PYE/ECOR/M1 - Reprocessed: Wind direction offset corrected
DataStreams:pye30ecorM1.b1
Description:
The SMET wind direction was consistently 15 to 20 degrees larger than the wind direction 
determined by the ECOR. The ECOR was mistakenly aligned to magnetic north during this 
period.

The magnetic declination is 14 deg. 58 min., which explains most of the difference.

The ECOR data for this period were reprocessed in November 2006 to add 15 degrees to the 
wind direction.  No other changes were made to the data. The reprocessed data were 
archived in January 2007.
Suggestions: 
Retrieve the reprocessed data for use in data analysis.