DQRID : D140127.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/16/2013163112/18/20131938Does not affect quality
more
Subject:
SGP/SIRS/E37 - Reprocessed: Incorrect LW calibration coefficients
DataStreams:sgpsirsE37.b1
Description:
During the time range specified the UIR and DIR serial numbers were correct but incorrect 
calibration coefficients were applied in the datalogger.  

up_long_hemisp (SN# 30834F3) 
  wrong k1 cal :0.26431 W/(m^2*uV)
  correct k1 cal: 0.2667 W/(m^2*uV)

down_long_hemisp (SN# 30835F3) 
  wrong k1 cal :0.2384 W/(m^2*uV)
  correct k1 cal: 0.2457 W/(m^2*uV)
Suggestions: 
Data were reprocessed in February 2014.
Measurements:sgpsirsE37.b1:
  • down_long_netir
  • down_long_hemisp_shaded_max
  • down_long_hemisp_shaded_std
  • down_long_hemisp_shaded_min
  • up_long_netir
  • down_long_hemisp_shaded
  • up_long_hemisp_min
  • up_long_hemisp_std
  • up_long_hemisp_max
  • up_long_hemisp
more