Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/07/2002 | 2029 | 11/07/2002 | 2239 | Incorrect |
11/07/2002 | 1429 | 11/07/2002 | 1629 | Incorrect |
11/07/2002 | 1730 | 11/07/2002 | 1930 | Incorrect |
11/07/2002 | 2331 | 11/08/2002 | 0131 | Incorrect |
11/07/2002 | 1130 | 11/07/2002 | 1316 | Incorrect |
Subject: | SGP/SONDE/B4 - Soundings contaminated by interference |
DataStreams: | sgpqmemwrcolB4.c1, sgpsondewnpnB4.b1, sgplssondeB4.c1, sgpsondewnpnB4.a1 |
Description: | These five soundings, done in succession on 11/07/2002 as part of the SCM/IOP are contaminated by interference. I can't tell whether the problem has to do with improper tuning of the radiosondes, inadequate frequency separation among radiosondes launched from different locations, or some other operator problem. I suspect that there is an operator component to the difficulty because the surface pressure is given as an unreasonably low 896.6 hPa on the 1730 sounding and 886.1 hPa on the 2331 sounding. This may indicate that the ground station was locked another station's radiosonde rather than on the B4 radiosonde. |
Suggestions: | |
Measurements: | sgpsondewnpnB4.b1: more
sgplssondeB4.c1: more sgpqmemwrcolB4.c1: more sgpsondewnpnB4.a1: more |