DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D140919.1 | OLI/MET/M1 - Instrument problem | olimetM1.b1 | Suspect |
D150123.5 | OLI/MET/M1 - Power Outage | olimetM1.b1 | Missing |
D151102.5 | OLI/MET/M1 - Noisy (and missing) CMH data | olimetM1.b1 | Incorrect |
D151111.10 | OLI/MET/M1 - Chilled mirror hygrometer data spikes due to generator maintenance | olimetM1.b1 | Incorrect |
D151111.11 | OLI/MET/M1 - Wind data missing following generator maintenance | olimetM1.b1 | Missing |
D151111.9 | OLI/MET/M1 - Present weather detector backscatter warning | olimetM1.b1 | Does not affect quality |
D151218.14 | OLI/MET/M1 - Intermittent wind data loss | olimetM1.b1 | Does not affect quality |
D160524.1 | OLI/MET/M1 - Tower maintenance | olimetM1.b1 | Incorrect |
D160614.7 | OLI/MET/M1 - Wind sensor communication failure | olimetM1.b1 | Missing |
D160708.13 | OLI/MET/M1 - Missing wind data | olimetM1.b1 | Missing |
D160711.2 | OLI/MET/M1 - Missing wind data | olimetM1.b1 | Missing |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/08/2014 | 2016 | 09/09/2014 | 1053 | Suspect |
Subject: | OLI/MET/M1 - Instrument problem |
DataStreams: | olimetM1.b1 |
Description: | The chilled mirror dew point, vapor pressure, and relative humidity data fall out of agreement with co-located sensors during this time. After an instrument self-check, the problem was resolved. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/02/2015 | 2127 | 01/08/2015 | 1800 | Missing |
Subject: | OLI/MET/M1 - Power Outage |
DataStreams: | olimetM1.b1 |
Description: | No data are available for the selected time range due to a prolonged power outage. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/09/2015 | 1029 | 10/22/2015 | 0000 | Incorrect |
Subject: | OLI/MET/M1 - Noisy (and missing) CMH data |
DataStreams: | olimetM1.b1 |
Description: | The chilled mirror hygrometer data became noisy after self-checks during this period. Data are missing between 10/16 and 10/21 for service and calibration checks. The instrument was returned to service following calibration checks and minor connection repairs. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/08/2015 | 2005 | 11/08/2015 | 2008 | Incorrect |
11/08/2015 | 2234 | 11/08/2015 | 2238 | Incorrect |
Subject: | OLI/MET/M1 - Chilled mirror hygrometer data spikes due to generator maintenance |
DataStreams: | olimetM1.b1 |
Description: | During this time, the chilled mirror hygrometer data spiked due to power generator maintenance. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/08/2015 | 2347 | 11/09/2015 | 1853 | Missing |
Subject: | OLI/MET/M1 - Wind data missing following generator maintenance |
DataStreams: | olimetM1.b1 |
Description: | Following generator maintenance, the wind sensor stopped reporting wind data. Communication was reestablished following a configuration check. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/01/2015 | 1818 | 11/09/2015 | 1856 | Does not affect quality |
Subject: | OLI/MET/M1 - Present weather detector backscatter warning |
DataStreams: | olimetM1.b1 |
Description: | During this time, the present weather detector intermittently indicated a backscatter warning. A routine lens cleaning eliminated the backscatter. Data do not appear to be affected. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/13/2015 | 1840 | 05/11/2016 | 2106 | Does not affect quality |
Subject: | OLI/MET/M1 - Intermittent wind data loss |
DataStreams: | olimetM1.b1 |
Description: | Occasionally the wind speed data are missing and wind direction data drop to 0 due to an ongoing sensor circuitry problem. Only invalid data are missing. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/10/2016 | 2249 | 05/11/2016 | 2106 | Incorrect |
Subject: | OLI/MET/M1 - Tower maintenance |
DataStreams: | olimetM1.b1 |
Description: | Scheduled tower maintenance caused incorrect or missing data during this time. All data except for atmospheric pressure and data logger diagnostics should not be used. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/07/2016 | 2154 | 06/11/2016 | 2304 | Missing |
Subject: | OLI/MET/M1 - Wind sensor communication failure |
DataStreams: | olimetM1.b1 |
Description: | Folllowing a power outage, wind sensor communications failed resulting in missing data. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/17/2016 | 1552 | 07/08/2016 | 1842 | Missing |
Subject: | OLI/MET/M1 - Missing wind data |
DataStreams: | olimetM1.b1 |
Description: | Wind sensor lost its communication settings, resulting in missing data during this time. |
Measurements: | olimetM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/10/2016 | 2227 | 07/11/2016 | 1549 | Missing |
Subject: | OLI/MET/M1 - Missing wind data |
DataStreams: | olimetM1.b1 |
Description: | A power interruption resulted in missing wind data during this time. |
Measurements: | olimetM1.b1:
|