Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/22/2006 | 1030 | 05/31/2006 | 0030 | Suspect |
Subject: | SGP/EBBR/E8 - Sensible and Latent Heat Flux Suspect |
DataStreams: | sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | The left humidity sensor produced large spikes frequently. This resulted in incorrect measurements of vapor pressure gradient and thus calculations of sensible and latent heat flux. |
Suggestions: | |
Measurements: | sgp5ebbrE8.b1: more
sgp15ebbrE8.b1: more sgp30ebbrE8.b1: more |