DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D120128.1 | SGP/SEBS/E31 - Intermittent missing data | sgpsebsE31.b1 | Missing |
D140715.1 | SGP/SEBS/E31 - Surface Energy Balance Incorrect | sgpsebsE31.b1 | Incorrect |
D140821.8 | SGP/SEBS/E31 - Soil surface energy balance incorrect | sgpsebsE31.b1 | Incorrect |
D150530.4 | SGP/SEBS/E31 - All Data Missing | sgpsebsE31.b1 | Missing |
D150707.1 | SGP/SEBS/E31 - Soil Moisture 2 Measurement Spiked At Times | sgpsebsE31.b1 | Suspect |
D150825.1 | SGP/SEBS/E31 - Surface Energy Balance Incorrect | sgpsebsE31.b1 | Incorrect |
D150921.6 | SGP/SEBS/E31 - Reprocessed and Corrected:Net Radiation Measurements Incorrect | sgpsebsE31.b1 | Does not affect quality |
D151113.5 | SGP/SEBS/E31 - Surface Energy Balance Incorrect | sgpsebsE31.b1 | Suspect |
D151201.2 | SGP ALL INSTRUMENTS - Icing Event | sgpsebsE31.b1 | Does not affect quality |
D151207.4 | SGP/SEBS/E31 - Surface Energy Balance Incorrect | sgpsebsE31.b1 | Incorrect |
D160104.7 | SGP Site Power Outage Due to Winter Storm | sgpsebsE31.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/03/2011 | 1730 | 01/26/2012 | 1700 | Missing |
Subject: | SGP/SEBS/E31 - Intermittent missing data |
DataStreams: | sgpsebsE31.b1 |
Description: | A partial short in the 12V DC supply cable caused missing data every day, primarily during nighttime. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/27/2014 | 0000 | 07/01/2014 | 1530 | Incorrect |
Subject: | SGP/SEBS/E31 - Surface Energy Balance Incorrect |
DataStreams: | sgpsebsE31.b1 |
Description: | Soil heat flows 2 and 3 are incorrect, thus surface energy balance is incorrect. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/18/2014 | 0000 | 08/07/2014 | 0230 | Incorrect |
Subject: | SGP/SEBS/E31 - Soil surface energy balance incorrect |
DataStreams: | sgpsebsE31.b1 |
Description: | The failure of soil heat flow caused soil surface energy balance to be incorrect. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/16/2015 | 1930 | 05/20/2015 | 1830 | Missing |
Subject: | SGP/SEBS/E31 - All Data Missing |
DataStreams: | sgpsebsE31.b1 |
Description: | All data missing. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/11/2015 | 0130 | 06/21/2015 | 0900 | Suspect |
Subject: | SGP/SEBS/E31 - Soil Moisture 2 Measurement Spiked At Times |
DataStreams: | sgpsebsE31.b1 |
Description: | Soil Moisture 2 spiked at times, but had little to no effect on the calculated surface energy balance. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/09/2015 | 1500 | 08/12/2015 | 1800 | Incorrect |
Subject: | SGP/SEBS/E31 - Surface Energy Balance Incorrect |
DataStreams: | sgpsebsE31.b1 |
Description: | Surface energy balance was incorrect because soil temperature 2 was incorrect. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/03/2011 | 0000 | 05/20/2015 | 1800 | Does not affect quality |
Subject: | SGP/SEBS/E31 - Reprocessed and Corrected:Net Radiation Measurements Incorrect |
DataStreams: | sgpsebsE31.b1 |
Description: | DATA REPROCESSED and CORRECTED: The net radiation measurements were incorrect because the data logger program used the wrong calibration coefficients. The raw data were modified to recalculate the calibration coefficients and the SEBS data were reprocessed. The data were archived in May 2016. Please retrieve the reprocessed data for use in your analysis. ORIGINAL DQR CATEGORY: Red( Incorrect) REPROCESSED and CORRECTED DATA ARCHIVED:2016-05-17 REPROCESS IDENTIFICATION NUMBER: RID 1389 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- Net radiation measurements incorrect because the data logger program used the wrong calibration coefficients. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/22/2015 | 0200 | 11/05/2015 | 1730 | Suspect |
Subject: | SGP/SEBS/E31 - Surface Energy Balance Incorrect |
DataStreams: | sgpsebsE31.b1 |
Description: | Surface energy balance was often incorrect when soil temperature and moisture 3 were incorrect. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/27/2015 | 0000 | 11/30/2015 | 2359 | Does not affect quality |
Subject: | SGP ALL INSTRUMENTS - Icing Event |
DataStreams: | sgpsebsE31.b1 |
Description: | An icing event (winter storm Cara) passed slowly through the area during this time frame. Instruments at the SGP may have been affected by ice accumulation. |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/02/2015 | 0000 | 11/05/2015 | 1730 | Incorrect |
Subject: | SGP/SEBS/E31 - Surface Energy Balance Incorrect |
DataStreams: | sgpsebsE31.b1 |
Description: | Surface Energy Balance was incorrect during this period because of erratic soil moisture 2 measurements (which also affected soil heat flow 2). |
Measurements: | sgpsebsE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/26/2015 | 0000 | 01/01/2016 | 2359 | Does not affect quality |
Subject: | SGP Site Power Outage Due to Winter Storm |
DataStreams: | sgpsebsE31.b1 |
Description: | On Saturday and Sunday, December 26 and 27th a powerful winter storm (Goliath) brought sleet and freezing rain to much of Oklahoma with wind gusts of 45 MPH at times. The result was very very slick roads and mass power outages. The SGP central facility lost power at 8:55 PM CDT on Sunday, December 27th. The power was restored on 7:56 PM CDT on Wednesday, December 30th Site Emergency procedures were activated and Technicians drained water out of instrument reservoirs and other measures as needed, early Monday morning. On Wednesdays as roads and power started was restored to much of the areas east of I-35 , Site Technicians performed maintenance on several Extended Facilities. During this period, data are potentially missing, incorrect, or suspect. Carefully inspect the data before use. |
Measurements: | sgpsebsE31.b1:
|