DQRID : D950626.10
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/12/1995131504/12/19951400Incorrect
04/11/1995123004/12/19950615Incorrect
more
Subject:
SGP/EBBR/E26 - Stopped Ventilation Fan
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
On April 11, 1995, a site operator discovered the right aspirator ventilation
fan of the EBBR to be stopped.  Inspection of the data indicates that this
condition occurred during the two periods shown above; the fan apparently
worked briefly inbetween the periods.  Lack of ventilation of
the temperature and relative humidity sensors attached to the AEM results
in incorrect measurements of air temperature and relative humidity by the
right aspirator probes, and therefore all quantities calculated from them,
including sensible and latent heat fluxes, are incorrect as well.
The quantities that are incorrect for the periods indicated are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, mv_hum_r, tair_r

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h
Suggestions: 
Measurements:sgp5ebbrE26.b1:
  • vapor_pressure_bottom
  • rh_top_fraction
  • temp_trh_top
  • temp_air_bottom
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
more
sgp15ebbrE26.b1:
  • temp_trh_right_rr
  • temp_air_right
  • rh_right_mv
more
sgp30ebbrE26.b1:
  • bowen_ratio
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_top
  • latent_heat_flux
  • temp_air_bottom
  • vapor_pressure_top
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_bottom
  • temp_trh_bottom
more

Close this window