Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/26/2013 | 0000 | Open Ended | 0000 | Does not affect quality |
Subject: | SGP/MET/E32 - Temperature/humidity sensor failed a 6-month field calibration check |
DataStreams: | sgpmetE32.b1 |
Description: | The temperature/humidity sensor has not been calibrated since 8/26/2013. The relative humidity reading failed a 6-month field calibration check on 11/4/2013 (read high), but has passed all subsequent field calibration checks. In general, the relative humidity may have been subject to drift during this time. The manufacturer characterizes sensor drift at <1% / year. |
Suggestions: | Please contact the mentor for specific information regarding the field calibration check results, if necessary. |
Measurements: | sgpmetE32.b1: more
|