Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/04/1997 | 0000 | 03/20/1997 | 1700 | Suspect |
05/19/1999 | 1300 | 06/08/1999 | 2000 | Suspect |
08/14/2000 | 1000 | 04/26/2001 | 1700 | Suspect |
05/31/2009 | 2300 | 01/27/2010 | 1500 | Suspect |
Subject: | SGP/QCRAD/E7 - Tc/Td bad/missing/noisy |
DataStreams: | sgpqcrad1longE7.c2, sgpqcrad1longE7.s2, sgpqcrad1longE7.c1, sgpqcrad1longE7.s1 |
Description: | Case and dome temperatures for longwave fluxes are missing, bad, or noisy during this period corresponding to additional noise in the longwave fluxes. Some checks to the longwave fluxes cannot be performed when Tc/Td are missing. No instrument DQRs exist documenting this problem. |
Suggestions: | Longwave fluxes have higher uncertainties during this time period, use with caution. |
Measurements: | sgpqcrad1longE7.c2: more
sgpqcrad1longE7.s2: more sgpqcrad1longE7.c1: more sgpqcrad1longE7.s1: more |