Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/01/2002 | 0000 | 11/08/2002 | 1900 | Incorrect |
Subject: | SGP/SIRS/E10 - Noisy UIR |
DataStreams: | sgpsirs60sE10.a1, sgpsirsE10.b1, sgpsirsE10.a2 |
Description: | Upwelling Infrared irradiance signals noisy resulting from problems with pyrgeometer signal cable connections. |
Suggestions: | It may be possible to use coinicident measurements of SIRS Downwelling Infrared (DIR) and EBBR Net radiation to estimate the upwelling longwave irradiance during this period. Results will have greater measurement uncertainty than properly functioning SIRS pyrgeometer. It may be possible to use coinicident measurements of SIRS Downwelling Infrared ( DIR) and EBBR Net radiation to estimate the upwelling longwave irradiance during this period. Results will have greater measurement uncertainty than properly functioning SIRS pyrgeometer. It may be possible to use coinicident measurements of SIRS Downwelling Infrared ( DIR) and EBBR Net radiation to estimate the upwelling longwave irradiance during this period. Results will have greater measurement uncertainty than properly functioning SIRS pyrgeometer. |
Measurements: | sgpsirs60sE10.a1: more
sgpsirsE10.b1: more sgpsirsE10.a2: more |