DQRID : D000531.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/17/1995220007/24/19952300Incorrect
more
Subject:
SGP/EBBR/E13 - failure of sensors
DataStreams:sgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp5ebbrE13.00, sgp30ebbrE13.b1
Description:
A lightning strike to the central cluster area shortly after 0800 GMT
on July 17 caused failure of several EBBR sensors: both humidity probes,
the barometer, soil heat flux #3, soil moisture # 1 and the wind
direction.
These failed sensors caused sensible, latent, and average soil heat flux
to be incorrect until site operations performed maintenance on July 24th.

Site Operations found a loose connection from soil moisture probe #1, 
removed barometer SN 6578 and replaced it with SN 6507, removed soil heat 
flux sensor #3 with SN 923022 and replaced it with SN 933199, repositioned 
the wind direction sensor - which was rotated approximately ninety degrees 
clockwise from its proper position, and removed the right humidity probe 
SN 460412 and replaced it with SN 460428.
Suggestions: 
Measurements:sgp15ebbrE13.b1:
  • temp_trh_left_rr
  • rh_left_mv
more
sgp5ebbrE13.00:
  • Raw data stream - documentation not supported
more
sgp5ebbrE13.b1:
  • rh_top_fraction
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
more
sgp30ebbrE13.b1:
  • bowen_ratio
  • temp_trh_top
  • sensible_heat_flux
  • rh_top_fraction
  • latent_heat_flux
  • vapor_pressure_bottom
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
more

Close this window