Subject: | SGP/ECOR/E10 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data |
DataStreams: | sgp30ecorE10.b1
|
Description: | Due to system clock instability on ECOR computers their system time is adjusted
approximately once per hour; sometimes this adjustment leads to backward time jumps over midnight,
into the previous day. In this case all the data based on CO2/H2O measurements might be
erroneously marked as bad. |
Suggestions: | Correct data may be restored by reprocessing raw data (sonic and IRGA, 00 level) with
current ECOR processing program (version 1.9 or later). |
Measurements: | sgp30ecorE10.b1: - cvar_uc
- cvar_qc
- var_q
- cp
- n_good_c
- mean_c
- cvar_wq
- cvar_uq
- cvar_rot_vq
- var_c
- skew_q
- n_spk_c
- cvar_rot_vc
- real_cp
- mr
- cvar_vc
- lv
- cvar_tc
- n_bad_c
- real_mr
- n_spk_q
- mean_spk_c
- skew_c
- mean_spk_q
- cvar_rot_uq
- cvar_vq
- real_rho
- cvar_tq
- cvar_rot_wq
- lv_e
- n_bad_q
- cvar_rot_uc
- fc
- n_good_q
- real_lv
- cvar_rot_wc
- cvar_wc
- mean_q
more
|