Measurements |
- CCN_Q_sample_2 (AOS CCN volumetric flow rate of sample air, second column)
- CCN_overflow_1 (Number of particles that are larger than 10um, first column)
- CCN_temp_unstable_1 (AOS CCN logical value, indicating whether the instrument has reached thermal gradient stabilization and is within 0.4 degrees C of the set point, first column)
- CCN_alarm_code_1 (CCN alarm code expressed as a summation of powers of 2. 0 indicates no detected problem, first column)
- CCN_proportional_valve_voltage_1 (CCN Proportional valve voltage, first column)
- N_CCN_dN_1 (AOS CCN droplet count by bin size, first column)
- CCN_first_stage_monitor_voltage_2 (First stage monitor voltage, second column)
- CCN_laser_current_1 (AOS CCN OPC laser current, first column)
- CCN_baseline_monitor_1 (AOS CCN voltage used by DMT for OPC diagnostic purposes, first column)
- CCN_supersaturation_set_point_2 (AOS CCN sample supersaturation set point value reported by instrument, second column)
- CCN_T_read_TEC3_2 (AOS CCN (read) temperature at bottom of column, second column)
- CCN_OPC_set_2 (AOS CCN set point temperature for the optical particle counter (OPC), second column)
- CCN_T_inlet_1 (AOS CCN temperature of sample air at entrance to instrument, first_column)
- size_bin_bounds (Droplet bin bounds)
- CCN_baseline_monitor_2 (AOS CCN voltage used by DMT for OPC diagnostic purposes, second column)
- CCN_T_OPC_1 (AOS CCN temperature of the optical particle counter, first column)
- CCN_first_stage_monitor_voltage_1 (First stage monitor voltage, first column)
- CCN_T_read_TEC3_1 (AOS CCN (read) temperature at bottom of column, first column)
- CCN_T_read_TEC2_1 (AOS CCN observed temperature at middle of column, first column)
- CCN_T_read_TEC1_1 (AOS CCN observed temperature at top of column, first column)
- CCN_laser_current_2 (AOS CCN OPC laser current, second column)
- CCN_T_read_TEC2_2 (AOS CCN observed temperature at middle of column, second column)
- CCN_Q_sheath_1 (AOS CCN volumetric flow rate of sheath air, first column)
- CCN_T_set_TEC2_1 (AOS CCN set point for temperature at middle of column, first column)
- CCN_T_nafion_1 (AOS CCN Nafion temperature, first column)
- CCN_T_nafion_set_2 (AOS CCN set temperature for the Nafion humidifier, second column)
- CCN_temperature_gradient_1 (Temperature difference between CCN_T_set_TEC3_1 and CCN_T_set_TEC1_1, first column)
- CCN_T_inlet_set_1 (AOS CCN set point temperature for the inlet manifold, first column)
- N_CCN_1 (AOS number concentration of CCN, first column)
- N_CCN_bin_number_2 (AOS bin number of lowest channel of OPC include in summation of N_CCN, second column)
- CCN_T_set_TEC1_1 (AOS CCN set point for temperature at top of column, first column)
- CCN_T_inlet_2 (AOS CCN set point temperature for the inlet manifold, second column)
- size_bin (Size bins for CCN droplet count)
- CCN_T_set_TEC3_1 (AOS CCN set point for temperature at bottom of column, first column)
- CCN_P_sample_1 (AOS CCN sample pressure, first column)
- CCN_temp_unstable_2 (AOS CCN logical value, indicating whether the instrument has reached thermal gradient stabilization and is within 0.4 degrees C of the set point, second column)
- CCN_T_set_TEC2_2 (AOS CCN set point for temperature at middle of column, second column)
- CCN_T_read_TEC1_2 (AOS CCN observed temperature at top of column, second column)
- CCN_temperature_gradient_2 (Temperature difference between CCN_T_set_TEC3_2 and CCN_T_set_TEC1_2, second column)
- CCN_T_sample_2 (AOS CCN temperature of sample air entering the column, second column)
- CCN_T_sample_1 (AOS CCN temperature of sample air entering the column, first column)
- N_CCN_dN_2 (AOS CCN droplet count by bin size, second column)
- CCN_proportional_valve_voltage_2 (CCN Proportional valve voltage, second column)
- CCN_T_set_TEC3_2 (AOS CCN set point for temperature at bottom of column, second column)
- CCN_P_sample_2 (AOS CCN sample pressure, second column)
- CCN_T_nafion_2 (AOS CCN Nafion temperature, second column)
- CCN_Q_sample_1 (AOS CCN volumetric flow rate of sample air, first column)
- CCN_T_nafion_set_1 (AOS CCN set temperature for the Nafion humidifier, first column)
- CCN_Q_sheath_2 (AOS CCN volumetric flow rate of sheath air, second column)
- N_CCN_2 (AOS number concentration of CCN, second column)
- CCN_alarm_code_2 (CCN alarm code expressed as a summation of powers of 2. 0 indicates no detected problem, second column)
- CCN_T_OPC_2 (AOS CCN temperature of the optical particle counter, second column)
- CCN_OPC_set_1 (AOS CCN set point temperature for the optical particle counter (OPC), first column)
- CCN_T_set_TEC1_2 (AOS CCN set point for temperature at top of column, second column)
- N_CCN_bin_number_1 (AOS bin number of lowest channel of OPC include in summation of N_CCN, first column)
- CCN_T_inlet_set_2 (AOS CCN temperature of sample air at entrance to instrument, second column)
- CCN_supersaturation_set_point_1 (AOS CCN sample supersaturation set point value reported by instrument, first column)
- CCN_overflow_2 (Number of particles that are larger than 10um, second column)
|