SGP/EBBR/E25 - Reprocess: Soil Heat Flow #5 Negative Offset
DataStreams:sgp30ebbrE25.b1
Description:
Soil heat flow 5 was either too large negative or negative when it should have been 
positive; the cause of the negative offset is unknown, but is often the result of a failed 
J-panel over-voltage protection device.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(q + e + ave_shf)
Suggestions: 
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_avg
  • soil_heat_flow_5
  • sensible_heat_flux
  • corr_soil_heat_flow_5
  • surface_soil_heat_flux_5