Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/01/2001 | 0000 | 06/20/2002 | 1231 | Incorrect |
Subject: | SGP/EBBR/E12 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE12.b1 |
Description: | Soil Temperature #3 was flaky primarily during nighttime hours and sometimes during early daylight hours. Average soil heat flow, sensible heat flux, and latent heat flux are also affected; these can be recalculated using the remaining good sets of soil sensors as follows: The heat fluxes can be recalculated by using soil sets 1, 2, 4, and 5 as follows: ave_shf = (g1 + g2 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Suggestions: | |
Measurements: | sgp30ebbrE12.b1: more
|