DQRID : D030115.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
09/18/2002121009/19/20020245Incorrect
more
Subject:
SGP/EBBR/E13 - AEM Jung between Home Positions
DataStreams:sgp5ebbrE13.b1, sgp30ebbrE13.b1, sgp15ebbrE13.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
inbetween home positions, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Suggestions: 
There is no work-around to this problem.
Measurements:sgp15ebbrE13.b1:
  • temp_air_right
  • temp_air_left
more
sgp5ebbrE13.b1:
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_top
  • temp_trh_bottom
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
more
sgp30ebbrE13.b1:
  • bowen_ratio
  • temp_trh_top
  • sensible_heat_flux
  • rh_top_fraction
  • temp_air_bottom
  • latent_heat_flux
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
more