Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/02/2008 | 1330 | 05/21/2008 | 1730 | Incorrect |
Subject: | SGP/MFRSR/E22 - Shadowband Misalignment |
DataStreams: | sgpmfrsrE22.b1, sgpmfrsrE22.a0, sgpmfrsrlangleyE22.c1, sgpmfrsrlangplotE22.c1, sgpmfrsrE22.00 |
Description: | A shading problem is evident. It began as a morning issue, but flopped over to an afternoon issue after the first attempt to aligning the instrument on 3/26. Another attempt on 4/23 moved the problem back to morning. A final attempt on 5/21 resolved the problem. |
Suggestions: | Because the shading issue flops between morning and afternoon, interested users will need to manually remove affected data. Contact instrument mentor for help identifying affected periods. |
Measurements: | sgpmfrsrlangplotE22.c1:
sgpmfrsrlangleyE22.c1:
sgpmfrsrE22.b1:
sgpmfrsrE22.a0:
sgpmfrsrE22.00:
|