Data Quality Reports for Session: 181959 User: vghate Completed: 11/30/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D120414.4SGP/QCRAD/E10 - Tracker failuresgpqcrad1longE10.c2Incorrect
D120509.5SGP/QCRAD/E10 - Noisy upwelling longwavesgpqcrad1longE10.c2Incorrect
D120509.6SGP/QCRAD/E10 - Noisy upwelling shortwave fluxsgpqcrad1longE10.c2Incorrect


DQRID : D120414.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/04/2004180001/26/20051600Incorrect
Subject:
SGP/QCRAD/E10 - Tracker failure
DataStreams:sgpqcrad1longE10.c2
Description:
During the night of 11/05-06 2004 the tracker failed at this location. During CM on 12/01, 
power cycling returned the tracker to service. However, tracker was not properly 
tracking in the AM. Tracker failed again sometime near 01/01/2005.	CM reloaded the tracker 
program and realigned the tracker on 01/26/2005 1600GMT correcting the problem.

Documented in instrument DQR: D041206.1
Measurements:sgpqcrad1longE10.c2:
  • Best Estimate Global Downwelling Shortwave Hemispheric Irradiance(BestEstimate_down_short_hemisp)
  • Irradiance, shortwave, downwelling, diffuse, hemispheric, pyranometer(down_short_diffuse_hemisp)
  • Shortwave Direct Normal Irradiance(short_direct_normal)


Back To Table of Contents

DQRID : D120509.5
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/29/2003150008/06/20030500Incorrect
11/30/2001000011/08/20021900Incorrect
Subject:
SGP/QCRAD/E10 - Noisy upwelling longwave
DataStreams:sgpqcrad1longE10.c2
Description:
Upwelling Infrared irradiance signals noisy resulting from problems with pyrgeometer 
signal cable connections.

Documented in instrument DQRs D030110.37, D030110.36, D031027.1
Measurements:sgpqcrad1longE10.c2:
  • Upwelling longwave hemispheric irradiance, pyrgeometer(up_long_hemisp)


Back To Table of Contents

DQRID : D120509.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/22/2003014607/02/20031400Incorrect
Subject:
SGP/QCRAD/E10 - Noisy upwelling shortwave flux
DataStreams:sgpqcrad1longE10.c2
Description:
Beginning 6/22, upwelling shortwave values frequently dropped well below 0 W/m^2 
(occasionally dropping below -50 W/m^2) during the nighttime hours.  Daytime values were 
excessively high and noisy. Instrument wiring was suspected and was corrected 07/02/2003.

Documented in instrument DQR D030701.1
Measurements:sgpqcrad1longE10.c2:
  • Upwelling shortwave hemispheric irradiance, pyranometer(up_short_hemisp)


Back To Table of Contents



END OF DATA