DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D160512.2 | SGP/EBBR/E13 - Sensible and Latent Heat Flux Incorrect | sgp30ebbrE13.b1 | Suspect |
D160603.2 | SGP/EBBR/E9 - Data Missing or Incorrect | sgp30ebbrE9.b1 | Incorrect |
D160614.12 | SGP/EBBR/E34 - Missing Data | sgp30ebbrE34.b1 | Missing |
D160715.8 | SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE13.b1 | Incorrect |
D160802.7 | SGP/EBBR/E35 - Spikes with Sensible and Latent Heat Fluxes | sgp30ebbrE35.b1 | Suspect |
D160803.16 | SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect | sgp30ebbrE12.b1 | Incorrect |
D160804.1 | SGP/EBBR/E39 - Barometric Pressure Incorrect | sgp30ebbrE39.b1 | Incorrect |
D160809.1 | SGP/EBBR/E9 - Data Missing | sgp30ebbrE9.b1 | Missing |
D160810.3 | SGP/EBBR/E39 - EBBR Flux Measurements Sometimes Incorrect for Southerly Winds | sgp30ebbrE39.b1 | Suspect |
D160811.1 | SGP/EBBR/E11 - Soil Temperature 1 Spiking | sgp30ebbrE11.b1 | Suspect |
D160826.3 | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE11.b1 | Incorrect |
D160826.5 | SGP/EBBR/E11 - Soil temperature 2 Spiking | sgp30ebbrE11.b1 | Suspect |
D160930.4 | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE11.b1 | Incorrect |
D161007.2 | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE11.b1 | Suspect |
D161121.9 | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE11.b1 | Incorrect |
D161215.1 | SGP/EBBR/E9 - Some Measurements Incorrect | sgp30ebbrE9.b1 | Suspect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/08/2016 | 1030 | 05/05/2016 | 2000 | Suspect |
Subject: | SGP/EBBR/E13 - Sensible and Latent Heat Flux Incorrect |
DataStreams: | sgp30ebbrE13.b1 |
Description: | Sensible and Latent Heat Flux were sometimes incorrect when Soil Heat Flow 5 was incorrect. The EBBR unit was replaced not only to resolve problems with the unit, but to provide a newly calibrated unit for an IOP. |
Measurements: | sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/25/2016 | 0200 | 06/01/2016 | 1800 | Incorrect |
Subject: | SGP/EBBR/E9 - Data Missing or Incorrect |
DataStreams: | sgp30ebbrE9.b1 |
Description: | All data were incorrect or missing because the power supply failed. |
Measurements: | sgp30ebbrE9.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/25/2016 | 1100 | 05/31/2016 | 1734 | Missing |
Subject: | SGP/EBBR/E34 - Missing Data |
DataStreams: | sgp30ebbrE34.b1 |
Description: | All data missing. |
Measurements: | sgp30ebbrE34.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/02/2016 | 1030 | 07/12/2016 | 1430 | Incorrect |
Subject: | SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE13.b1 |
Description: | Sensible and latent fluxes were incorrect when soil heat flow 3 was incorrect. Soil heat flow probe 3 was damaged, apparently by rodents. |
Measurements: | sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/20/2016 | 0400 | 07/23/2016 | 0200 | Suspect |
Subject: | SGP/EBBR/E35 - Spikes with Sensible and Latent Heat Fluxes |
DataStreams: | sgp30ebbrE35.b1 |
Description: | Spikes in Soil Heat Flow 3 sometimes made Sensible and Latent Heat Fluxes incorrect. |
Measurements: | sgp30ebbrE35.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/14/2016 | 1430 | 07/26/2016 | 1800 | Incorrect |
Subject: | SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect |
DataStreams: | sgp30ebbrE12.b1 |
Description: | Sensible and latent heat fluxes were incorrect because the measured net radiation was too small. |
Measurements: | sgp30ebbrE12.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/23/2016 | 0000 | 08/02/2016 | 1700 | Incorrect |
Subject: | SGP/EBBR/E39 - Barometric Pressure Incorrect |
DataStreams: | sgp30ebbrE39.b1 |
Description: | The barometric pressure did not trend well with the MET system barometric pressure. However, the sensible and latent heat fluxes were not deleteriously affected by the small differences of the EBBR barometric pressure from the MET barometric pressure. |
