DQRID : D170224.10
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/04/2005051002/27/20112359Does not affect quality
more
Subject:
TWP/MMCR/C3 - Precipitation Mode Reflectivity Incorrect
DataStreams:twpmmcrspecmomC3.a0, twpmmcrspeccmaskprC3.a0, twpmmcrC3.00, twpmmcrmomC3.b1
Description:
The MMCR's precipitation mode is achieved by switching in one of two rf switches thereby 
intending to add approximately 25 dB of attenuation.  This prevents the receiver and 
computer ADC from saturating. It now appears that the amount of attenuation actually being 
applied varied, and is not accurately known.  The precipitation mode reflectivities values 
may not be quantitatively accurate.

It appears that little attenuation was actually being applied to Mode 4. Mode 4 
reflectivities were consistently larger than Mode 3 by more than 10 dB.  (often unrealistically 
large)
Suggestions: 
The reflectivity values should not be used in a quantitative manner.
Measurements:twpmmcrspeccmaskprC3.a0:
  • Documentation not available
more
twpmmcrmomC3.b1:
  • Reflectivity
  • MinimumDetectableReflectivity
more
twpmmcrspecmomC3.a0:
  • MinimumDetectableReflectivity
  • Spectra
more
twpmmcrC3.00:
  • Raw data stream - documentation not supported
more