DQRID : D030711.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/07/2003103005/15/20031600Incorrect
05/18/2003180005/28/20031700Incorrect
more
Subject:
SGP/EBBR/E27 - Reference T Sensor Failure
DataStreams:sgp5ebbrE27.b1, sgp30ebbrE27.b1, sgp15ebbrE27.b1
Description:
The reference T sensor was not working much of the time, affecting 
all other temperature sensors.  Sensible and latent heat fluxes
were incorrect when this occurred.
Suggestions: 
No recomputation of the fluxes is possible in this case.
Measurements:sgp5ebbrE27.b1:
  • temp_reference
  • temp_air_bottom
  • temp_air_top
more
sgp15ebbrE27.b1:
  • temp_air_left
  • temp_reference_rr
  • temp_air_right
more
sgp30ebbrE27.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_reference
  • sensible_heat_flux
  • bowen_ratio
  • latent_heat_flux
more