DQRID : D131231.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/15/2007000011/20/20070738Suspect
more
Subject:
FKB/SKYRAD/M1 - IRT bias
DataStreams:fkbskyrad60sM1.b1
Description:
Measurements of sky temperature, especially those <250K, were positively biased compared 
with AERI because there was no compensation for the reflectivity of the gold mirror. The 
problem was corrected by changing the IRT emissivity from 1.000 to 0.987.

Use sky temperature measurements less than 230K with caution. Biases as large as 30K have 
been observed when the actual temperature, as measured by AERI, is less than 210 K.
Suggestions: 
Measurements:fkbskyrad60sM1.b1:
  • sky_ir_temp_min
  • sky_ir_temp
  • sky_ir_temp_max
more