DQRID : D010427.9
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/24/1999044501/25/20011531Incorrect
more
Subject:
SGP EBBR E19 - E19 EBBR Soil Heat Flow #1 Sign Reversed
DataStreams:sgp30ebbrE19.b1, sgp15ebbrE19.b1
Description:
The sign was reversed (heat flow plate #1 was installed upside down), causing incorrect 
measurements, as indicated.

The average soil heat flow can be recalculated by using an average of soil sensor sets 
2-5.  The recalculated average soil heat flow can then be used to recalculate latent and 
sensible heat fluxes.
Suggestions: 
Measurements:sgp30ebbrE19.b1:
  • surface_soil_heat_flux_avg
  • soil_heat_flow_1
  • sensible_heat_flux
  • latent_heat_flux
  • corr_soil_heat_flow_1
more
sgp15ebbrE19.b1:
  • soil_heat_flow_1_mv
more