DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D131018.9 | ENA/MET/C1 - Wind sensor installed at 6 meters. PWD and ORG temporarily mounted to tower. | enametC1.b1 | Does not affect quality |
D131023.2 | ENA/MET/C1 - PWD issues | enametC1.b1 | Incorrect |
D131210.2 | ENA/MET/C1 - Wind sensor data questionable | enametC1.b1 | Suspect |
D150123.1 | ENA/MET/C1 - Moisture inside optical rain gauge | enametC1.b1 | Incorrect |
D150709.1 | ENA/MET/C1 - Optical rain gauge false precipitation | enametC1.b1 | Incorrect |
D150709.2 | ENA/MET/C1 - Present weather detector false 1 minute visibility | enametC1.b1 | Suspect |
D160108.6 | ENA/MET/C1 - Ventilator maintenance | enametC1.b1 | Incorrect |
D160208.1 | ENA/MET/C1 - Reprocessed and Corrected: Wind direction off by 180 degrees | enametC1.b1 | Does not affect quality |
D160324.1 | ENA/MET/C1 - Optical rain gauge precipitation test | enametC1.b1 | Incorrect |
D160325.5 | ENA/MET/C1 - Optical rain gauge error | enametC1.b1 | Incorrect |
D160427.7 | ENA/C1 - Reprocess: Slightly incorrect location fields | enametC1.b1 | Suspect |
D160914.3 | ENA/MET/C1 - Aspirator wire broken | enametC1.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/01/2013 | 0000 | 02/24/2014 | 0840 | Does not affect quality |
Subject: | ENA/MET/C1 - Wind sensor installed at 6 meters. PWD and ORG temporarily mounted to tower. |
DataStreams: | enametC1.b1 |
Description: | The wind sensor was temporarily mounted at 6 meters, not the standard 10 meters, during this time. Also, the PWD and ORG were mounted to the tower during this time. They have now been moved to permanent mounting on separate tripods. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/01/2013 | 0000 | 10/22/2013 | 2027 | Incorrect |
Subject: | ENA/MET/C1 - PWD issues |
DataStreams: | enametC1.b1 |
Description: | A mounting issue with the present weather detector caused low visibility values and incorrect present weather codes. Also, any visibility values over 9999 meters were reported as 0. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/27/2013 | 1700 | 11/18/2013 | 2359 | Suspect |
Subject: | ENA/MET/C1 - Wind sensor data questionable |
DataStreams: | enametC1.b1 |
Description: | The vector wind speed, wind direction, and standard deviation were occasionally 0, when wind direction was between 355 and 360 degrees. Data values of 0 should be disregarded. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/14/2015 | 1308 | 01/14/2015 | 1604 | Incorrect |
Subject: | ENA/MET/C1 - Moisture inside optical rain gauge |
DataStreams: | enametC1.b1 |
Description: | Moisture inside the optical rain gauge sensor caused incorrect data to be recorded. Sensor was replaced. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/11/2015 | 0806 | 06/11/2015 | 0806 | Incorrect |
05/19/2015 | 1004 | 05/19/2015 | 1004 | Incorrect |
06/23/2014 | 1608 | 06/23/2014 | 1609 | Incorrect |
06/22/2014 | 1406 | 06/22/2014 | 1406 | Incorrect |
03/26/2015 | 0944 | 03/26/2015 | 0944 | Incorrect |
12/20/2014 | 1226 | 12/20/2014 | 1226 | Incorrect |
06/16/2014 | 0818 | 06/16/2014 | 0819 | Incorrect |
08/15/2014 | 0840 | 08/15/2014 | 0841 | Incorrect |
03/04/2015 | 1451 | 03/04/2015 | 1452 | Incorrect |
03/01/2015 | 0901 | 03/01/2015 | 0901 | Incorrect |
06/12/2015 | 0826 | 06/12/2015 | 0826 | Incorrect |
06/05/2015 | 0846 | 06/05/2015 | 0846 | Incorrect |
07/02/2014 | 1115 | 07/02/2014 | 1115 | Incorrect |
03/06/2015 | 1036 | 03/06/2015 | 1036 | Incorrect |
03/27/2015 | 1016 | 03/27/2015 | 1016 | Incorrect |
02/22/2015 | 1600 | 02/22/2015 | 1600 | Incorrect |
Subject: | ENA/MET/C1 - Optical rain gauge false precipitation |
DataStreams: | enametC1.b1 |
Description: | Routine cleaning caused incorrect precipitation to be recorded by the optical rain gauge. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/02/2014 | 1522 | 07/02/2014 | 1522 | Suspect |
