DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D120913.3 | NSA/CPC/X1 - Global metadata error | nsaaoscpcX1.a1 | Does not affect quality |
D150701.24 | NSA/CPC/X1 - Reprocess: reprocessing from raw data in preparation for not-yet-released b1 level | nsaaoscpcX1.a1 | Does not affect quality |
D160614.5 | NSA/AOS/AETH/CLAP/CPC/NEPHELOMETER/X1 - Data missing | nsaaoscpcX1.a1 | Missing |
D160803.8 | NSA/AOS/AETH/CLAP/CPC/NEPHELOMETER/X1 - data collection error | nsaaoscpcX1.a1 | Missing |
D160927.3 | NSA/AOS/CLAP/CPC/NEPHELOMETER/X1 - System maintenance | nsaaoscpcX1.a1 | Incorrect |
D160927.4 | NSA/AOS/CLAP/CPC/NEPHELOMETER/X1 - Site power outage | nsaaoscpcX1.a1 | Missing |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/01/2011 | 0100 | 07/06/2012 | 1200 | Does not affect quality |
Subject: | NSA/CPC/X1 - Global metadata error |
DataStreams: | nsaaoscpcX1.a1 |
Description: | The global metadata in the nsaaoscpcX1.a1 file incorrectly specifies the CPC model number as "3372". The correct model number is "3010". This is a metadata error only. The data are not affected. A low priority reprocessing task has been submitted. |
Measurements: | nsaaoscpcX1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/01/2011 | 0000 | 10/01/2015 | 2359 | Does not affect quality |
Subject: | NSA/CPC/X1 - Reprocess: reprocessing from raw data in preparation for not-yet-released b1 |
DataStreams: | nsaaoscpcX1.a1 |
Description: | End to end reprocessing to generate new a1 datastreams is needed so that when the harmonization software is released to production, we will be ready with the a1 datastreams that are input to the subsequent processing software. |
Measurements: | nsaaoscpcX1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/10/2016 | 2007 | 06/13/2016 | 1533 | Missing |
Subject: | NSA/AOS/AETH/CLAP/CPC/NEPHELOMETER/X1 - Data missing |
DataStreams: | nsaaoscpcX1.a1 |
Description: | Communication failure between data acquisition and instruments. |
Measurements: | nsaaoscpcX1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/01/2016 | 2200 | 08/02/2016 | 1650 | Missing |
Subject: | NSA/AOS/AETH/CLAP/CPC/NEPHELOMETER/X1 - data collection error |
DataStreams: | nsaaoscpcX1.a1 |
Description: | Hardware failure of data acquisition laptop. Laptop replaced. |
Measurements: | nsaaoscpcX1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/16/2016 | 1843 | 08/20/2016 | 1847 | Incorrect |
Subject: | NSA/AOS/CLAP/CPC/NEPHELOMETER/X1 - System maintenance |
DataStreams: | nsaaoscpcX1.a1 |
Description: | Data is either missing or instrument was being calibrated |
Measurements: | nsaaoscpcX1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/21/2016 | 2052 | 08/22/2016 | 1340 | Missing |
Subject: | NSA/AOS/CLAP/CPC/NEPHELOMETER/X1 - Site power outage |
DataStreams: | nsaaoscpcX1.a1 |
Description: | Site power outage |
Measurements: | nsaaoscpcX1.a1:
|