DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D081007.2 | HFE/ECOR/M1 - Sonic failure | hfe30ecorM1.b1 | Incorrect |
D091007.1 | HFE/ECOR/M1 - Flux Data Incorrect For Some Wind Directions | hfe30ecorM1.b1 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/05/2008 | 0400 | 10/12/2008 | 0230 | Incorrect |
Subject: | HFE/ECOR/M1 - Sonic failure |
DataStreams: | hfe30ecorM1.b1 |
Description: | The sonic datastream were "garbled", possibly associated with a serial line damage to the LI-7500 serial port or the Versalogic SBC serial port. Garbled data condition existed through 10/09/08 0030 GMT followed by missing data through 10/12/08 0230 GMT. |
Measurements: | hfe30ecorM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/08/2008 | 0000 | 12/28/2008 | 2359 | Incorrect |
Subject: | HFE/ECOR/M1 - Flux Data Incorrect For Some Wind Directions |
DataStreams: | hfe30ecorM1.b1 |
Description: | For some wind directions the horizontal fetch was not representative of the fields surrounding the AMF. Therefore, for the wind direction range 191-349 degrees, the fluxes are affected by insufficient fetch, and surfaces, buildings, and vegetation that are not similar to the local field conditions. |
Measurements: | hfe30ecorM1.b1:
|