DQRID : D131122.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
12/03/2011143712/28/20110733Suspect
03/22/2011120206/14/20112000Suspect
08/02/2011171308/02/20112100Suspect
08/29/2012170206/02/20131100Suspect
more
Subject:
SGP/WSACR/C1 - Reprocess: Intermittent missing spectra data
DataStreams:sgpwsacrspeccmaskxpolC1.a0, sgpwsacrspeccmaskcopolC1.a0
Description:
During this period there are times when the spectra ingest and cloud masking processing 
failed, due to problems in matching raw spectra files with the appropriate raw moments 
file. It is believed that many of these remaining raw spectra files can be properly ingested 
when reprocessing is done, although there are cases where no valid moments data exist.
Suggestions: 
Reprocessing will be done to match the remaining raw spectra files to appropriate raw 

moments files and create ingested and masked spectra data whenever possible.
Measurements:sgpwsacrspeccmaskcopolC1.a0:
  • alt
  • signal_to_noise_ratio
  • velocity_bins
  • base_time
  • time_offset
  • lat
  • spectral_width
  • time
  • elevation
  • spectra
  • range
  • mean_doppler_velocity
  • azimuth
  • reflectivity
  • lon
  • locator_mask
more
sgpwsacrspeccmaskxpolC1.a0:
  • elevation
  • lon
  • locator_mask
  • time_offset
  • azimuth
  • base_time
  • lat
  • reflectivity
  • time
  • alt
  • range
  • spectral_width
  • mean_doppler_velocity
  • velocity_bins
  • signal_to_noise_ratio
  • spectra
more

Close this window