Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/01/2000 | 0000 | 11/30/2000 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated Data Quality - November 2000 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | DQR DESCRIPTION: Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the November 2000 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: #5323 TIPT Replaced sensor with high bias RELH Current: #5332 MEDI Monthly QA indicates 5% high bias Added: None Resolved: #5293 CATO Replaced sensor with 5% high bias #5316 WEBB Replaced suspect sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5297 BREC Under-reported rain event Added: None Resolved: None TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5178 MADI Replaced suspect sensor #5281 FTCB Repaired lose wire TB10 Current: #5216 PUTN Sensor erratic and dropping to as low as -17.2 C Added: None Resolved: #5282 FTCB Repaired lose wire TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: #5283 FTCB Repaired lose wire TB05 Current: #5215 PUTN Sensor erratic and dropping to as low as -87.5 C Added: None Resolved: #5284 FTCB Repaired lose wire TS30 Current: #5301 WASH 9 C warm bias Added: None Resolved: #5285 FTCB Repaired lose wire ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #5294 A166 Replaced bad sensor RAIN Current: None Added: None Resolved: #5319 A182 Replaced corroded switch #5324 A151 Replaced bad switch #5325 A156 Replaced corroded switch TS05 Current: None Added: None Resolved: #5326 A182 Replaced gopher-damaged sensor TS10 Current: None Added: None Resolved: #5267 A111 Replaced sensor with 2 C cool bias TS15 Current: None Added: None Resolved: #5318 A167 Replaced sensor found chewed in half TS30 Current: None Added: None Resolved: #5299 A159 Replaced erratic sensor #5300 A182 Replaced erratic sensor #5334 A167 Replaced sensor found chewed in half ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |