DQRID : D060425.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/25/2006210006/20/20061730Incorrect
03/03/2006000005/10/20061130Incorrect
more
Subject:
SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp5ebbrE27.b1, sgp30ebbrE27.b1, sgp15ebbrE27.b1
Description:
The left T/RH probe temperature sensor was spiking some of the time during these periods. 
Therefore, sensible and latent heat fluxes were incorrect during parts of the periods as 
well.
Suggestions: 
Periods of the left sensor spiking can be seen by looking at the 15 minute data.  Do 

not use 30 minute sensible and latent heat fluxes during 30 minute periods that include 
those 15 minute periods.
Measurements:sgp5ebbrE27.b1:
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
more
sgp15ebbrE27.b1:
  • temp_trh_left_rr
more
sgp30ebbrE27.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_trh_top
  • sensible_heat_flux
  • bowen_ratio
  • latent_heat_flux
  • temp_trh_bottom
more

Close this window