DQRID : D001005.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
08/01/2000000008/31/20002359Does not affect quality
more
Subject:
SGP/OKM - Overview of Automated Data Quality - August 2000
DataStreams:sgp05okmX1.b1, sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.a1
Description:
Below is an overview from Chris Fiebrich, the Mesonet QA manager
of the automated quality assurance results for the August 2000
Oklahoma Mesonet data.


TAIR    Current:        None 
        Added:          None
        Resolved:       None 

RELH    Current:        #5084 WAUR Sensor found to be 7% high 
                              during Spring Pass 2000 comparison
        Added:          None
        Resolved:       #5140 MAYR Replaced sensor exceeding
                              103%
 
WDIR    Current:        None 
        Added:          None
        Resolved:       None

WSPD    Current:        None 
        Added:          None
        Resolved:       #5158 MADI Replaced sensor due to noisy
                              bearings
                        #5195 SALL Replaced sensor due to noisy
                              bearings 

PRES    Current:        None
        Added:          None
        Resolved:       #5086 RETR Replaced sensor with high bias 
                        
SRAD    Current:        #5070 HOOK Sensor found to be 6.5% high
                              during Spring Pass 2000 comparison
                        #5072 KETC Monthly QA indicates 5-10%
                              high bias
                        #5091 WIST Sensor found to be 5.5% low
                              during Spring Pass 2000 comparison
                        #5097 BESS Sensor found to be 10% high
                              during Spring Pass 2000 comparison
                        #5099 MEDF Sensor found to be 8% low
                              during Spring Pass 2000 comparison
                        #5101 WALT Sensor found to be 10% low
                              during Spring Pass 2000 comparison
                        #5111 GOOD Sensor found to be 6.7% high
                              during Spring Pass 2000 comparison
                        #5115 FREE Sensor found to be 6% high
                              during Spring Pass 2000 comparison
                        #5159 FAIR Sensor stuck at 0
        Added:          None
        Resolved:       #5079 WASH Replaced sensor with high bias

RAIN    Current:        #5208 MTHE Gauge double-tipping on one 
                              side
        Added:          None 
        Resolved:       #5078 BURN Removed spider web that was
                              clogging gauge              
                        #5098 BESS Replaced gauge that was found
                              to be double-tipping on one side of
                              bucket during Spring Pass 2000 test
                        #5162 TAHL Replaced gauge that was found
                              to be double-tipping
                        #5183 CHAN Replaced suspect switch  
                        #5184 BOWL Replaced switch found to be
                              double-tipping
                        #5185 TIPT Replaced gauge despite 4 success-
                              ful drip tests because site has had
                              longest dry period
                        #5188 VINI Replaced gauge found to be
                              double-tipping on one side
                        #5202 SKIA Replaced gauge found to double-  
                              tip occasionally

TA9M    Current:        None
        Added:          None
        Resolved:       None

WS2M    Current:        None
        Added:          None 
        Resolved:       #5141 DURA Replaced sensor reporting constant
                              0 m/s 

TS10    Current:        #5178 MADI Sensor sporadically reports +5 C
                              offset
                        #5199 DURA Sensor reporting sporadically and
                              8 C warm
        Added:          None
        Resolved:       None

TB10    Current:        None
        Added:          None
        Resolved:       #5179 SALL Replaced bad sensor
                        #5200 GRA2 Repaired cracked ground over bare
                              plot

TS05    Current:        #5194 FAIR Sensor has 5 C cool bias since
                              lightning strike
        Added:          None
        Resolved:       None

TB05    Current:        #5187 DURA Sensor stuck at -273.1 C 
        Added:          None
        Resolved:       #5201 GRA2 Repaired cracked ground over bare
                              plot

TS30    Current:        None  
        Added:          None
        Resolved:       None

----------------------------------------------------------------
                                ARS QA REPORT
----------------------------------------------------------------

TAIR    Current:        #5180 A182 Sensor found to be 2.5 C
                              warm during ARS pass
        Added:          None
        Resolved:       None

RELH    Current:        None 
        Added:          None
        Resolved:       None

SRAD    Current:        None
        Added:          None
        Resolved:       None

RAIN    Current:        None
        Added:          None
        Resolved:       None
                        
TS05    Current:        #5181 A132 Monthly QA indicates 4 C
                              warm bias during all times of day
                        #5203 A167 Sensor reporting erratically 
                              and has 10 C warm bias
        Added:          None
        Resolved:       None

TS10    Current:        #5182 A167 Monthly QA indicates 4 C
                              warm bias during all times of day
        Added:          None
        Resolved:       None 

TS15    Current:        None 
        Added:          None
        Resolved:       None                                

TS30    Current:        #5157 A165 Reporting erratic observations
        Added:          None
        Resolved:       None                                

========================================================================

LEGEND
TAIR    Air Temperature measured at 1.5 meters
RELH    Relative Humidity measured at 1.5 meters
WDIR    Wind Direction measured at 10 meters
WSPD    Wind Speed measured at 10 meters
PRES    Pressure
SRAD    Incident Solar Radiation
RAIN    Rainfall
TA9M    Air Temperature measured at 9 meters
WS2M    Wind Speed measured at 2 meters
TS10    Soil Temperature measured at 10 cm under native sod
TB10    Soil Temperature measured at 10 cm under bare soil
TS05    Soil Temperature measured at 5 cm under native sod
TB05    Soil Temperature measured at 5 cm under bare soil
TS15    Soil Temperature measured at 15 cm under native sod
TS30    Soil Temperature measured at 30 cm under native sod

=======================================================================
Suggestions: 
Measurements:sgp05okmX1.b1:
  • srad
  • wspd_2m
  • wspd_sigma
  • rh
  • wvec_10m
  • tdry_1_5m
  • prec_amt
  • wdir_sigma
  • wdir_10m
  • wspd_10m
  • tdry_9m
  • wspd_max
  • pres
more
sgp05okmX1.a1:
  • prec_amt
  • wvec_10m
  • pres
  • wspd_sigma
  • wdir_10m
  • tdry_1_5m
  • wspd_max
  • wspd_2m
  • rh
  • tdry_9m
  • srad
  • wdir_sigma
more
sgp15okmX1.b1:
  • tbare10
  • tsoil30
  • tsoil10
  • tbare5
  • tsoil5
more
sgp15okmX1.a1:
  • tsoil5
  • tsoil10
  • tbare10
  • tbare30
more

Close this window