Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/01/2000 | 0000 | 12/31/2000 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated Data Quality - December 2000 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the December 2000 Oklahoma Mesonet data. Notes: 2 ice storms in December caused many QA problems in the Mesonet. The storm that occurred on Christmas day was the most severe. That particular event caused the wind sensors to be frozen in place at 84 stations for anywhere from 1 to 11 days straight! In addition, the ice coated temperature and RH shields, pyranometers, and rain gauges. The ice also made roads impassable for techs who tried to repair communi- cation links that were knocked out due to ice damage. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5332 MEDI Monthly QA indicates 5% high bias #5355 ERIC Sensor frequently drops to 0% Added: None Resolved: None WDIR Current: #5344 SKIA Sensor stuck at 360 Added: None Resolved: None WSPD Current: #5392 ACME Sensor reported gust to over 35 m/s during ice storm Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: #5394 SEIL Sensor reporting 80% low Resolved: None RAIN Current: #5396 NORM Gauge under-estimated during precip event #5397 MEDF Gauge stuck at 0 during precip event #5398 CLOU Gauge stuck at 0 during precip event Added: None Resolved: #5297 BREC Replaced bad switch #5354 LANE Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: None Added: #5402 MAYR 3 C cool bias Resolved: #5216 PUTN Repaired lose wire on mux TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: None TB05 Current: None Added: None Resolved: #5215 PUTN Repaired lose wire on mux TS30 Current: None Added: None Resolved: #5301 WASH Replaced sensor with warm bias ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5395 A150 Sensor recorded no tips during snow melt Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |