DQRID : D011221.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/23/2001054502/25/20011201Incorrect
02/22/2001203102/22/20012301Incorrect
01/01/2001000001/03/20011901Incorrect
01/20/2001091502/09/20010001Incorrect
03/20/2001014503/29/20011601Incorrect
02/28/2001201503/11/20010831Incorrect
02/09/2001061502/11/20011701Incorrect
more
Subject:
SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrect
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
A worn AEM belt caused the AEM to hang frequently.
Gradient measurements, sensible heat flux, latent heat flux,
and Bowen ratio are incorrect during the indicated periods.

The AEM hung on 2/9/01 because of icing from an ice storm.
Suggestions: 