DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D110415.2 | SGP/MET/E13 - PWD data incorrect/missing | sgpmetE13.b1 | Incorrect |
D110419.1 | SGP/MET/E13 - Missing PWD data | sgpmetE13.b1 | Missing |
D120928.1 | SGP/MET/E13 - Low logger voltage | sgpmetE13.b1 | Suspect |
D140103.2 | SGP/MET/E13 - Ice on wind sensor | sgpmetE13.b1 | Incorrect |
D151201.2 | SGP ALL INSTRUMENTS - Icing Event | sgpmetE13.b1 | Does not affect quality |
D151218.8 | SGP/MET/E13 - Data suspect due to system power issues | sgpmetE13.b1 | Suspect |
D160104.7 | SGP Site Power Outage Due to Winter Storm | sgpmetE13.b1 | Does not affect quality |
D160203.4 | SGP/MET/E13 - False tips in high winds | sgpmetE13.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/15/2011 | 1300 | 02/18/2011 | 2200 | Incorrect |
Subject: | SGP/MET/E13 - PWD data incorrect/missing |
DataStreams: | sgpmetE13.b1 |
Description: | Data collection problems during the time period specified resulted in incorrect or missing PWD data. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/09/2010 | 0000 | 01/10/2011 | 2000 | Missing |
Subject: | SGP/MET/E13 - Missing PWD data |
DataStreams: | sgpmetE13.b1 |
Description: | PWD data were missing due to an accidental reset on the instrument. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/08/2012 | 2052 | 09/16/2012 | 1439 | Suspect |
Subject: | SGP/MET/E13 - Low logger voltage |
DataStreams: | sgpmetE13.b1 |
Description: | Low logger voltage was reported. Low voltage may result in data spikes or dropouts. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/21/2013 | 1842 | 12/23/2013 | 1940 | Incorrect |
Subject: | SGP/MET/E13 - Ice on wind sensor |
DataStreams: | sgpmetE13.b1 |
Description: | Wind speed and direction are flat-lined due to ice accumulation on the sensor. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/27/2015 | 0000 | 11/30/2015 | 2359 | Does not affect quality |
Subject: | SGP ALL INSTRUMENTS - Icing Event |
DataStreams: | sgpmetE13.b1 |
Description: | An icing event (winter storm Cara) passed slowly through the area during this time frame. Instruments at the SGP may have been affected by ice accumulation. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/30/2015 | 1654 | 12/04/2015 | 1516 | Suspect |
Subject: | SGP/MET/E13 - Data suspect due to system power issues |
DataStreams: | sgpmetE13.b1 |
Description: | Issues with power supply to the system caused outages and suspect data during this time. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/26/2015 | 0000 | 01/01/2016 | 2359 | Does not affect quality |
Subject: | SGP Site Power Outage Due to Winter Storm |
DataStreams: | sgpmetE13.b1 |
Description: | On Saturday and Sunday, December 26 and 27th a powerful winter storm (Goliath) brought sleet and freezing rain to much of Oklahoma with wind gusts of 45 MPH at times. The result was very very slick roads and mass power outages. The SGP central facility lost power at 8:55 PM CDT on Sunday, December 27th. The power was restored on 7:56 PM CDT on Wednesday, December 30th Site Emergency procedures were activated and Technicians drained water out of instrument reservoirs and other measures as needed, early Monday morning. On Wednesdays as roads and power started was restored to much of the areas east of I-35 , Site Technicians performed maintenance on several Extended Facilities. During this period, data are potentially missing, incorrect, or suspect. Carefully inspect the data before use. |
Measurements: | sgpmetE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/21/1993 | 0000 | 01/12/2016 | 1958 | Does not affect quality |
Subject: | SGP/MET/E13 - False tips in high winds |
DataStreams: | sgpmetE13.b1 |
Description: | The TBRG's were mounted at a height that made them prone to vibrations caused by high winds which may have caused false tips. The end date of this DQR indicates when the rain gauge was lowered to mitigate these effects. Effects on the total precipitation amounts are assumed to be negligible. |
Measurements: | sgpmetE13.b1:
|