06/05/2015 | 0843 | 06/05/2015 | 0844 | Suspect |
06/23/2014 | 1331 | 06/23/2014 | 1331 | Suspect |
03/26/2015 | 1032 | 03/26/2015 | 1032 | Suspect |
Subject: | ENA/MET/C1 - Present weather detector false 1 minute visibility |
DataStreams: | enametC1.b1 |
Description: | One minute visibility values are suspected to be false during the indicated times due to routine cleaning. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/23/2015 | 1455 | 12/23/2015 | 1650 | Incorrect |
Subject: | ENA/MET/C1 - Ventilator maintenance |
DataStreams: | enametC1.b1 |
Description: | Data are incorrect during this time due to ventilator maintenance. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/05/2016 | 1749 | 02/07/2016 | 1137 | Does not affect quality |
Subject: | ENA/MET/C1 - Reprocessed and Corrected: Wind direction off by 180 degrees |
DataStreams: | enametC1.b1 |
Description: | DATA REPROCESSED and CORRECTED: The wind sensor was not aligned correctly. Wind directions during this time are off by 180 degrees. The raw data were modified and the data were run through the ingest to address the issue. The data were Archived in July 2016. Please retrieve the reprocessed data for use in your analysis. You may find these data using the ARM Discovery tool at the following link: http://www.archive.arm.gov/discovery/#v/results/s/finst::met/fsite::ena/ffac::ena.C1 ORIGINAL DQR CATEGORY: Red( Incorrect) REPROCESSED and CORRECTED DATA ARCHIVED:2016-07 REPROCESS IDENTIFICATION NUMBER: RID 1424 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- The wind sensor was not aligned correctly. Wind directions during this time are off by 180 degrees. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/23/2016 | 1651 | 03/23/2016 | 1652 | Incorrect |
Subject: | ENA/MET/C1 - Optical rain gauge precipitation test |
DataStreams: | enametC1.b1 |
Description: | Precipitation recorded by the optical rain gauge during this time is incorrect. Response to precipitation was being tested. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/12/2016 | 1710 | 03/12/2016 | 1711 | Incorrect |
03/12/2016 | 1752 | 03/12/2016 | 1752 | Incorrect |
03/12/2016 | 1749 | 03/12/2016 | 1750 | Incorrect |
03/12/2016 | 1822 | 03/12/2016 | 1822 | Incorrect |
03/12/2016 | 1747 | 03/12/2016 | 1747 | Incorrect |
03/12/2016 | 1825 | 03/12/2016 | 1825 | Incorrect |
03/12/2016 | 1801 | 03/12/2016 | 1802 | Incorrect |
03/12/2016 | 1804 | 03/12/2016 | 1805 | Incorrect |
03/12/2016 | 1812 | 03/12/2016 | 1812 | Incorrect |
03/12/2016 | 1817 | 03/12/2016 | 1817 | Incorrect |
03/12/2016 | 1759 | 03/12/2016 | 1759 | Incorrect |
Subject: | ENA/MET/C1 - Optical rain gauge error |
DataStreams: | enametC1.b1 |
Description: | During these times the optical rain gauge malfunctioned and recorded invalid precipitation. Sensor was replaced. |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/29/2013 | 0941 | 04/30/2016 | 2359 | Suspect |
Subject: | ENA/C1 - Reprocess: Slightly incorrect location fields |
DataStreams: | enametC1.b1 |
Description: | Some of the instruments are being processed with the previous "GRW-Azores" lat/lon/alt instead of the new "ENA-Azores" lat/lon/alt. The differences are minor, but will be corrected. The respective GRW and ENA lat, lon, and alt values are as follows: GRW lat = 39.0911 ; ENA lat = 39.0916 ; GRW lon = -28.0297 ; ENA lon = -28.0257 ; GRW alt = 26 ; ENA alt = 30.48 ; |
Measurements: | enametC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/06/2016 | 0800 | 09/07/2016 | 0845 | Does not affect quality |
Subject: | ENA/MET/C1 - Aspirator wire broken |
DataStreams: | enametC1.b1 |
Description: | A broken wire on the temperature/relative humidity aspirator caused the fan to stop working. Measurements do not appear to be affected. |
Measurements: | enametC1.b1:
|