that the temperature sensor failed on release of balloon
Measurements:maosondewnpnM1.b1:
  • Dry Bulb Temperature(tdry)
  • Temperature, dewpoint, at altitude(dp)


Back To Table of Contents

DQRID : D141111.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/17/2014052810/17/20140718Does not affect quality
Subject:
MAO/SONDE/M1 - Reprocessing Notice (RID 1253)
DataStreams:maosondewnpnM1.b1
Description:
See below for details of reprocessing that was completed on 20150121. Original DQR 
category: 4(Red, Incorrect)

-------------------------------------------------------------------------------

The operator incorrectly entered the surface RH value as 10% when it was actually 100%.
Measurements:maosondewnpnM1.b1:
  • Temperature, dewpoint, at altitude(dp)
  • Humidity, relative, on hybrid-b grid, derived from RUC model(rh)


Back To Table of Contents



END OF DATA