DQRID : D010906.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/01/2001000007/31/20012359Does not affect quality
more
Subject:
SGP/OKM - Overview of Automated Data Quality - July 2001
DataStreams:sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1
Description:
Below is an overview from Chris Fiebrich, the Mesonet QA manager
of the automated quality assurance results for the July 2001
Oklahoma Mesonet data.
Notes:

Northwest and southwest Oklahoma were the hot spots of the
state during July.  Average 1800 UTC temperatures in those
areas were over 36 C (97 F).  The 1800 UTC pressure data
revealed corresponding localized areas of low pressure
(heat lows) in those same areas.

===============================================================

TAIR    Current:        None
        Added:          None
        Resolved:       None

RELH    Current:        None
        Added:          None
        Resolved:       #5772 STIL Replaced bad sensor
                        #5950 BRIS Replaced bad sensor
 
WDIR    Current:        None
        Added:          None
        Resolved:       None

WSPD    Current:        None 
        Added:          None
        Resolved:       None

PRES    Current:        None
        Added:          None
        Resolved:       #5898 VANO Initial install of barometer
                        
SRAD    Current:        None
        Added:          None
        Resolved:       #5927 MARS Replaced sensor with high bias
                        #6002 BUTL Replaced sensor with low bias 

RAIN    Current:        #6006 GOOD Soil moisture detected
                              rainfall, but gauge did not
        Added:          None 
        Resolved:       #5778 STIL Fixed double-counting gauge

TA9M    Current:        None
        Added:          None
        Resolved:       #5658 MIAM Tightened wires to sensor

WS2M    Current:        None
        Added:          None 
        Resolved:       #5870 WEBB Replaced sensor with noisy bearings
                        #5877 NEWK Replaced sensor with high
                              starting threshold  
                        #5857 MADI Replaced dead sensor

TS10    Current:        None
        Added:          None
        Resolved:       None         

TB10    Current:        None
        Added:          None
        Resolved:       #5885 DURA Tightened wire to correct erratic data
                        
                  
TS05    Current:        #5756 SLAP Sod is consistently warmer than
                              bare plot
        Added:          None
        Resolved:       #5858 HOLL Corrected erosion problem

TB05    Current:        #5859 ARDM Data suggests sensor is sticking
                              out of ground
        Added:          None
        Resolved:       #5859 ARDM Replaced sensor with high bias

TS30    Current:        None
        Added:          None
        Resolved:       None


----------------------------------------------------------------
                                ARS QA REPORT
----------------------------------------------------------------

TAIR    Current:        None 
        Added:          None
        Resolved:       None

RELH    Current:        None 
        Added:          None 
        Resolved:       None

SRAD    Current:        None
        Added:          None
        Resolved:       #5983 A133 Replaced sensor with high bias

RAIN    Current:        None 
        Added:          None
        Resolved:       None
                        
TS05    Current:        None
        Added:          None
        Resolved:       #5909 A166 Replaced defective sensor
                        #5966 A130 Replaced sensor with 6 C warm bias

TS10    Current:        #6000 A148 Sensor spiking to 50 C
                        #6001 A125 Sensor spiking to 70 C
        Added:          None
        Resolved:       #5926 A159 Replaced gopher-damaged sensor
                        #5910 A125 Replaced defective sensor

TS15    Current:        None
        Added:          None
        Resolved:       #5956 A159 Replaced gopher-damaged sensor
                        #5963 A125 Replaced defective sensor
                        #5965 A155 Replaced defective sensor

TS30    Current:        #5998 A130 Sensor dipping below 0 C
                        #5999 A154 Sensor has a 10 C cool bias
                        #6004 A122 Sensor reporting erratically and
                              out of range
        Added:          None
        Resolved:       #5726 A135 Replaced defective sensor
                        #5717 A134 Replaced defective sensor

========================================================================

LEGEND
TAIR    Air Temperature measured at 1.5 meters
RELH    Relative Humidity measured at 1.5 meters
WDIR    Wind Direction measured at 10 meters
WSPD    Wind Speed measured at 10 meters
PRES    Pressure
SRAD    Incident Solar Radiation
RAIN    Rainfall
TA9M    Air Temperature measured at 9 meters
WS2M    Wind Speed measured at 2 meters
TS10    Soil Temperature measured at 10 cm under native sod
TB10    Soil Temperature measured at 10 cm under bare soil
TS05    Soil Temperature measured at 5 cm under native sod
TB05    Soil Temperature measured at 5 cm under bare soil
TS15    Soil Temperature measured at 15 cm under native sod
TS30    Soil Temperature measured at 30 cm under native sod

=======================================================================
Suggestions: 
Measurements:sgp05okmX1.b1:
  • srad
  • wspd_2m
  • wspd_sigma
  • rh
  • wvec_10m
  • tdry_1_5m
  • prec_amt
  • wdir_sigma
  • wdir_10m
  • wspd_10m
  • tdry_9m
  • wspd_max
  • pres
more
sgp05okmX1.a1:
  • prec_amt
  • wvec_10m
  • pres
  • wspd_sigma
  • wdir_10m
  • tdry_1_5m
  • wspd_10m
  • wspd_max
  • wspd_2m
  • rh
  • tdry_9m
  • srad
  • wdir_sigma
more
sgp15okmX1.b1:
  • tbare10
  • tsoil30
  • tsoil10
  • tbare5
  • tsoil5
more
sgp15okmX1.a1:
  • tsoil5
  • tsoil30
  • tsoil10
  • tbare5
  • tbare10
more

Close this window