DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D161121.9 | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE11.b1 | Incorrect |
D170403.6 | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE11.b1 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/11/2016 | 0230 | 11/14/2016 | 1730 | Incorrect |
Subject: | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE11.b1 |
Description: | Sensible and latent heat fluxes were incorrect when the Automatic Exchange Mechanism was not working. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/15/2016 | 0000 | 03/22/2017 | 1630 | Incorrect |
Subject: | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE11.b1 |
Description: | A wiring mistake caused the top and bottom temperature measurements to be incorrect (top and bottom relative humidity probe temperatures used to determine vapor pressure were correct). Thus the sensible and latent heat fluxes were not correctly calculated. |
Measurements: | sgp30ebbrE11.b1:
|