DQRID : D010703.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/01/2001000005/31/20012359Does not affect quality
more
Subject:
SGP/OKM - Overview of Automated Data Quality - May 2001
DataStreams:sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1
Description:
Below is an overview from Chris Fiebrich, the Mesonet QA manager
of the automated quality assurance results for the May 2001
Oklahoma Mesonet data.


==============================================================
Notes:

Rotations of the wind speed sensors are coming to a close.  Most
all Mesonet sites have had their nose cones replaced.
Pyranometers are now beginning to be rotated statewide.  Most
stations should have newly calibrated pyranometers by the end
of the summer.

===============================================================

TAIR    Current:        None
        Added:          None
        Resolved:       None

RELH    Current:        #5639 NINN Sensor reporting many small
                              spikes and dips not observed at
                              nearby A122
                        #5707 ALTU Sensor stuck at 10-15%
        Added:          None
        Resolved:       None  
 
WDIR    Current:        None
        Added:          None
        Resolved:       #5590 BURB Repaired erroneous WDIR by
                              fixing TA15 port

WSPD    Current:        None 
        Added:          None
        Resolved:       #5673 CALV Replaced sensor with noisy
                              bearings

PRES    Current:        None
        Added:          None
        Resolved:       #5644 CLAY Replaced bad barometer        
                        
SRAD    Current:        None
        Added:          None
        Resolved:       None

RAIN    Current:        #5666 GOOD Gauge missed rain event
        Added:          None 
        Resolved:       #5662 BURB Replaced bad switch
                        #5698 CLAY Replaced bad switch

TA9M    Current:        #5658 MIAM Sensor reporting 20 C cool bias
        Added:          None
        Resolved:       None

WS2M    Current:        None
        Added:          None 
        Resolved:       #5664 MARE Replaced sensor with noisy bearings 
                        #5670 EUFA Replaced sensor with noisy bearings
                        #5676 CALV Replaced sensor with noisy bearings
                        #5685 CLAY Replaced sensor with dirty bearings

TS10    Current:        None
        Added:          None
        Resolved:       #5589 BURB Repaired erratic readings by fixing
                              TA15 port

TB10    Current:        #5665 APAC Sensor reporting 10 C warm bias
        Added:          None
        Resolved:       None
                  
TS05    Current:        None
        Added:          None
        Resolved:       None

TB05    Current:        None
        Added:          None
        Resolved:       None

TS30    Current:        None
        Added:          None
        Resolved:       None


----------------------------------------------------------------
                                ARS QA REPORT
----------------------------------------------------------------

TAIR    Current:        None 
        Added:          None
        Resolved:       None

RELH    Current:        None 
        Added:          None 
        Resolved:       None

SRAD    Current:        None
        Added:          None
        Resolved:       None

RAIN    Current:        #5669 B123 Gauge reported rain in 
                              excess of 8 inches
        Added:          None
        Resolved:       None
                        
TS05    Current:        None
        Added:          None
        Resolved:       None

TS10    Current:        #5671 A125 New sensor (installed via 
                              trouble ticket #5634) is also 
                              reporting erratic obs
        Added:          None
        Resolved:       #5634 A125 Replaced bad sensor

TS15    Current:        None
        Added:          None
        Resolved:       None

TS30    Current:        None
        Added:          #5727 A135 Monthly QA indicates 4 C cool bias
        Resolved:       None

========================================================================

LEGEND
TAIR    Air Temperature measured at 1.5 meters
RELH    Relative Humidity measured at 1.5 meters
WDIR    Wind Direction measured at 10 meters
WSPD    Wind Speed measured at 10 meters
PRES    Pressure
SRAD    Incident Solar Radiation
RAIN    Rainfall
TA9M    Air Temperature measured at 9 meters
WS2M    Wind Speed measured at 2 meters
TS10    Soil Temperature measured at 10 cm under native sod
TB10    Soil Temperature measured at 10 cm under bare soil
TS05    Soil Temperature measured at 5 cm under native sod
TB05    Soil Temperature measured at 5 cm under bare soil
TS15    Soil Temperature measured at 15 cm under native sod
TS30    Soil Temperature measured at 30 cm under native sod

======================================================================
Suggestions: 
Measurements:sgp05okmX1.b1:
  • srad
  • wspd_2m
  • wspd_sigma
  • rh
  • wvec_10m
  • tdry_1_5m
  • prec_amt
  • wdir_sigma
  • wdir_10m
  • wspd_10m
  • tdry_9m
  • wspd_max
  • pres
more
sgp05okmX1.a1:
  • prec_amt
  • wvec_10m
  • pres
  • wspd_sigma
  • wdir_10m
  • tdry_1_5m
  • wspd_10m
  • wspd_max
  • wspd_2m
  • rh
  • tdry_9m
  • srad
  • wdir_sigma
more
sgp15okmX1.b1:
  • tbare10
  • tsoil30
  • tsoil10
  • tbare5
  • tsoil5
more
sgp15okmX1.a1:
  • tsoil5
  • tsoil30
  • tsoil10
  • tbare5
  • tbare10
more