Measurements: | sgp30ebbrE39.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/01/2016 | 2030 | 08/05/2016 | 1830 | Missing |
Subject: | SGP/EBBR/E9 - Data Missing |
DataStreams: | sgp30ebbrE9.b1 |
Description: | All data missing. |
Measurements: | sgp30ebbrE9.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/30/2015 | 2100 | 08/02/2016 | 1730 | Suspect |
Subject: | SGP/EBBR/E39 - EBBR Flux Measurements Sometimes Incorrect for Southerly Winds |
DataStreams: | sgp30ebbrE39.b1 |
Description: | When the wheat was at it's peak and for southerly winds, the EBBR flux measurements reflected combined fluxes from both the grass between the EBBR and the wheat and the wheat itself. The EBBR AEM height was not high enough to capture fluxes from just the wheat for southerly wind directions. EBBR fluxes for northerly directions (from grass) were consistent with the ECOR measured fluxes. The EBBR AEM was raised on 2 Aug 2016 and fluxes from southerly directions have been similar to those from the ECOR since then. |
Measurements: | sgp30ebbrE39.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/05/2016 | 1000 | 08/08/2016 | 1600 | Suspect |
Subject: | SGP/EBBR/E11 - Soil Temperature 1 Spiking |
DataStreams: | sgp30ebbrE11.b1 |
Description: | Soil temperature 1 spiked at times, the result of loose lead connections. This did not have a significant effect on the calculation of sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/19/2016 | 1030 | 08/22/2016 | 1700 | Incorrect |
Subject: | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE11.b1 |
Description: | Soil temperature 1 and soil moisture 1 were incorrect, resulting in the sensible and latent heat fluxes being incorrect. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/15/2016 | 0700 | 08/22/2016 | 1200 | Suspect |
Subject: | SGP/EBBR/E11 - Soil temperature 2 Spiking |
DataStreams: | sgp30ebbrE11.b1 |
Description: | Sensible and latent heat flux was not deleteriously affected when small spikes occurred in soil temperature 2. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/30/2016 | 1930 | 09/19/2016 | 1600 | Incorrect |
Subject: | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE11.b1 |
Description: | Sensible and latent heat fluxes were incorrect when the soil moisture 1 and/or soil temperature 1 measurements went offscale. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/11/2016 | 0800 | 10/05/2016 | 1800 | Suspect |
Subject: | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE11.b1 |
Description: | The sensible and latent heat fluxes were incorrect when the soil temperatures spiked, the result of a failing multiplexer. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/11/2016 | 0230 | 11/14/2016 | 1730 | Incorrect |
Subject: | SGP/EBBR/E11 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE11.b1 |
Description: | Sensible and latent heat fluxes were incorrect when the Automatic Exchange Mechanism was not working. |
Measurements: | sgp30ebbrE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/01/2016 | 1830 | 12/14/2016 | 1616 | Suspect |
11/19/2015 | 1730 | 12/28/2015 | 0600 | Suspect |
Subject: | SGP/EBBR/E9 - Some Measurements Incorrect |
DataStreams: | sgp30ebbrE9.b1 |
Description: | The wrong data logger program (for unit 6) was loaded into the E9 EBBR, instead of the correct program (for unit 15). This happened for two periods: 11/19/2015 1730 - 12/28/2015 0600 and 06/01/2016 1830 - 12/14/2016 1630. This affects a number of measurements, but the effect on the primary variables sensible and latent heat fluxes was within the measurement uncertainty. Reprocessing of the measurements would be very complicated, as we would have to back out through polynomials, etc. Since the effect on the sensible and latent heat fluxes is within the measurement uncertainty, the effort required for re-processing doesn't justify the time and expense of doing it. |
Measurements: | sgp30ebbrE9.b1:
|