DQRID : D090213.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/16/2008000012/28/20082359Suspect
more
Subject:
HFE/SKYRAD/M1 - IRT bias
DataStreams:hfeskyrad60sM1.b1
Description:
The sky temperatures exhibited a positive bias compared to AERI, especially when < 230K. 
This is indicative of an incorrect emissivity setting (to compensate for the gold mirror) 
or a poor calibration. A similar problem with the same instrument occurred during the FKB 
deployment that was attributed to water vapor.
Suggestions: 
Measurements:hfeskyrad60sM1.b1:
  • sky_ir_temp_max
  • sky_ir_temp
  • sky_ir_temp_min
more